The Observation of the Skin Contact Allergic Sensitization Test of Rhus-II with Guinea Pig Maximization Test (Guinea Pig Maximization Test에 의한 옻나무 추출액(Rhus-II)의 접촉 알러지성 자극에 관한 연구)

  • Choi Changsun;Han Dong Un
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • The purpose of the present study was to investigate differences in the sensitizing potential of Rhus Veniciflua(Rhus-II), when tested by the guinea pig maximization test(GPMT) and Freund's complete adjuvant test(FCAT) with an identical, intradermal induction concentration. A new grading classification of the sensitization potential is proposed. The GPMT was conducted according to OECD guideline $\#406$, using a multiple-dose design and test results were analysed with logistic regression analysis. During the induction stage, we injected intradermally each three site 0.1 ml(l mg/animal) test material, 0.1 ml complete Freund's adjuvant and 0.lml the test agent emulsified in the adjuvant. 7 days later, we induced weak sensitization with $10\%$ sodium lauryl sulfate(SLS) and applide 1ml(l0mg/animal) test agent topically on the same site and made a tight occlusion. 14 days later we challenged with 1 ml(l 0mg/animal) of test material on the flank and observed ant 24 hours and 48 hours later. The results were also observed $0\%$ at 24 hours challenge. The results observed 48 hours after challenge were the identical. These data indicated that, although Rhus-II is a no contact allergen. It was reported that the skin sensitization by Rhus-II was not detected the skin sensitization in the guinea pig maximization test (GPMT). Consequently, it was confirmed that Rhus-II had no contact allergic sensitization in guinea pig maximization test.

A Study on the Anisotropic Flow Characteristics of Droplets on Rice Leaf Surface (벼 잎 표면에서 액적의 이방성 흐름 특성에 관한 연구)

  • Kim, Tae Wan
    • Tribology and Lubricants
    • /
    • v.33 no.6
    • /
    • pp.251-255
    • /
    • 2017
  • In this study, we aimed to clarify the wettability and anisotropic flow characteristics of rice leaves as a basic study for engineering applications of anisotropic flow characteristics of rice leaf surface. To investigate the surface structure of rice leaf, the micro grooves and asperities of rice leaves were analyzed and quantified by scanning electron microscope, Confocal laser scanning microscopy, and stylus profilometer. The analysis of the structure of rice leaf surface confirmed that asymmetrical cone - like protrusions in leaf veins were inclined toward the leaf tip. The static contact angle test showed that the contact angle at the midline vein or leaf vein location where the micropapilla is concentrated is about $20^{\circ}$ higher than the leaf blade position. The contact angles of fresh and dried rice leave were also compared. The dried rice leaves showed a contact angle of about $5^{\circ}$ to $15^{\circ}$ higher than that of fresh leaves, suggesting that the volume of the protrusions decreased as the water was removed, thus reducing the contact area with the droplet. In the contact angle history test the hysteresis in the leaf tip direction was found to be much lower than that in the leaf petiole direction. This results can be explained that asymmetrical cone - like protrusions had a significant effect on the droplet flow characteristics through contact angle hysteresis experiment.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

A variably compliable probe system for the in-circuit test of a PCB (인쇄회로기판의 통전검사를 위한 가변순응력을 갖는 프로브 시스템)

  • Shim, Jae-Hong;Cho, Hyung-Suck;Kim, Sung-Kwun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.323-331
    • /
    • 1997
  • A new probing mechanism and an active compliance control algorithm have been developed for the in-circuit test of a PCB( printed circuit board ). Commercially available robotic probing devices are incapable of controlling contact force generated through rigid probe contacts with a solder joint, at high speed. The uncontrollable excessive contact force often brungs about some defects on the surface of the solder joint, which is plastically deformable over some limited contact force. This force also makes unstable contact motions resulting in unreliable test data. To overcome these problems, we propose that a serially connected macro and micro device with active compliance provide the best potential for a safe and reliable in-circuit test. This paper describes the design characteristics, modeling and control scheme of the newly proposed device. The experimental results clearly show the effectiveness of the proposed system.

  • PDF

Evaluation of the ohmic contact resistivity in Plasma display panels

  • Yang, Seung-Hee;Moon, Cheol-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.882-885
    • /
    • 2006
  • The contact resistivity of the black interlayer which has been introduced between BUS and ITO electrodes in a plasma display panel was evaluated using two kinds of specially designed test electrode patterns. Of the two, type 2 pattern was able to evaluate the contact resistivity more successfully, which was calculated as about $250{\Omega}$ in the suggested test pattern structure.

  • PDF

A Current Collection Performance On-line Test Plan in Korea High Speed Train Development Project (고속전철 기술개발사업 본선 시운전 집전시험계획)

  • 조용현;최강윤;백광선
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.156-162
    • /
    • 2001
  • Current collection performance on-line tests for a Korean High Speed Train being developed in G7 project is scheduled to start in June, 2002. In this paper, preparatory efforts for measuring contact forces which is regarded as one of major measuring items in the test are introduced. Specifically speaking, review of frequencies related with contact force fluctuations, brief of contact force measuring algorithm, review of measuring instrument specifications and development of a data acquisition program are presented.

  • PDF

Interrupting Test of Molded Case Circuit Breaker with Strong Driving Magnetic Force (강자계 구동형 460V/225A/50kA 배선용 차단기 대전력 차단성능평가)

  • Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.36-38
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widly used in power distribution systems. In the paper, it was investigated how much Interrupting capability was improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), Prior to the interrupting testing, it was necessary for the optimum design to analyze magnetic forces on the contact system, generated by current and flux density. This paper presents both our compuational analysis and test results contact system in MCCB.

  • PDF

The Status of Soft Contact Lens Wear in College Students in Korea (한국 대학생들의 소프트 콘택트렌즈 착용에 대한 실태)

  • Kim, Douk-Hoon;Kim, Joung-Suk;Mun, Joung-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.233-239
    • /
    • 2004
  • This study investigated the status of soft contact lens wear in college students. The results were as follows: 1. The most prevalent age of initial contact lens wear was 19 years or 20 years, with an age distribution in females from as early as 10 years to 20 years. 2. For almost all subjects, the test clinic for the contact lens wear assessment and purchase of the contact lenses was an optical shop. 3. The main advantage for most male subjects was use for sports, whereas most female subjects used contact lenses for cosmetic reasons. 4. The most common side-effects experienced due to contact lens wear were red eye, foreign body sensation, and eye pain. 5. The most frequently reported eye disease caused by contact lens wear was conjunctivitis, with only few subjects experiencing keratitis. 6. Following treatment for the side effects of contact lens wear, most subjects hoped to re-use the previous contact lenses, some subjects wanted to change to new contact lenses, and others subjects refused further contact lens wear.

  • PDF

Elastic properties of addition silicone interocclusal recording materials (부가중합형 실리콘 교합인기재의 탄성 특성)

  • Lee, Young-Ok;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

Seismic Rocking Response Analysis of 1/8 Scale Model for a Spent Fuel Storage Cask (사용후 연료 건식저장용기 1/8규모 축소모형 지진회전응답해석)

  • Lee J.H.;Seo K.S.;Koo G.H.;Cho C.H.;Choi B.I.;Lee H.Y.;Yeom S.H.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.383-389
    • /
    • 2005
  • This research is to develop a seismic response analysis method for a spent fuel storage cask. FEM model is built for the test model of 1/8 scale spent fuel dry storage cask using available 3D contact conditions in ABAQUS/Explicit. Input load for this analysis os a seismic wave of El-centro earthquake, and the friction and damping coefficients in the analysis condition we obtained from the test result. Penalty and kinematic contact methods of ABAQUS are used for mechanical contact formulation. The analysis method was verified for rocking angle obtained by seismic response tests. The kinematic contact method with an adequate normal contact stiffness showed a good agreement with tests.

  • PDF