• 제목/요약/키워드: Contact pressure

검색결과 1,705건 처리시간 0.027초

Behaviors of turn-to-turn contact resistance (Rc) of various REBCO CC tapes according to applied contact pressure

  • Jeong, Chanhun;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권3호
    • /
    • pp.15-20
    • /
    • 2018
  • No-insulation (NI) pancake magnets are fabricated using Rare earth-Barium-Copper Oxide (REBCO) coated conductor (CC) tapes, which enabled a very compact magnet in the aspects of high critical current density ($J_c$) and high mechanical strength by removing insulation and allowing thinner stabilizer. They have also advantages such as self-quench protection. Therefore, it does not need quench detection and protection that can be very challenging in a high critical temperature ($T_c$) superconducting magnet technology. Recently, it was reported that the NI REBCO CC magnets have some drawbacks of long charging time and high field ramp loss which will be a concern in the operation of cryocooled magnets. These issues are related to the turn-to-turn contact resistivity and can be released by managing it. This is also closely related to the activity of reducing the contact joint resistance in the case of CC joints for long length CC fabrication. Therefore, in this study, the turn-to-turn contact resistance ($R_c$) at the CC contact part of differently stabilized CC tapes was measured. The behaviors of $R_c$ at CC contact parts according to the applied contact pressure were investigated. The range of $R_c$ measured for CC tapes adopted will provide fundamental data for design and fabrication of the CC NI coils.

계장화한 긴 바를 사용한 세라믹판의 충격 파괴 거동 (Impact Fracture Behavior of Ceramic Plates Instrumented Long Bar)

  • 신형섭;배영준;오상엽;김창욱;장순남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.561-566
    • /
    • 2001
  • A long bar impact test to alumina plates(AD 85 and AD 90) was carried out by using fabricated impact testing apparatus. The apparatus adopting a long bar of 2.1m in length made it possible to measure directly the applied impact force to the specimen during bar impact. The dimension of specimens was $33{\times}33mm$ and thickness was 3.4mm. Confinement of D2=18mm outer diameter and D1=10.5mm inner diameter was used to provide contact pressure to the specimen. Contact pressure of p=100 or 200MPa was applied to specimen before impact test. Damage caused in those cases were compared with the case of without contact pressure. The damage of specimen was different depending upon the pressure level of confinement. The existence of confinement had suppressed the development of radial cracks from the bottom of specimen and reduced the extent of damage as compared with cases without contact pressure(p=0MPa). Because the application of contact pressure to the specimen increased the apparent flexural stiffness of specimen during bar impact, it had produced the change of developed damage in the specimen; from the radial cracks to the local contact stress dominant damage. It would contribute to the improvement of the ballistic property in ceramic plates.

  • PDF

A Study on the Distribution of Plantar Pressure in Adult Hemiplegia during Gait with the Use of Cane

  • Cha, Yong-Jun;Kim, Kyoung
    • The Journal of Korean Physical Therapy
    • /
    • 제22권3호
    • /
    • pp.49-53
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the plantar pressure distribution between the affected and unaffected side in adult hemiplegia during gait with the use of a quad-cane. Methods: Thirty-four stroke patients from 34 to 83 years of age were enrolled in this study, and in random order, all patients were asked to walk at their most comfortable speed three times along a walkway with the use of quad-cane over a period of three days. Plantar pressure distribution was measured with regard to foot contact pattern and center of pressure (CoP) trajectories during the stance phase, progressing from heel-strike to toe-off. The F-scan system was used to compare the foot pressure of the affected and unaffected sides. Results: A significant reduction in the total contact area, the width of fore foot (FF) and hind foot (HF), and anterior/posterior (AP) CoP trajectory of the affected side was found. However, contact pressure of the hind foot on the affected side during walking increased when compared to that on the unaffected side. Conclusion: We demonstrated that plantar pressure distribution on the affected side of adult hemiplegia patients was generally poorer than that on the unaffected side when these patients walked with cane assistance. However, the use of a quad-cane was shown to increase contact pressure of the hind foot on the affected side because weight can be borne on the affected side during heel-strike with use of the cane.

