• Title/Summary/Keyword: Contaminated air

Search Result 326, Processing Time 0.027 seconds

Study on HVAC System in Nuclear Facility (원자력시설의 공기조화 시스템 고찰)

  • 백상열;송웅섭;오연우;주용선;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.503-508
    • /
    • 2003
  • Heating, Ventilation and hir Conditioning (HVAC) system in nuclear facility should be equipped and constructed more stable and allowable than that in common facility. The purpose of HVAC system is the maintenance of optimum working environment, the protection of worker against a contaminated air and the prevention of atmospheric contamination due to a outward ventilation, etc.. The basic scheme of a safety operation of nuclear facility is to prevent the atmospheric contamination even in low level. The adaptability of HVAC system should be taken into account in the design stage so that it is possible to modify the system which is in operation. In this study, the design requirements of HVAC system in nuclear facility and the HVAC systems in foreign countries are reviewed, and the results can be utilized in the design of HVAC system in nuclear facility.

  • PDF

CO2 sequestration and heavy metal stabilization by carbonation process in bottom ash samples from coal power plant

  • Ramakrishna., CH;Thriveni., T;Nam, Seong Young;kim, Chunsik;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.74-83
    • /
    • 2017
  • Coal-fired power plants supply roughly 50 percent of the nation's electricity but produce a disproportionate share of electric utility-related air pollution. Coal combustion technology can facilitate volume reduction of up to 90%, with the inorganic contaminants being captured in furnace bottom ash and fly ash residues. These disposal coal ash residues are however governed by the potential release of constituent contaminants into the environment. Accelerated carbonation process has been shown to have a potential for improving the chemical stability and leaching behavior of bottom ash residues. The aim of this work was to quantify the volume of $CO_2$ that could be sequestrated with a view to reducing greenhouse gas emissions and stabilize the contaminated heavy metals from bottom ash samples. In this study, we used PC boiler bottom ash, Kanvera reactor (KR) slag and calcined waste lime for measuring chemical analysis and heavy metals leaching tests were performed and also the formation of calcite resulting from accelerated carbonation process was investigated by thermo gravimetric and differential thermal analysis (TG/DTA).

Removal of heavy metals using waste sludge by biosorptive flotation (폐슬러지를 이용한 흡착·부상 공정에 의한 중금속 제거)

  • Lee Chang-Han;Ahn Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.14 no.7
    • /
    • pp.691-697
    • /
    • 2005
  • Waste sludge may be used to recovery wastewater contaminated with heavy metals. The waste sludge is an inexpensive readily available source of biomass for biosorption with metal-bearing wastewater. The biosorption of heavy metals such as Pb(II), Cu(II), Cr(II), and Cd(II) onto waste sludge was investigated in batch ex­periments and waste sludge loaded heavy metals was separated by dissolved air flotation. The biosorption equi­bria of heavy metals could be described by Langmuir and Freundich isotherms. The adsorption capacity for waste sludge was in the sequence of Pb(II)>Cr(II)>Cu(II)>Cd(II). The system attained equilibrium about 20 min. The Langmuir and Freundlich adsorption model effectively described the biosorption equilibrium of Cu(II) and Cr(II) ions on waste sludge. Maximum adsorption capacity of Cu(II) and Cr(II) were 196.08 and 158.73 mg/g, respectively. Solid-liquid separation efficiencies were kept above $95\%$ on waste sludge loaded heavy metals, and were decreased with pH increasing.

Electrolyzed water cleaning for semiconductor manufacturing

  • Ryoo, Kun-Kul;Kim, Woo-Huk
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.117-119
    • /
    • 2002
  • A semiconductor cleaning technology has been based upon RCA cleaning which consumes vast amounts of chemicals and ultra pure water. This technology hence gives rise to many environmental issues, and some alternatives such as electrolyzed water are being studied. In this work, intentionally contaminated Si wafers were cleaned using the electrolyzed water. The electrolyzed waters were obtained in anode and cathode with oxidation reduction potentials and pH of -1050mV and 4.8, and -750mV and 10.0, respectively. The electrolyzed water deterioration was correlated with $CO_2$ concentration changes dissolved from air. Overflowing of electrolyzed water during cleaning particles resulted in the same cleanness as could be obtained with RCA clean. The roughness of patterned wafer surfaces after EW clean maintained that of as-received wafers. RCA clean consumed about $9\ell$ chemicals, while electrolyzed water clean did only $400m\ell$ HCl or $600m\ell$ $NH_4$Cl to clean 8" wafers in this study. It was hence concluded that electrolyzed water cleaning technology would be very effective for releasing environment, safety, and health(ESH) issues in the next generation semiconductor manufacturing.ring.

  • PDF

An Analysis on Plume Behaviour of Rocket Engine with Ground Condition at High Altitude Engine Test Facility (고공시험설비에서 로켓엔진의 지상시험 플룸 거동 해석)

  • Kim, Seong-Lyong;Lee, SeungJae;Han, YoungMin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.112-115
    • /
    • 2017
  • We analyzed the rocket engine flow to check whether the possibility of the ground test and the equipment safety problems in the high altitude engine test facility. The test condition is that the vacuum chamber is open and the coolant water is injected into the supersonic diffuser. The analysis uses two-dimensional axisymmetry with a mixture of plume, air, and cooling water. As a result, the ground test was possible up to the cooling water flow rate of 200 kg/sec. However, due to the back flow of the initial plume, the vacuum chamber is exposed to high temperature, and at the same time, the inside of the vacuum chamber is contaminated due to the reverse flow of the cooling water. Therefore, sufficient insulation measures and work for pollution avoidance should be preceded.

  • PDF

A CASE REPORT OF TOTAL AVULSED SCALP WITH RIGHT TOTAL EAR (우측이부를 포함한 전두피박이환자의 재이식 치험예)

  • Lee, Yeoul-Hi;Byun, Gi-Jung;Kim, Shin-Ho
    • The Journal of the Korean dental association
    • /
    • v.15 no.2
    • /
    • pp.115-120
    • /
    • 1977
  • Extensive avulsion of the scalp, or stripping of a large area of soft tissue from the skull, is a serious accidnet. The avulsed scalp is often injured otherwise, such as by crushing, tearing, or from multiple laceration. The surrounding skin may be devitalized. Replacement of the scalp is usually followed by necrosis and sloughing within a short time. In such instances, the outer table of the cranium may become sucessively exposed. dry, dead, and affected by osteomyelitis. Hence the securing of early healing to prevent these is of the utmost importance. The successful case of reimplantation of the completely avulsed scalp, which is exposured to air for about 14 hours, is reported, in which there was partial growth of hair afterwards. The avulsed scalp caused by her long hair being caught in a grain belt was contaminated with hairs & dust. Authors treated this 19-year old female patient by split thickness skin graft, intermediate skin graft, full thickness skin graft from her own avulsed scalp.

  • PDF

X-ray micro-imaging of the arsenic absorption of sap flow in xylem vessels of a fern brake (X-ray 영상기법을 이용한 비소 흡수가 고사리 내부 수액 거동에 미치는 영향 연구)

  • Lee, Jin-Pyoung;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.92-95
    • /
    • 2006
  • The global environment is deteriorating at an alarming rate despite of enhanced international environmental regulation. Many studies have been performed to reduce pollutants. Recently, phytoremediation, plant-based technology for the removal of toxic contaminants from soil, water, and air, has been receiving large attention. Arsenic-contaminated soil is one of the major pollutant sources fur drinking water. The fern brake (Pteris erotica) has been reported as a hyper-accumulate arsenic from soils. In this study, we investigated the arsenic absorption effect on sap flow inside xylem vessels of a fern brake. The synchrotron X-ray micro-imaging technique was employed to monitor flow inside the plant non-invasively. The captured phase-contrast X-ray images show both anatomy and transport of water inside the fern brake. The refilling process of water containing arsenic inside the xylem vessels of fern brake's leaves and stems was clearly observed. These results would provide important information needed fur understanding the mechanisms of accumulation, translocation, and transformation of toxic materials in plants.

  • PDF

Analysis of Physical Properties and Total Petroleum Hydrocarbon for Soil Contamination (토양오염 해석을 위한 석유제품 물성 및 TPH 분석)

  • Lim, Young-Kwan;Jeong, Choong-Sub;Han, Kwan-Wook
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.618-623
    • /
    • 2012
  • The significance of soil environment has been gradually increased because of petroleum leak accidents. Comparing with wastewater clean treatments and air pollutant controls, the soil purification requires a long-term process and it is very expensive. In this study, we analyzed the physicochemical properties of total petroleum hydrocarbon (TPH) contaminated in soil. This could be applied to deciding the source of petroleum when a soil contamination accident occurs.

Development of Stable Walking Robot for Accident Condition Monitoring on Uneven Floors in a Nuclear Power Plant

  • Kim, Jong Seog;Jang, You Hyun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.632-637
    • /
    • 2017
  • Even though the potential for an accident in nuclear power plants is very low, multiple emergency plans are necessary because the impact of such an accident to the public is enormous. One of these emergency plans involves a robotic system for investigating accidents under conditions of high radiation and contaminated air. To develop a robot suitable for operation in a nuclear power plant, we focused on eliminating the three major obstacles that challenge robots in such conditions: the disconnection of radio communication, falling on uneven floors, and loss of localization. To solve the radio problem, a Wi-Fi extender was used in radio shadow areas. To reinforce the walking, we developed two- and four-leg convertible walking, a floor adaptive foot, a roly-poly defensive falling design, and automatic standing recovery after falling methods were developed. To allow the robot to determine its location in the containment building, a bar code landmark reading method was chosen. When a severe accident occurs, this robot will be useful for accident condition monitoring. We also anticipate the robot can serve as a workman aid in a high radiation area during normal operations.

An automated determination method of particulate matter on food surface (식품표면에 부착된 미세먼지의 정량법)

  • Park, Sun-Young;Bang, Bong-Jun;Lim, Dayoung;Chung, Donghwa;Lee, Dong-Un
    • Food Science and Industry
    • /
    • v.54 no.1
    • /
    • pp.29-33
    • /
    • 2021
  • Particulate matter (PM) is an air pollutant that causes serious environmental problems in Korea and other countries. The annual average PM10 concentration in Korea is around 40 ㎛/㎥, which is more than twice as high as the WHO recommended standard. When consumed with food, fine PM can pose a risk to humans. However, the risk of fine PM has been focused on the risk of fine PM introduced through the respiratory system. We investigated the quantitative measuring methods of PM10 on food surface to identify possible risk analysis of fine PM. The surfaces of food with artificially contaminated PM10 were observed with a scanning electron microscope(SEM). An automatic object-based image analysis was used to analyze the amount and size distribution of particulate matter contained in SEM micrographs.