• Title/Summary/Keyword: Contaminated Process

Search Result 692, Processing Time 0.027 seconds

Evaluation of the Production Process and Hygienic Management of Fresh-cut Lettuce (신선편이 양상추의 가공환경 및 시설에 대한 위생관리수준 평가)

  • Kim, Dong-Man;Cho, Sun-Duk;Kim, Gun-Hee
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • According to lifestyle changes, the consumers' concern about food also shifts from calories and nutrition to health and convenience. Fresh-cut produce is one of the new turns in the consumption pattern of fruits and vegetables. The increasing demand for it requires processors to make them stable in quality and safe from microorganisms. The results of the evaluation of the production process and hygienic management of fresh-cut lettuce revealed that the facilities used, such as the drainage holes, floors, and door knobs, were severely contaminated with microbes, and that the work equipment, workbenches, landing nets, and centrifuges were highly contaminated. Accordingly, improved production processes and management systems are necessary, as is the implementation of a quality control system from the stage of raw-material purchase to the distribution stage.

Application of PAC-Membrane System for Treating Groundwater Contaminated with Chlorinated Organic Compounds (유기염소화합물로 오염된 지하수를 처리하기 위한 PAC-막분리 공정의 적용)

  • Lim, Joong-Kun;Kang, Min-Su;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.892-899
    • /
    • 2005
  • Groundwater is naturally of excellent microbiological qualify and generally of adequate quality for drinking water use. However, recently, the impact of urbanization and intensification of agricultural production have led to serious deterioration in groundwater quality. The representative SOCs used in this study were trichloroethylene (TCE) and tetrachloroethylene (PCE). Powdered activated carbon (PAC) is widely used for SOCs removal. The overall goal of this study was to demonstrate the feasibility of using a hybrid use of PAC-UF and PAC-MF processes for treating groundwater contaminated with TCE and PCE. The results show that the flux decline rate was lower for the PAC-UF or PAC-MF process than for UF or MF only process. Therefore, applying PAC before UF or MF membrane filtration showed not only enhancing the removal of TCE and PCE, but also reducing membrane fouling.

Microbiological quality and detection of pathogenic microorganisms in slaughtered meat in Seoul area (서울지역에서 도축된 식육의 미생물 오염도 및 병원성 미생물 검사)

  • Kim Ju-Young;Lee Ju-Hyung;Gi No-Jun;Lee Jung-Hak
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.215-223
    • /
    • 2005
  • The bacteria on the surface of slaughtered meat was monitored to investigate the relationships between microbiological quality and sanitation management in slaughter process of cattle and pig. It was conducted to evaluate the microbiological quality on the surface of slaughtered beef and pork in Seoul from January to December 2004. Two hundred and thirty three beef and 233 pork carcasses were surveyed on generic E coli counts and standard plate count for microbiological quality and Salmonella spp, Listeria monocytogenes, Staphylococcus aureus, Clostridium perfringens and E coli O157: H7 as pathogenic microorganisms. The prevalence of the excellent or good grade $(10^4\;CFU/cm^2)$ in beef and pork carcasses were $100\%\; and\;99.2\%$, respectively. The frequency of beef carcasses with less than $10^2\;CFU/cm^2$ of generic I coli counts was $100\%$, while that of pork carcasses was $99.6\%$. Of 233 beef carcasses, $1(0.42\%)$ was contaminated with L monocytogenes and $6(2.58\%)$ with C perfringens. Of 233 pork carcasses, $11(4.72\%),\;2(0.86\%),\;and\;2(0.86\%)$ were contaminated with L monocytogenes, C perfringens, and S aureus, respectively, Salmonella spp and E coli O157:H7 were not detected with all of the beef and pork carcasses. In conclusion, this study emphasized the Importance of relationship between microbiological quality and sanitation management in slaughter process of cattle and pig, in abattoirs.

A Study on the Particle Separation Technology of Contaminated Dredged Sediments (오염 준설퇴적토의 입자분리기술에 관한 연구)

  • Park, Jeong Jun;Hwnag, Soon Gab;Shin, Eun Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.87-94
    • /
    • 2013
  • As sediment contamination problems have recently been raised in Korea, the need for technologies to remove contaminants in sediments has increased. Contaminated sediments in Korea has been annually dredged and treated using processes of coagulation/flocculation, sedimentation on barges, dewatered and dried at prepared site, and then disposed at a landfill site, which is very costly, and only a limited landfill space available in Korea. Contaminants in media containing a high percentage of silt and clay sized particles, typically, are strongly adsorbed on the particles and difficult to remove. Particle separation processes that separate the fine clay and silt particles from the coarser sand and gravel and concentrate the contaminants into a smaller volume of sediment that can be further treated of disposed of, are very effective in the post step processes. In this study are to test the feasibility of treating dredged sediments using a hydrocyclone process, and to estimate design parameters for a pilot scale test. A hydrocyclone was operated to separate larger particles from the sediments. It was found that the particle separation was greatly affected by the solid contents and inlet pressure in the hydrocyclone.