직교이방성 연료전지 스택의 유한요소 해석 (Finite Element Analysis of Fuel Cell Stack with Orthotropic Material Model)

  • 전지훈;황운봉;조규택;김수환;임태원
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.175-178
    • /
    • 2003
  • Mechanical behavior of a fuel stack was studied by the orthotropic material model. The fuel stack is mainly composed of bipolar plate (BP), gasket, end plate, membrane electrolyte assembly (MEA), and gas diffusion layer (GDL). Each component is fastened with a suitable pressure. It is very important to maintain a suitable contact pressure of BP, because it affects the efficiency of the fuel cell. This study compared mechanical behavior of various fastening types of the fuel cell stack. Bar, band, and modified band fastening type are used. The band fastening type showed that it reduces total volume of the cell, but it does not improve the contact pressure distribution of each BP. The modified band fastening type was designed by considering the deformations of band fastening type, and it showed a good enhancement of contact pressure distribution.

  • PDF

상호교환식 메트로놈 훈련이 만성 뇌졸중 환자의 족저압과 낙상효능감에 미치는 영향 (Effects of Interactive Metronome Training on the Plantar Pressure and Fall Efficacy in Chronic Stroke Patients)

  • 황원경;이한숙;박선욱
    • 대한물리의학회지
    • /
    • 제15권1호
    • /
    • pp.105-112
    • /
    • 2020
  • PURPOSE: This study examined the effects of Interactive Metronome training on the plantar pressure and fall efficacy in chronic stroke patients. METHODS: Twenty-two hemiplegic patients were allocated randomly to an experimental group and control group. The experimental group received conventional physical therapy and emphasized weight-bearing interactive metronome training, whereas the control group received conventional physical therapy. The training was performed three times per week, 40 minutes per each session, for a total of seven weeks. The plantar pressure was assessed using the contact area and contact pressure, whereas the fall efficacy was assessed using the FES (Fall Efficacy Scale), ABC (Activities-specific Balance Confidence scale) and FOFQ (Fear of Falling Questionnaire). RESULTS: After training, a significant increase was observed in the paretic side of the contact area and the paretic and non-paretic side of contact pressure in both groups (p<.05). The between-group differences in the changes before and after training were statistically significant in the paretic side of the contact pressure (p<.05). After training, both the FES of the between-group and ABC of the experimental group were increased significantly (p<.05), but the between-group differences in the changes before and after training were not statistically significant in the FES, ABC, and FOFQ (p>.05). CONCLUSION: Interactive Metronome training is considered an effective treatment for improving the contact pressure of the paretic side in chronic stroke patients.

Ergonomic Evaluation of Trunk-Forearm Support Type Chair

  • Lim, Seung Yeop;Won, Byeong Hee
    • 대한인간공학회지
    • /
    • 제33권2호
    • /
    • pp.143-153
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effects of trunk-forearm supported sitting on trunk flexion angle, trunk extensor fatigue and seat contact pressure. Background: The relationship between sitting posture and musculoskeletal disorders of the trunk extensor fatigue and seat contact pressure has been documented. The trunk-forearm support type ergonomic chair was devised from the fact that trunk-forearm support has been reported to reduce trunk extensor activity and discomfort. Method: Using three different sitting postures, upright ($P_1$), trunk-forearm supported ($P_2$) and normal sitting ($P_3$), six healthy subjects participated in the study. Motion capture system was used to collect head and trunk flexion angle, and surface electromyography (sEMG) was used to collect myoelectric signal of upper trapezius, lower trapezius, erector spinae, multifidus, and pressure mat system was used to measure seat contact pressure. Results: When trunk and forearm were supported by the ergonomic chair, higher head flexion angle showed upright > trunk-forearm supported > normal in order, and muscle fatigue showed less than upright and normal sitting. Mean seat contact pressure decreased 19% than upright sitting. But muscle fatigue was not affected by each condition. Conclusion: Trunk-forearm supported sitting of the ergonomic chair showed positive effect in respect of trunk and head flexion angle, trunk extensor fatigue, seat contact pressure. To acquire comprehensive understanding of the effectiveness of the ergonomic chair, further studies such as anatomical effects from measurement of external applied loading effect to the body from interface pressure analysis are required. Application: The results of the publishing trend analysis might help physiological effects of trunk-forearm support type chair.

선박 추진축 선미 베어링 압력 분포 해석 (Pressure Distribution Analysis for After Bush Bearing of Ship Propulsion Shaft)

  • 신상훈;최익흥
    • 대한조선학회논문집
    • /
    • 제41권3호
    • /
    • pp.35-40
    • /
    • 2004
  • Since the scale of vessels is growing up recently, some troubles between the shaft and after bush bearing are frequently reported. Generally, mean pressure on bush bearing is used as a design criterion. However, in some case of the long bearing such as after bush bearing of the propulsion shaft, it might be liable to be locally under high pressure. As for the main engine bearings and the intermediate shaft bearing, it is reasonable to take the mean pressure as a design criterion. But, in case of after bush bearing, it is not sufficient because of the possibility of high pressure caused by local contact. In this study, Hertzian contact condition was applied to evaluation of the local pressure for after bush bearing. To reduce the local maximum pressure, the height of the after bush bearing was controlled. It was found that local maximum pressure could be reduced effectively by taking a partial slope on the white metal of the aft bush bearing.

접촉결합부를 갖는 원통구조물의 열적,동적 특성 연구

  • 김선민;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.244-249
    • /
    • 1997
  • Internal and external heat sources will cause to deform to machine elements in the contact joint of structure,which results in the change of contact pressure distribution different from initial assembly. Heat induced variations of contact pressure will change the static and dynamic properties such as contact stiffness,damping as well as contact heat conduction in the structure. In order to design and control the intelligent machine tool operating in variant conditions more sophisticatedly, the good prediction for the changes of prescribed propeties are strongly required especially in the contact elements adjacent to the rotational or linear bearing This paper presents some computational and experimental results in regard to static and dynamic characteristics of the press-fitted bush and shaft assembly which is a model of the bearing innerrace and shaft assembly. In the condition of heat generation on the outer surface of the bush,the effects of changes in the negative clearance and the heat flux on pressure distribution and dynamic properties are investigated. Results of this study show that the edge effect of the bush and the initial clearance have effects on the transient dynamic characteristics significantiy.

복열테이퍼 롤러베어링 지지특성에 따른 오버헝 회전축 시스템의 동적 거동 예측 및 접촉부 압력 해석 (Prediction of the Dynamic behavior and Contact Pressure of Overhung Rotor Systems According to the Support Characteristics of Double-row Tapered Roller Bearings)

  • 김태우;서준호;김민수;유용훈
    • Tribology and Lubricants
    • /
    • 제39권4호
    • /
    • pp.154-166
    • /
    • 2023
  • This study establishes a numerical analysis model of the finite element overhung rotor supported by a DTRB and describes the stiffness properties of the DTRB. The vibration characteristics and contact pressure of the RBR system are predicted according to the DTRB support characteristics such as the initial axial compression and roller profile. The stiffness of the DTRB significantly varies depending on the initial axial compression and external load owing to the occurrence of rollers under the no-load condition and increase in the Hertz contact force. The increase in the initial axial compression increases the rigidity of the DTRB, thereby reducing the displacement of the RBR system and simultaneously increasing the natural frequency. However, above a certain initial axial compression, the effect becomes insignificant, and an excessive increase in the initial axial compression increases the contact pressure. The roller crowning radius, which gives a curvature in the longitudinal direction of the roller, decreases the displacement of the RBR system and increases the natural frequency as the value increases. However, an increase in the crowning radius increases the edge stress, causing a negative effect in terms of the contact pressure. These results show that the DTRB support characteristics required for reducing the vibration and contact pressure of the RBR system supported by the DTRB can be designed.

동력형 욕창예방제품의 교대부양 압력 프로파 특성 (Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.