• 제목/요약/키워드: Contaminant index

검색결과 28건 처리시간 0.025초

가스렌지와 창문위치에 따른 주방 배기성능 예측 (Prediction of the ventilation performance in a kitchen with various locations of gas range and window)

  • 김경환;이재헌;박명식;이대우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

오염원에 의한 지하수 수질의 변화 (Change of Groundwater Quality derived from Contaminant Sources)

  • 배상근
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.75-75
    • /
    • 1995
  • In order to provide for the guidance on groundwater quality monitoring network design and also, to suggest the index to the solution of the contaminated groundwater remediation problems in the lake watershed, it is necessary to analyze the contaminant transport in the groundwater. The solute transport was analyzed in the lake watershed to investigate the behavior of the injected contaminant sources depend on the relationships between the point of contaminant sources and position of the lake. Three hypothetical groundwater flow systems, which is composed of a flow-through lake and two solute sources, were considered. The lakes located in the upper, middle, and lower portions of a watershed respectively. The transported contaminant was numerically simulated for five years by using MT3D contaminant transport model under the three-dimentional steady state conditions. From the above simulations, it can be concluded that the contaminant concentration was high as the contaminant source located at the upper position of a watershed, and the influence of the contaminant injection was large as the solute source located at the lower position. When the injection of contaminant was continued for one year without regard to the position of contaminant source and the lake, the influence of contaminant source was reached to bedrock.

오염원에 의한 지하수 수질의 변화 (Change of Groundwater Quality derived from Contaminant Sources)

  • 배상근
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.461-468
    • /
    • 1995
  • In order to provide for the guidance on groundwater quality monitoring network design and also, to suggest the index to the solution of the contaminated groundwater remediation problems in the lake watershed, it is necessary to analyze the contaminant transport in the groundwater. The solute transport was analyzed in the lake watershed to investigate the behavior of the injected contaminant sources depend on the relationships between the point of contaminant sources and position of the lake. Three hypothetical groundwater flow systems, which is composed of a flow-through lake and two solute sources, were considered. The lakes located in the upper, middle, and lower portions of a watershed respectively. The transported contaminant was numerically simulated for five years by using MT3D contaminant transport model under the three-dimentional steady state conditions. From the above simulations, it can be concluded that the contaminant concentration was high as the contaminant source located at the upper position of a watershed, and the influence of the contaminant injection was large as the solute source located at the lower position. When the injection of contaminant was continued for one year without regard to the position of contaminant source and the lake, the influence of contaminant source was reached to bedrock.

  • PDF

AN ANALYSIS OF THE EFFECT OF HYDRAULIC PARAMETERS ON RADIONUCLIDE MIGRATION IN AN UNSATURATED ZONE

  • Kim, Gye-Nam;Moon, Jei-Kwon;Lee, Kune-Woo
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.562-567
    • /
    • 2010
  • A One-Dimensional Water Flow and Contaminant Transport in Unsaturated Zone (FTUNS) code has been developed in order to interpret radionuclide migration in an unsaturated zone. The pore-size distribution index (n) and the inverse of the air-entry value ($\alpha$) for an unsaturated zone were measured by KS M ISO 11275 method. The hydraulic parameters of the unsaturated soil are investigated by using soil from around a nuclear facility in Korea. The effect of hydraulic parameters on radionuclide migration in an unsaturated zone has been analyzed. The higher the value of the n-factor, the more the cobalt concentration was condensed. The larger the value of $\alpha$-factor, the faster the migration of cobalt was and the more aggregative the cobalt concentration was. Also, it was found that an effect on contaminant migration due to the pore-size distribution index (n) and the inverse of the air-entry value ($\alpha$) was minute. Meanwhile, migrations of cobalt and cesium are in inverse proportion to the Freundich isotherm coefficient. That is to say, the migration velocity of cobalt was about 8.35 times that of cesium. It was conclusively demonstrated that the Freundich isotherm coefficient was the most important factor for contaminant migration.

Polychaete Taxocenes Variability Associated with Sediment Pollution Loading in the Peter the Great Bay (the East Sea/Japan Sea)

  • Belan Tatyana A.;Moschenko Alexander A.
    • Ocean Science Journal
    • /
    • 제40권1호
    • /
    • pp.1-10
    • /
    • 2005
  • Variations in species diversity and abundance of polychaete taxocenes that occurred in 1980-1989 under different contamination levels of bottom sediments were studied in three areas of Peter the Great Bay. The most polluted area was shown to be the Golden Horn Inlet where contaminant contents in the bottom sediments exceed the threshold values of negative biota alterations. Amursky Bay is characterized by a moderate level of contamination, while Ussuriysky Bay has the lowest level of contamination. Pollutant contents vary considerably within the same areas and their separate patches are polluted differently. An integral index characterizing the contamination of bottom sediments is proposed. This index is an average grade of the rank value of contaminant contents in sediments. The index was used to compare the contamination level and data on polychaete species diversity and abundance. The highest species diversity of polychaetes is found in the least affected zones. Monotonous decrease of the species number, as well as decrease in the indices of diversity and evenness, is correlated with pollution level increases. Significant growth of the average polychaete biomass and polychaete density is observed in the case of an increase of contamination from low to moderate levels. Conversely, the biomass and abundance of polychaetes decline following an increase in contamination.