Improvement of Indoor Air Quality by Coating of Indoor Materials of $TiO_2$ Photocatalyst Sol (이산화티탄 광촉매 졸(sol)의 실내환경 코팅에 의한 실내공기질 개선)

  • 양원호;김대원;정문호;양진섭;박기선
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.92-97
    • /
    • 2004
  • Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.

Effect of Impurities on Stress Induced Void Formation in Al-1% Si Conductors

  • Lee, Seong-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.3
    • /
    • pp.12-17
    • /
    • 2001
  • It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal. It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal.

  • PDF

A Study on Optimal Conditions for Washing the Heavy Metal Polluted Soil in Ka-hak Mine (가학광산 중금속 오염토양의 세척 최적조건 연구)

  • Kim, Teayoup;Park, Jayhyun;Park, Juhyun
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.517-526
    • /
    • 2018
  • In order to remove pollutants from the soil in the Ka-hak mine site, this study investigates optimization of the acid washing conditions for the soil. The soil at the site is presumed to be contaminated by diffused heavy-metal-contaminated tailings. The major heavy metal pollutants in the soil are copper, lead, and zinc. Gravels larger than 5mm in size constitute approximately 38% of the soil, and these are the least polluted by heavy metals. On the other hand, it is difficult to reduce the concentration of heavy metals in fine soils, particularly those whose sizes are less than 0.075 mm. The results of the continuous process using a hydro-cyclone show that fine soil particles consisting of at least 20% of the raw soil must be separated before the chemical soil washing process in order to achieve reliable cleaning.

Removal of diesel hydrocarbons by microwave-enhanced soil vapor extraction (Focused on Loss and Kinetic constant for Diesel Hydrocarbons)

  • 김종운;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.223-226
    • /
    • 2004
  • In this paper, removal of diesel hydrocarbons (C$_{10}$-C$_{22}$) for dry and moist soil was investigated so that microwave-enhanced soil vapor extraction(SVE) reduced soil treatment time and raised remediation efficiency. Kinetic constants of diesel hydrocarbons with microwave energy were 7 times on dry soil and 1580 times on moist soil as much as those of SVE process without microwave energy. The diesel removals were 67.7~78.4% for $C_{10}$ and $C_{12}$, and 0~18.5% for $C_{14}$~C$_{22}$ for dry and moist soil with SVE process only. On the other hand, dry soil with microwave-enhanced SVE process showed 89.3~99.4% removal for $C_{10}$ and $C_{12}$ and 35.6~67.0% for hydrocarbons over $C_{14}$. All hydrocarbons(C$_{10}$~C$_{22}$) studied were significantly removed (93.6~99.8%) for moist soil with microwave-enhanced SVE process. Almost all diesel hydrocarbons were usually considered as semi-volatile compounds(SVOCs). Microwave-enhanced SVE process might have a great potential for remediation of soils contaminated with SVOCs.OCs.

  • PDF

Generation of Hazardous Gas and Corrosion Originated from Anaerobic Digestion of Process Water in OCC Recycling Mill (골판지 재활용 공정수의 혐기성 분해에 따른 유해 기체의 생성과 부식)

  • Park, Dae-Sik;Ryu, Jeong-Yong;Song, Bong-Keun;Seo, Yung-Bum;Sung, Yong-Joo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.3
    • /
    • pp.59-65
    • /
    • 2005
  • There are accumulations of remained chemical additives and contaminants in the process water of semi-closed linerboard mill. High temperature of the process water aggravates the anaerobic digestion of contaminated process water and causes the generation of hazardous gases, which are from the biological reaction of varied additives and contaminants. The hydrogen sulfide in the gases easily combine with moisture in the air, and become sulfuric acid, which causes corrosion of paper machinery. This hydrogen sulfide is from the reduction of sulfate ions in the process water, and the sulfate ions are mostly from the alum. We changed the alum to PAC (Poly Aluminum Chloride). The results were preventing generation of hydrogen sulfide, and equivalent sizing effect by the use of PAC.

세라믹 가스센서를 이용한 토양증기추출공정의 배출가스 모니터링 기법 연구

  • 양지원;조현정;이재영;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.250-252
    • /
    • 2002
  • The goals of environmental monitoring are to locate and quantify the significant contamination, estimate the fate and transport, estimate the potential exposure and risks to humans and the environment, and track the performance of various remedial technologies. In this study, ceramic gas sensor system is proposed to enhance the effectiveness of soil vapor extraction (SVE) process by monitoring the effluent gas. SVE is a technique that is widely used to remediate unsaturated soils contaminated with volatile organic contaminants. The sensor response for benzene, toluene, and xylene, the representative effluent gas compositions of SVE process, was evaluated using the proposed sensor system. As a result, it was verified that the response of sensor was increased or decreased very sensitively according to the change of the effluent gas concentration. Besides, the sensor could detect the difference over a wide range of concentration and it was more sensitive in order of xylene, toluene, and benzene. It is expected that this VOC analysis method results in field monitoring costs saying and appropriate immediate action for process control. More detailed experiments are being conducted in our research group.

  • PDF