• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.041 seconds

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

A STUDY ON THE PREDICTION OF GROUNDWATER CONTAMINATION USING THE GIS IN HWANAM 2 SECTOR, GYEONGGI PROVINCE, KOREA (GIS를 이용한 경기도 화남2지구의 지하수오염 예측에 관한 연구)

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.4
    • /
    • pp.267-285
    • /
    • 2001
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters,such as structural lineament density and landuse, into conventional DRASTIC medal, and to predict the potential of groundwater contamination using GIS in Whanam 2 Area, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament denisity affects to the behavior of goundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Composite contamination map was achieved as a final result by comparing modified DRASTIC potential and the amount of generation load of several contaminant sources logically. The result could suggest the predictability of the area of contamination potrntial in the respects of hydrogeological aspect and water quality.

  • PDF

Monitoring Technique and Device of Surface Contamination for Line-Post Insulator (지지애자의 표면오염 모니터링 기술 및 장치)

  • Kil, Gyung-Suk;Park, Dae-Won;Jung, Kwang-Seok;Kim, Sun-Jae;Seo, Dong-Hoan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

Groundwater Quality and Contamination Characteristics Associated with Land Use in Ulsan Area (울산지역 토지이용도에 따른 지하수 수질 및 오염특성)

  • Lee, Byeong-Dae;Yun, Uk;Sung, Ig-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.78-91
    • /
    • 2007
  • The groundwater chemistry is heavily influenced by land use. This study has investigated the groundwater quality and contamination characteristic associated with land use. Contamination index ($C_d$) was estimated for evaluating and areal distribution of groundwater contamination degree. Groundwater samples collected from 216 locations in the study area show great variability in chemical composition. Electrical conductance ranges from 100 to $31,360\;{\mu}S/cm$. The pH values are between 4.6 (acidic) and 8.57 (weak alkaline). The water types predominantly represent the $Ca-HCO_3$ and $Ca-Na-HCO_3$ types, whereas, in the residential and business areas, the water type is shifted to (Na, Ca)-Cl type with rich concentration of Cl. The $C_d$ values of the study area range from 1.1 to 117.6 with a mean of 9.56.

Source Identification of Heavy Metal Contamination at an Industrial Complex Established Using Construction Wastes (건설폐기물을 성토재로 사용한 산업단지에서의 중금속 오염 원인 규명)

  • JOO, Gwonho;KIM, Kibeum;NAM, Kyoungphile;JUNG, Jae-Woong;Moon, Seheum;CHOI, Yongju
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2018
  • This paper is aimed at source tracking of soil heavy metal contamination at a site established by reusing construction wastes. The soil heavy metal concentration at the study site peaked at a depth range of 5-10 m. Column studies were conducted to investigate the possibility of the contamination scenario of infiltration of stormwater carrying heavy metals of ground origin followed by selective heavy metal accumulation at the 5-10 m depth range. Almost all amount of lead, zinc, cadmium, and nickel introduced to the columns each packed with 0-5 m or 5-10 m field soil were accumulated in the column. The very poor heavy metal mobility in spite of the weak association of the heavy metals with the soil (characterized by a sequential extraction procedure) can be attributed to the high pH (10-11) of the construction wastes. From the results, the heavy metal contamination of the subsurface soil by an external heavy metal source was determined to be very unlikely at the study site. The column study applied in the current study is expected to be a useful methodology to present direct evidence of the contaminant source tracking at soil contamination sites.