HRT 변경에 따른 호기성 그래뉼 슬러지의 오염원 제거효율에 미치는 영향 (Effects of Different Hydraulic Retention Times on Contaminant Removal Efficiency Using Aerobic Granular Sludge)

  • 김현구;안대희
    • 한국환경과학회지
    • /
    • 제28권8호
    • /
    • pp.669-676
    • /
    • 2019
  • The purpose of this study was to evaluate the effects of different Hydraulic Retention Times (HRTs) on the contaminant removal efficiency using Aerobic Granular Sludge (AGS). A laboratory-scale experiment was performed using a sequencing batch reactor, and the Chemical Oxygen Demand (COD), nitrogen, orthophosphate removal efficiency, AGS/MLSS ratio, and precipitability in accordance with the HRT were evaluated. As a result, the COD removal efficiency was not significantly different with the reduction in HRT, and at a HRT of 6 h, the removal rate was slightly increased owing to the increase in organic loading rate. The nitrogen removal efficiency was improved by injection of influent division at a HRT of 6 h. As the HRT decreased, the MLSS and AGS tended to increase, and the sludge volume index finally decreased to 50 mL/g. In addition, the size of the AGS gradually increased to about 1.0 mm. Therefore, the control of HRT provides favorable conditions for the stable formation of AGS, and is expected to improve the contaminant removal efficiency with the selection of a proper operation strategy.

폐광산 주변 토양 중금속 오염노출농도 우려기준과 위해성 비교 연구 (Comparison of Heavy Metal Pollutant Exposure and Risk Assessments in an Abandoned Mine Site)

  • 최진원;유근제;구명서;박준홍
    • 대한토목학회논문집
    • /
    • 제32권4B호
    • /
    • pp.261-266
    • /
    • 2012
  • 본 연구에서는 중금속에 의한 토양환경영향평가 시 노출농도 기반의 평가와 위해성 기반의 평가를 비교하였다. 이를 위해서 폐광산 지역에서 중금속 오염노출을 조사하였다. 발암위해도와 비발암위해도 평가 결과, 토양섭취의 영향이 토양접촉의 영향보다 지배적이었고, 우려기준을 초과하는 경우에는 총 위해도도 기준을 초과하였다. 우려기준을 초과하지 않는 경우도 대부분 총 위해도 기준을 초과하였으므로, 위해도 기반의 평가가 노출농도 기반의 평가보다 더 민감한 기준이라는 기존 인식을 확인하였다. 하지만 토양접촉 경로의 비발암위해성 결과들의 심층 분석 결과, 우려기준을 초과함에도 위해도 기준을 초과하지 않는 경우들이 검출되었다. 본 연구에서는 신뢰성 있는 폐광산지역의 토양오염정화사업 타당성 평가를 위해서는 현재 노출농도기반의 평가 위주에서 위해성 기반 평가로의 정책 전환의 필요성이 확인되었고, 위해도 원단위 및 판단기준의 객관적 설정을 위한 연구 필요성이 제시되었다.

국소평균공기연령을 이용한 국소환경시스템의 청정도 평가 및 예측 (Evaluation and Prediction of Cleanliness Level in the Mini-Environment System Using Local Mean Air-Age)

  • 노광철;이현철;박정일;오명도
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.457-466
    • /
    • 2007
  • A numerical and experimental study on the evaluation and the prediction of cleanliness level in the mini-environment system was carried out. Using the concept of local mean air-age (LMA) and effective flow rate, the new direct method for estimating the mini-environment was developed and compared with the previous performance index of airflow pattern characteristics. It was found out that the airflow pattern analysis is a restricted method to estimate the real performance of the mini-environment. The reason is that the airflow pattern cannot predict the effect of the increment of the ventilation rate on the cleanliness level in the mini-environment. While LMA is capable of showing the effects of the contaminant accumulation caused by turbulent intensity, eddy, and the increment of the effective flow rate. This result showed that LMA is more exact and effective performance index than the previous one like the airflow pattern characteristics.

지하수 수질측정망 자료를 활용한 시간적 오염도 추이변화 분석 (Temporal Trend Analysis of Contamination using Groundwater Quality Monitoring Network Data)

  • 방사라;유근제;박준홍
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.120-128
    • /
    • 2011
  • Korea Groundwater Quality Monitoring Network is a database of annual groundwater quality survey results to prevent groundwater pollution. We estimated contamination index (CI) values for each type of land use, and analyzed temporal trends of pollutant concentration data in the Groundwater Quality Monitoring Network from 2001 to 2009. Among the pollutants considered in the database, the concentrations of nitrate and chloride were higher than their standards. In the case of nitrate, recreation parks, golf courses and general waste dumping regions showed increasing trends according to linear regression analysis, whereas industrial complexes and residential regions of urgan and recreation parks showed increasing trends in the chloride concentration data. According to multiple variable linear regression analysis, EC, pH and topography were major factors influencing CI values. These results suggest that groundwater with a high CI value and increasing trend is vulnerable for potential contamination, which requires more careful groundwater pollution control.

H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구 (A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site)

  • 한정상
    • 자원환경지질
    • /
    • 제27권3호
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF