• 제목/요약/키워드: Contact work with high exposure

검색결과 17건 처리시간 0.022초

Neutron irradiation of alloy N and 316L stainless steel in contact with a molten chloride salt

  • Ezell, N. Dianne Bull;Raiman, Stephen S.;Kurley, J. Matt;McDuffee, Joel
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.920-926
    • /
    • 2021
  • Capsules containing NaCl-MgCl2 salt with 316L stainless steel or alloy N samples were irradiated in the Ohio State University Research Reactor for 21 nonconsecutive hours. A custom irradiation vessel was designed for this purpose, and details on its design and construction are given. Stainless steel samples that were irradiated during exposure had less corrosive attack than samples exposed to the same conditions without irradiation. Alloy N samples showed no significant effect of irradiation. This work shows a method for conducting in-reactor irradiation-corrosion experiments in static molten salts and presents preliminary data showing that neutron irradiation may decelerate corrosion of alloys in molten chloride salts.

The Type of Payment and Working Conditions

  • Rhee, Kyung Yong;Kim, Young Sun;Cho, Yoon Ho
    • Safety and Health at Work
    • /
    • 제6권4호
    • /
    • pp.289-294
    • /
    • 2015
  • Background: The type of payment is one of the important factors that has an effect on the health of employees, as a basic working condition. In the conventional research field of occupational safety and health, only the physical, chemical, biological, and ergonomic factors are treated as the main hazardous factors. Managerial factors and basic working conditions such as working hours and the type of payment are neglected. This paper aimed to investigate the association of the type of payment and the exposure to the various hazardous factors as an heuristic study. Methods: The third Korean Working Conditions Survey (KWCS) by the Occupational Safety and Health Research Institute in 2011 was used for this study. Among the total sample of 50,032 economically active persons, 34,788 employees were considered for analysis. This study examined the relation between the three types of payment such as basic fixed salary and wage, piece rate, and extra payment for bad and dangerous working conditions and exposure to hazardous factors like vibration, noise, temperature, chemical contact, and working at very high speeds. Multivariate regression analysis was used to measure the effect of the type of payment on working hours exposed to hazards. Results: The result showed that the proportion of employees with a basic fixed salary was 94.5%, the proportion with piece rates was 38.6%, and the proportion who received extra payment for hazardous working conditions was 11.7%. Conclusion: The piece rate was associated with exposure to working with tight deadlines and stressful jobs. This study had some limitations because KWCS was a cross-sectional survey.

테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구 (A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers)

  • 최호춘;홍좌령;이귀영;김두호;박정일
    • 한국산업보건학회지
    • /
    • 제21권3호
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

도장 부서 남성 근로자들의 피부 질환 (Skin diseases of male workers in painting workplace)

  • 박재범;이경종;장재연;정호근
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.830-839
    • /
    • 1997
  • 직업성 피부 질환을 일으키는 주요 작업 공정의 하나인 도장작업자들의 피부 질환의 실태를 파악하기 위하여 모 조선업체 도장 부서의 남자 근로자 379명을 폭로군으로, 같은 회사 비도장부서에서 근무하고 유기용제를 취급한 경력이 없는 근로자 151명을 대조군으로 선정하여 피부과 전문의의 진료와 설문 조사를 통하여 아래와 같은 결과를 얻었다. 피부과적 진찰 결과 도장부서 근로자들이 이환되어 있는 가장 흔한 피부질환은 족부 백선으로 폭로군의 유병률은 48.0%였으며 대조군에 비하여 이환될 비차비가 3.18로 통계학적으로 유의한 차이를 보였다. 접촉성 피부염과 한포진의 유병률도 각각 11.9%, 11.9%로 대조군보다 유의하게 높았으며 질병에 이환될 비차비가 4.95, 6.64로 통계학적으로 유의한 차이를 보였다. 이외에도 비특이적 습진, 자극성 피부염, 모낭염, 두드러기 등과 같은 피부 질환이 관찰되었으나 대조군과 유의한 차이는 없었다. 접촉 피부염 소견을 보이는 폭로군 중 71.1%가 피부 증상이 휴일이나 휴가시에 호전된다고 응답하였고, 68.9%가 옷이나 보호구에 가려지지 않는 노출부위에 피부 병변이 발생한다고 응답하여 접촉 피부염이 작업과 관계가 있음을 시사하였다. 근로자들의 보호구 착용률은 비교적 양호한 편이었지만 보호구 착용과 피부질환과는 연관성이 없어서 보호구 착용이 피부질환의 예방에 큰 효과가 없는 것으로 나타났다. 대조군과 유의한 차이를 보인 접촉 피부염, 한포진, 족부 백선의 유병률을 수행직무별로 스프레이군, 터치업군, 혼합군, 전처리군으로 구분하여 비교한 결과 유의한 차이를 보이지 않아 피부 질환의 위험도는 수행직무에 따라서는 큰 차이가 없음을 보여주었다. 도장 부서 근무 년수에 따른 비교에서도 근무 년수가 증가함에 따라 유병률이 증가하는 소견을 보이지 않았는데 근무 기간에 길어질수록 피부 저항이 증가되며, 피부반응이 둔해지며, 숙련된 작업으로 접촉물질에 대한 노출이 감소되기 때문이라고 판단된다. 이상과 같이 조선업체 도장부서 근로자들에게서 접촉 피부염, 한포진, 족부 백선 등 작업과 연관된 질병을 발견할 수 있었다. 앞으로 도장 부서 근로자들의 피부 병변을 예방하기 위한 대책 마련이 시급하다고 생각한다.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Skin Protection Seminars to Prevent Occupational Skin Diseases: Results of a Prospective Longitudinal Study in Apprentices of High-risk Professions

  • Wilke, Annika;Brans, Richard;Nordheider, Kathrin;Braumann, Antje;Hubner, Anja;Sonsmann, Flora K.;John, Swen M.;Wulfhorst, Britta
    • Safety and Health at Work
    • /
    • 제9권4호
    • /
    • pp.398-407
    • /
    • 2018
  • Background: Occupational skin diseases (OSDs) are frequent in professions with exposure to skin hazards. Thus, a health educational intervention for apprentices of high-risk professions was conducted. It was the aim of this study to gain insight into possible effects of this intervention. Methods: A one-time skin protection seminar was conducted in 140 apprentices of health-related and non-health-related professions [trained cohort (TC)]. In addition, 134 apprentices of the same occupations were monitored [untrained cohort (UTC)]. The OSD-specific knowledge and the skin condition of the hands were assessed at baseline (T0), after the seminar (T1), and after 6 (T2) and 12 months (T3). Results: The OSD-specific knowledge increased in all cohorts from T0 to T3, but we found a significantly higher knowledge in the TC at T2 (p < 0.001, t = 3.6, df = 196, 95% confidence interval = 0.9, 3.3) and T3 (p < 0.001, t = 3.8, df = 196, 95% confidence interval = 1.0, 3.2) compared to the UTC. Our results indicated a better skin condition of the hands in the TC of the health-related professions but not in the non-health-related professions. Conclusion: The study indicates that an educational intervention may positively influence the disease-specific knowledge and the prevalence of OSD in apprentices. However, definite conclusions cannot be drawn because of the heterogeneous study cohorts and the study design. Future research should aim at tailoring primary prevention to specific target groups, e.g., in view of the duration and frequency of skin protection education, different professions, and gender-specific prevention approaches.