• Title/Summary/Keyword: Contaminant transport analysis

Search Result 51, Processing Time 0.029 seconds

Characteristics of Groundwater Pollution and Contaminant Attenuation at Waste Disposal Sites (폐기물 매립지 주변의 지하수 오염과 오염물질의 지연 특성)

  • 오석영;전효택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.37-49
    • /
    • 1996
  • The objectives of this study are to investigate the groundwater and surface water contamination, to interpret the attenuation mechanism of contaminant transport, and to find the appropriate contamination indicator. at the two big landfill sites : Nanjido Landfill and Hwasung Landfill. Leachate from the Nanjido, th, Hwasung and the Kimpo waste disposal sites is characterized by high temperature (31.7-40.1$^{\circ}C$), high electric conductivity (14,650-32,800 ${\mu}$S/cm), somewhat higher pH(7.58-8.45) and low Eh (-119.4-20.4 mV), and is enriched in both major (Na$^{+}$, K$^{+}$, Ca$^{2+}$, Mg$^{2+}$, HC $O_3$$^{-}$, Cl$^{-}$) and minor (Mn, Sr$^{2+}$, Ba$^{2+}$, Li$^{+}$, F$^{-}$, Br$^{-}$) ions. Municipal solid waste leachate and industrial waste leachate are effectively discriminated by the content of S $O_4$$^{2-}$, Fe, and heavy metals. The attenuation mechanism of each component was assessed using the chemical analysis. Cl-normalizing process, WATEQ4F simulation, and preceding flownet analysis. Based on the calculation of Contamination Factor, K, Na, Ca, Mg, B, Zn, HC $O_3$, Cl, F, Br and TOC are effective contamination indicators in the Nanjido landfill site, and K, Na, Ca, Mg, B, S $O_4$, HC $O_3$, Cl, F, Br and TOC in the Habsburg landfill site Particularly, TOC is the best contamination indicator in landfill sites influenced by sea water.

  • PDF

A Solute Transport Analysis around Underground Storage Cavern by using Eigenvalue Numerical Technique (고유치 수치기법을 이용한 지하저장공동 주위의 용질이동해석)

  • Chung, Il-Moon;Kim, Ji-Tae;Cho, Won-Cheol;Kim, Nam-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.381-391
    • /
    • 2008
  • The eigenvalue technique is introduced to overcome the problem of truncation errors caused by temporal discretization of numerical analysis. The eigenvalue technique is different from simulation in that only the space is discretized. The spatially discretized equation is diagonized and the linear dynamic system is then decoupled. The time integration can be done independently and continuously for any nodal point at any time. The results of eigenvalue technique are compared with the exact solution and FEM numerical solution. The eigenvalue technique is more efficient than the FEM to the computation time and the computer storage in the same conditions. This technique is applied to the solute transport analysis in nonuniform flow fields around underground storage caverns. This method can be very useful for time consuming simulations. So, a sensitivity analysis is carried out by using this method to analyze the safety of caverns from nearly located contaminant sources. According to the simulations, the reaching time from source to the nearest cavern may takes 50 years with longitudinal dispersivity of 50 m and transversal dispersivity of 5 m, respectively.

Elemental Composition and Source Identification of PM2.5 in Jeju City (제주시 미세먼지(PM2.5)에 함유된 원소의 조성특성 및 오염원)

  • Lee, Ki-Ho;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.543-554
    • /
    • 2018
  • From November 2013 to December 2016, ambient fine particulate matter ($PM_{2.5}$) was sampled in the downtown area of Jeju City, South Korea, which has seen rapid urbanization. The atmospheric concentrations of elements were measured in the $PM_{2.5}$ samples. This study focused on Cd, Cr, Cu, Mn, Ni, Pb, As, Sb, Sn, V, and Zn. The concentrations of Al, Na, K, Fe, Ca, Mg, Sr, and La were also obtained for reference. The objectives of this study were to examine the contributions of these elements to $PM_{2.5}$ concentrations in downtown Jeju City, and to investigate the inter-element relationships and the elemental sources by using enrichment factors and principal components analysis (PCA). A composition analysis showed that the 19 elements constituted 6.65 % of the $PM_{2.5}$ mass, and Na, K, Al, Fe, Ca, Mg, and Zn constituted 98 % of the total ion mass. Seasonal trend analysis for the sampling period indicated that the concentrations of the elements increased from November to April. However, no substantial seasonal variations were found in the concentrations of the elements. The composition ratios of some elements (Cu/Zn, Cu/Cd, Cu/Pb, V/Ni, and V/La) were found to be out of range when compared to the literature from other urban areas. The ratios between the elements and the PCA results showed that local contaminant sources in Jeju City rarely influence the composition of $PM_{2.5}$. This suggests that the major sources of $PM_{2.5}$ in Jeju City may include long-range transport of fine particulate matter produced in other areas.

Analysis of the Hydraulic Head Affected by Stage of Tidal Rivers (감조구역에서 지하수 수두의 거동 해석)

  • 김민환;이재형
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.30-37
    • /
    • 1995
  • In the tidal compartment, the hydraulic head is affected by the stage of tidal rivers. For groundwater or construct works, head variation of groundwater should be considered in zone of this aquifer. A numerical analysis is performed which has an 1-dimemsional explicit finite difference scheme to show the head variation of groundwater with tidal stage and hydraulic conductivity, etc. The stability of the numerical scheme is validated by using the analytic solution. The head variation of groundwater is observed for various tidal amplititude and hydraulic conductivity, mean hydraulic gradient and pumping at any point. The range of influence corresponding to the parameters used in this study is about 60m. This value is not beyond a wave length (equation omitted). There was a pumping at a constant rate out of aquifers affected by tide and not affected by tide. Because pumping head in aquifer affected by tide is short, the expense of electric power is economized in this zone. These results are applicable to trace of contaminant transport, efficient operation of groundwater, and examination of the safety and stability of works in the tidal compartment.

  • PDF

Development of Grid Reconstruction Method to Simulate Drying/Wetting in Natural Rivers (II): Model Application and Comparison (자연하천에서 마름/젖음 처리를 위한 격자재구성 기법의 개발 (II): 모형의 적용 및 비교.검토)

  • Choi, Seung-Yong;Kim, Sang-Ho;Hwang, Jae-Hong;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.11
    • /
    • pp.989-1004
    • /
    • 2009
  • The objective of this study is to examine validation of Grid Reconstruction Method, which is developed to simulate drying/wetting in complex natural rivers with wetting and drying domain areas. To verify application of the developed model, the model was applied to natural rivers with wetting and drying domain areas such as Han river and Nakdong river. The simulation results have shown good agreements with observed data and the results for the developed model were more accurate and improved stability of numerical computation than those of RMA-2 model. If the analysis of contaminant advection-diffusion and sediment transport are performed with the study results, the results can be effectively applied to river flow analysis and ecological hydraulics.

Evaluation of Heavy Metal Sources and Its Transfer and Accumulation to Crop in Agricultural Soils (농경지 토양의 중금속 오염원 및 농작물로의 중금속 전이·축적 평가)

  • Lim, Ga-Hee;Jo, Hun-Je;Park, Gyoung-Hun;Yun, Sung-Mi;Kim, Ji-In;Noh, Hoe-Jung;Kim, Hyun-Koo;Yoon, Jeong-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.3
    • /
    • pp.27-42
    • /
    • 2018
  • It is important to identify the contaminant sources and to evaluate the fate and transport of heavy metals to crops in agricultural lands. This study was conducted to evaluate metal sources and its transfer and accumulation to crop in agricultural soils. Pollution indices were calculated and multivariate analysis was performed to identify metal sources. To evaluate transfer and accumulation of metals to crops, the contents of phytoavailable metals were evaluated by using single extraction method and the correlation between metal content and soil properties was analyzed. Also the BCF was quantitatively evaluated for investigating the metal transition to each crop grown in the research area. As a result, Cr, Ni, and Co were expected to be mainly derived from geologic factors due to weathering of certain parent rocks. The content of nickel in soils of the research area was slightly higher than that of the concern level criteria based on total concentration, but the amount transferred and accumulated in the crops was actually low. Understanding the contamination characteristics by investigating the pollution sources of heavy metals and its transfer and accumulation to crops through various evaluation techniques could provide important information for proper management of the agricultural land.

Field Studios of In-situ Aerobic Cometabolism of Chlorinated Aliphatic Hydrocarbons

  • Semprini, Lewts
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.3-4
    • /
    • 2004
  • Results will be presented from two field studies that evaluated the in-situ treatment of chlorinated aliphatic hydrocarbons (CAHs) using aerobic cometabolism. In the first study, a cometabolic air sparging (CAS) demonstration was conducted at McClellan Air Force Base (AFB), California, to treat chlorinated aliphatic hydrocarbons (CAHs) in groundwater using propane as the cometabolic substrate. A propane-biostimulated zone was sparged with a propane/air mixture and a control zone was sparged with air alone. Propane-utilizers were effectively stimulated in the saturated zone with repeated intermediate sparging of propane and air. Propane delivery, however, was not uniform, with propane mainly observed in down-gradient observation wells. Trichloroethene (TCE), cis-1, 2-dichloroethene (c-DCE), and dissolved oxygen (DO) concentration levels decreased in proportion with propane usage, with c-DCE decreasing more rapidly than TCE. The more rapid removal of c-DCE indicated biotransformation and not just physical removal by stripping. Propane utilization rates and rates of CAH removal slowed after three to four months of repeated propane additions, which coincided with tile depletion of nitrogen (as nitrate). Ammonia was then added to the propane/air mixture as a nitrogen source. After a six-month period between propane additions, rapid propane-utilization was observed. Nitrate was present due to groundwater flow into the treatment zone and/or by the oxidation of tile previously injected ammonia. In the propane-stimulated zone, c-DCE concentrations decreased below tile detection limit (1 $\mu$g/L), and TCE concentrations ranged from less than 5 $\mu$g/L to 30 $\mu$g/L, representing removals of 90 to 97%. In the air sparged control zone, TCE was removed at only two monitoring locations nearest the sparge-well, to concentrations of 15 $\mu$g/L and 60 $\mu$g/L. The responses indicate that stripping as well as biological treatment were responsible for the removal of contaminants in the biostimulated zone, with biostimulation enhancing removals to lower contaminant levels. As part of that study bacterial population shifts that occurred in the groundwater during CAS and air sparging control were evaluated by length heterogeneity polymerase chain reaction (LH-PCR) fragment analysis. The results showed that an organism(5) that had a fragment size of 385 base pairs (385 bp) was positively correlated with propane removal rates. The 385 bp fragment consisted of up to 83% of the total fragments in the analysis when propane removal rates peaked. A 16S rRNA clone library made from the bacteria sampled in propane sparged groundwater included clones of a TM7 division bacterium that had a 385bp LH-PCR fragment; no other bacterial species with this fragment size were detected. Both propane removal rates and the 385bp LH-PCR fragment decreased as nitrate levels in the groundwater decreased. In the second study the potential for bioaugmentation of a butane culture was evaluated in a series of field tests conducted at the Moffett Field Air Station in California. A butane-utilizing mixed culture that was effective in transforming 1, 1-dichloroethene (1, 1-DCE), 1, 1, 1-trichloroethane (1, 1, 1-TCA), and 1, 1-dichloroethane (1, 1-DCA) was added to the saturated zone at the test site. This mixture of contaminants was evaluated since they are often present as together as the result of 1, 1, 1-TCA contamination and the abiotic and biotic transformation of 1, 1, 1-TCA to 1, 1-DCE and 1, 1-DCA. Model simulations were performed prior to the initiation of the field study. The simulations were performed with a transport code that included processes for in-situ cometabolism, including microbial growth and decay, substrate and oxygen utilization, and the cometabolism of dual contaminants (1, 1-DCE and 1, 1, 1-TCA). Based on the results of detailed kinetic studies with the culture, cometabolic transformation kinetics were incorporated that butane mixed-inhibition on 1, 1-DCE and 1, 1, 1-TCA transformation, and competitive inhibition of 1, 1-DCE and 1, 1, 1-TCA on butane utilization. A transformation capacity term was also included in the model formation that results in cell loss due to contaminant transformation. Parameters for the model simulations were determined independently in kinetic studies with the butane-utilizing culture and through batch microcosm tests with groundwater and aquifer solids from the field test zone with the butane-utilizing culture added. In microcosm tests, the model simulated well the repetitive utilization of butane and cometabolism of 1.1, 1-TCA and 1, 1-DCE, as well as the transformation of 1, 1-DCE as it was repeatedly transformed at increased aqueous concentrations. Model simulations were then performed under the transport conditions of the field test to explore the effects of the bioaugmentation dose and the response of the system to tile biostimulation with alternating pulses of dissolved butane and oxygen in the presence of 1, 1-DCE (50 $\mu$g/L) and 1, 1, 1-TCA (250 $\mu$g/L). A uniform aquifer bioaugmentation dose of 0.5 mg/L of cells resulted in complete utilization of the butane 2-meters downgradient of the injection well within 200-hrs of bioaugmentation and butane addition. 1, 1-DCE was much more rapidly transformed than 1, 1, 1-TCA, and efficient 1, 1, 1-TCA removal occurred only after 1, 1-DCE and butane were decreased in concentration. The simulations demonstrated the strong inhibition of both 1, 1-DCE and butane on 1, 1, 1-TCA transformation, and the more rapid 1, 1-DCE transformation kinetics. Results of tile field demonstration indicated that bioaugmentation was successfully implemented; however it was difficult to maintain effective treatment for long periods of time (50 days or more). The demonstration showed that the bioaugmented experimental leg effectively transformed 1, 1-DCE and 1, 1-DCA, and was somewhat effective in transforming 1, 1, 1-TCA. The indigenous experimental leg treated in the same way as the bioaugmented leg was much less effective in treating the contaminant mixture. The best operating performance was achieved in the bioaugmented leg with about over 90%, 80%, 60 % removal for 1, 1-DCE, 1, 1-DCA, and 1, 1, 1-TCA, respectively. Molecular methods were used to track and enumerate the bioaugmented culture in the test zone. Real Time PCR analysis was used to on enumerate the bioaugmented culture. The results show higher numbers of the bioaugmented microorganisms were present in the treatment zone groundwater when the contaminants were being effective transformed. A decrease in these numbers was associated with a reduction in treatment performance. The results of the field tests indicated that although bioaugmentation can be successfully implemented, competition for the growth substrate (butane) by the indigenous microorganisms likely lead to the decrease in long-term performance.

  • PDF

Analysis on the Seepage Behavior of Organic Contaminants in Soil (토양에서 유기화합물질의 침투 거동 연구)

  • Lee, Jun Ho;Han, Sun Hyang;Park, Kap Song
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.489-496
    • /
    • 2013
  • Ground water underlying soil is vulnerable to pollution by organic chemicals through their percolation through the soil system. This study was conducted to provide information on the seepage behavior of organic chemical contaminants in clay, silty and sandy soils. Chloroform, 1,1,1-trichloroethane and trichloroethylene are readily transported through the soil; their percolated mass were 4.6-19.2 percent of the total mass applied. Tetrachloroethylene, 1,2-dichlorobenzene and 1,3-dichlorobenzene were retarded by soils due to sorption. Between 0.6 and 4.8 percent of the material applied to the surface percolated within the experimental period. Carbon tetrachloride was attenuated considerably by passage through soils. Only 0.1-0.4 percent of the mass reached the groundwater. Significant degradation of bromoform was observed. Apparent breakdown of intermediates of the brominated compounds were detected. Transformations of the brominated compounds appear to be the result of both biological and chemical processes. The effect of soil type on the mobility of organic chemical contaminants was considerable. The organic contaminants moved faster in sandy soil than in either clay or silty soils.

Development of response terms for contaminant transport in two-dimensional model for mixing analysis of toxic chemicals in rivers (하천에 유입된 유해화학물질의 혼합 해석을 위한 2차원 오염물질 이동모형 반응항 개발)

  • Shin, Dongbin;Shin, Jaehyun;Seo, Il Won
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.141-154
    • /
    • 2020
  • The accidents of toxic chemical spill into rivers are increasing in recent years due to expansion of heavy industries in Korea. In order to respond to the chemical spills, accident response systems have been established for both main rivers and tributary rivers. However, since these accident response system adopted the water quality models imported from the foreign countries, it is difficult to acquire the model parameters and to calibrate and validate the water quality models. Therefore, this study developed a depth-averaged two-dimensional river water quality model to analyze the behavior of hazardous chemicals in rivers and proposed an efficient simulation execution framework by identifying the significant reaction mechanisms considering the characteristics of the toxic chemicals. The depth-averaged two-dimensional river water quality model CTM-2D was upgraded by adding reaction terms representing mechanisms of the adsorption, desorption, and volatilization of toxic chemicals. In order to verify the model, the analytical solution was compared with the numerical solution, and results showed that the error was less than 0.1%. In addition, the model was applied to a virtual scenario which is a water pollution accident at the confluence of the Nakdong River - Kumho River, and model results showed that an efficient simulation could be carried out by activating only significant reactions which were assessed by the sensitivity analysis.

Surveillance of Newcastle Disease Virus in Chicken Slaughterhouses (닭 도축장에서의 뉴캣슬병 바이러스 오염 실태 조사)

  • Choi, Kang-Seuk;Lee, Eun-Kyoung;Jeon, Woo-Jin;Kwon, Jun-Hun;Lee, Jin-Hwa;Sung, Haan-Woo
    • Korean Journal of Poultry Science
    • /
    • v.38 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • We conducted a 10-month (March to October 2009) surveillance of Newcastle disease virus (NDV) in 13 slaughterhouses in Korea. NDV was isolated in 13.0%, 13.3%, 16.0%, and 10.8% of chicken farms, transport vehicles, hang rooms, and chilling water, respectively. Of NDV isolates from slaughterhouses, 37% were isolated in July. All NDV isolates were determined to be lentogenic viruses by RT-PCR-based pathotyping, and all NDV isolates had the $^{112}GKQGR/L^{117}$ motif at the cleavage site of the F protein. Phylogenetic analysis based on the hypervariable region of the F protein gene classified all 25 NDV isolates examined into genotype I within class II. Of these, 24 were clustered together with the NDV V4 strain, while the remaining isolate was placed in the cluster belonging to the NDV Ulster 2C strain. Our results indicate that lentogenic NDV was a high-frequency contaminant in the serial process of ranging live birds to slaughtering at slaughterhouses.