Hydrochemical Characteristics of Groundwater in an Area Affected by Pig Carcass Burial: Leakage Detection (돼지사체 매몰지역 지하수의 수지구화학 특성: 침출수 누출 판단)

  • Oh, Junseop;Kim, Ho-rim;Lee, Jeong-Ho;Kim, Kyoung-ho;Choi, Kwang-jun;Kim, Hyeon-Koo;Yun, Seong-Taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.30-40
    • /
    • 2018
  • To evaluate potential impacts of shallow groundwater by the leachate from buried carcass, we investigated hydrochemical characteristics of both leachate and shallow groundwater from monitoring wells and surrounding shallow groundwater wells in an area potentially affected by pig carcass burial. The hydrochemical survey was conducted before and after the relocation of a burial pit. The leachate samples and the groundwater affected by leachate showed the hydrochemistry of $Ca-HCO_3$ type with high $NH_4{^+}$ concentrations, while unaffected groundwater was mostly the $Ca(Na)-Cl+NO_3$ type due to pervasive impacts from agrochemicals. The results of factor analysis on hydrochemical data showed the followings: 1) contamination of groundwater from agro-livestock farming and livestock burial are coexisting in the study area, 2) among ionic species, $HCO_3{^-}$, $NH_4{^+}$, $NO_3{^-}$ and Mn are very useful to differentiate the groundwater contamination from leachate, and 3) groundwater contamination by leachate has been recognized around the monitoring wells even after the relocation of a burial pit, likely due to residual contaminants in surrounding soils. Therefore, it is suggested that continued monitoring of groundwater contamination should be conducted after the relocation of carcass burial pits.

Assessment of microbial contamination levels of elementary school classrooms as foodservice environments (초등학교 교실 급식 환경의 미생물학적 오염도 평가)

  • Kim, Sun-A;Yi, Hae-Chang;Kim, Eun-Mi;Lee, Min-A;Park, Ji-Ae;Kim, Jeong-Weon
    • Korean journal of food and cookery science
    • /
    • v.23 no.3 s.99
    • /
    • pp.321-326
    • /
    • 2007
  • The microbial contamination levels of school classrooms were assessed as foodservice environments for elementary students. Two elementary schools located in Kyunggi-do were selected, and the total plate counts (TPC) and coliforms were measured from the classroom facilities, including the tables, chairs, floors, shelves, doors, as well as the hands of students, and the air of classrooms. The TPC of the classroom facilities were relatively low ranging from 2.30 to 3.79 log CFU/100 cm$^2$. The TPC counts from the hands of serving students and served students, were 6.39 and 5.33 log CFU, respectively, and the TPC counts of the foodservice utensils were <3.00 log CFU/ea before use and 4.77 CFU/ea after use. The air samples of 'empty classrooms during physical education', 'after physical education class', and 'during lunch' showed the contamination levels of 26 CFU/m$^3$,392 CFU/m$^3$, 364 CFU/m$^3$, respectively, suggesting that the microbial levels in the air varies greatly depending on the class activity before foodservice. When the TPCs of the air during lunch were measured from 18 classrooms, the levels ranged from 76 to >2228 CFU/m$^3$. Coliforms were not detected in the classroom facilities; however, air samples of the classrooms showed 1${\sim}$2 CFU/m$^3$. The above results show that classroom air and the hands of students, can have high levels of microbial contamination, which must to be controlled for safer school foodservice.

Comparison of the Bacterial Contamination Rates according to the Urine Collection Methods in Women (여성에서 소변채집방법에 따른 소변검체의 오염율 비교)

  • Jeong Ihn-Sook;Yang Man-Gil;Oh Hyang-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.3
    • /
    • pp.359-368
    • /
    • 1999
  • Background : The purpose of this study was to determine whether cleansing the perineum and urethral meatus and using midstream urine affect the rate of bacterial contamination of urine specimens, and to determine the optimum urine collection method. We studied 41 asymptomatic healthy nursing school students. Women who were menstruating were not excluded from this study. Method : The first and midstream urine samples were collected during consecutive urinationsby each woman. The first sample was not a clean-catch specimen, and the second one was a clean-catch specimen. Both specimens were studied by urinalysis and bacterial culture with standard methods. Results : 41 women met the study criteria and 39 successfully completed the study. None of the urine cultures were positive. 68.3% of the non clean-catch first urine cultures, 53.7% of the non clean-catch midstream cultures, 33.3% of the first clean-catch urine culteres and 30.8% of the midstream clean-catch urine were found to be contaminated. There was a significant difference in the bacterial contamination rates between the first and midstream urine, and the clean-catch and non clean-catch urine(p=0.035, p =0.001 respectively). On urinalysis, 7.3% of the non clean-catch first urine, 7.3% of the non clean-catch midstream urine, 2.6% of the clean-catch first urine and 2.6% of clean-catch midstream urine were found to be above grade 2. Conclusions : According to our results, the bacterial contamination rate was the lowest in midstream and clean catch urine specimens. Threrfore it is recommended that the midstream clean-catch technique is the standard practice for collecting urine specimens for bacterial culture in women.

  • PDF

A Comparison of Microbial Load on Bare and Gloved Hands among Food Handlers (맨손과 장갑 낀 손의 미생물 오염도 비교)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.298-305
    • /
    • 2011
  • Objectives: There has been a great amount of controversy in the food industry over the effectiveness of using gloves. The objectives of this study were to examine the microbial contamination of food handlers' hands and determine if using gloves could ensure safe handling of foods. Methods: Samples were collected through the glove-juice method from the bare and gloved hands of food handlers at work and were analyzed for the presence of aerobic plate counts, total coliform, fecal coliform, Escherichiacoli, Staphylococcus aureus, and Salmonella spp. Microbiological testing was conducted according to the Food Code of Korea. Results: Microbial contamination was consistently higher with bare hands than with gloved hands, although the microbial loads on both hands increased over time. Under certain conditions, there were significant differences between the bacterial loads on bare and on gloved hands (p<0.05). E. coli, S. aureus, and Salmonella spp. were still alive on both bare and gloved hands at the time the food handlers finished their work. Conclusions: Wearing gloves was associated with a marked reduction of bacterial contamination of the hands. However, the practice of continuously wearing gloves during food handling increases the potential for cross-contamination of bacteria. The findings of this study emphasize the need for a rational use of gloves, and strict adherence to hand hygiene compliance among food handlers.

Contamination Status and Characteristics of Persistent Organochlorine Pesticides in the Saemangeum Environment (새만금 해양환경에서의 잔류성 유기염소계 농약의 분포 및 특성)

  • Hong, Sang-Hee;Shim, Won-Joon;Li, Dong-Hao;Yim, Un-Hyuk;Oh, Jae-Ryoung;Kim, Eun-Soo
    • Ocean and Polar Research
    • /
    • v.28 no.3
    • /
    • pp.317-329
    • /
    • 2006
  • To assess the contamination status of organochlorine pesticides in the marine environment of Saemangeum, surface seawater and sediments were collected and analyzed. Organochlorine pesticides were widely distributed in the Saemangeum environment, with DDT, HCH and endosulfan II contamination being particularly prevalent. The overall concentrations of DDTs, HCHs, and endosulfan II in surface seawater were in the rage of 0.03-0.65ng/l (mean value: 0.36ng/l), 1.31-4.54ng/l (2.63 ng/l), and not detected (ND)-0.96ng/l (0.49ng/l), respectively. Among the target organochlorine pesticides, endosulfan II showed the hi띤est level at the river mouth flowing into the Saemangeum. Additionally, its negative gradient from the rivers to the outside and a good correlation with $NO_3^-$ indicate that endosulfan ll inflows to the Saemangeum through the river; this conclusion is also supported by the elevated levels of endosulfan II in sediments at the river mouth. In sediment, the concentration of DDTs, HCHs, CHLs, and endosulfan II were in the range of 0.05-1.96 ng/g, 0.03-0.31ng/g, 0.01-0.13ng/g, and ND-0.62ng/g, respectively. Levels of contamination in Saemangeum are relatively lower than the median concentrations previously observed at the Korean coastal regions and sediment quality guidelines suggested by NOAA (Long et at. 1995).