• 제목/요약/키워드: Contact phenomenon

검색결과 374건 처리시간 0.033초

릴레이 접점 열화에 따른 바운싱 현상 분석 (Analysis of the Bouncing Phenomenon due to the Deterioration of the Relay Contact)

  • 류재만;최순호;박기훈;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제27권6호
    • /
    • pp.383-388
    • /
    • 2014
  • The relay used is gradually increased. Because it is possible to easily control the high voltage and current. Bounce phenomenon is generated in contact during operation relay. As the result, arc is generated at the contact, thereby shortening the contact lifetime. In this study, we analyzed the bouncing phenomenon due to deterioration. It can be seen from the experimental results, and it is minimized at about 100,000 times. Bouncing phenomenon to increase again after the minimization. Consequently, the bouncing related to contact weight and shape of contact surface.

고속전철 주행에 따른 이선현상 모의 시뮬레이터 개발 (Development of simulator by induced contact loss phenomenon for high-speed train operation)

  • 김재문;김양수;김철수;장진영;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.499-503
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

릴레이 접점의 부하에 따른 바운스 현상 분석 (Analysis of the Bounce Phenomenon According to the Load of the Relay Contact)

  • 최순호;김관식;류재만;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.115-119
    • /
    • 2015
  • The power relay can be easily controlled with high voltage and current through the contacts. For this reason, has become widely used range in a variety of applications. In this study, we measured the contact resistance between the bouncing phenomenon of contact due to the change of load. The results of the experiment, the contact resistance increases with the deterioration of the contact, it is possible to predict the life of the relay contacts through the contact resistance. And relay bounce duration time have occurred in 3.5 ms or less. In addition, it is possible to use the results to design an arc suppression circuit device.

수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감 (Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters)

  • 장진영;진강환;강정남;박동규;김윤호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.

전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구 (Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator)

  • 김재문;김양수
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

On the Contact of Partial Rotor Rub with Experimental Observations

  • Park, Yeon-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1630-1638
    • /
    • 2001
  • Partial rotor rub occurs when an obstacle on the stator of a rotating machinery disturbs the free whirling motion of the rotor, which is more common than full annular rub among the cases of rubbing in rotating machinery. The intermittent contacts and friction during partial rotor rub makes the phenomenon complex. The several nonlinear phenomena of superharmonics, subharmonics, and jump phenomenon are demonstrated for the partial rub using an experimental apparatus in this study. The orbit patterns are also measured experimentally. In order to explain the phenomena of partial rotor rub, the analytical model for the contact between the rotor and stator should be chosen carefully. In this respect, a piecewise-linear model and a rebound model using the coefficient of restitution are investigated on the basis of the experimental observations. Also, Numerical simulations for the two models of contact are done for the various system parameters of clearance, contact stiffness, and friction coefficient. The results show that the piecewise-linear model for partial rotor rub is more plausible to explain the experimental observgations.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험 (The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator)

  • 김재문;김양수;장진영;안정준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

전자접촉기 열화에 따른 전기적 특성 분석 (Analysis of Electrical Characteristics Due to Deterioration of Electromagnetic Contactor)

  • 최순호
    • 한국전기전자재료학회논문지
    • /
    • 제32권5호
    • /
    • pp.407-412
    • /
    • 2019
  • In this paper, the changes in the electrical characteristics (arc energy, contact resistance, and bouncing phenomenon) due to the deterioration of the contact are analyzed. The results are generally consistent and can be analyzed for contact deterioration. The results of the experiment demonstrate that the arc energy is linearly related to the current when the contact samples and the voltage conditions are the same. The contact resistance varies due to multiple factors, but is generally within a certain range, and the contact deterioration can be determined. Contact stabilization can be detected by the decrease in the bouncing phenomenon due to deterioration (the change of the shape of the contact).

전기차량 주행 중 이선상태에 따른 급전계통의 전압, 전류 동특성 연구 (A study on the dynamic characteristic of voltage and current in a feeder system in case of cause contact loss on driving an electrical railway vehicle)

  • 김재문;박영;김양수;이종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2215-2216
    • /
    • 2011
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to electrical railway vehicle is investigated from an electrical response point of view. To analysis voltage and current waveforms by induced contact loss phenomenon on driving electrical railway vehicle, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. Throughout prototype simulator and contact wire and catenary wire experiments, it is confirmed that current waveforms is distorted by contact loss phenomenon and in case of driving electrical railway vehicle.

  • PDF

릴레이 접점 특성에 미치는 전기적 접속의 영향 (Effect on the Relay Contact Characteristics According to the Presence of Electrical Connection)

  • 진인영;최순호;김관식;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.647-651
    • /
    • 2016
  • The power relay can easily control high voltage and high current through metallic contacts. In addition, it has the advantage in reasonable price. So it has been used in many applications. But the power relay has a weak point by mechanical movements. These mechanical movements cause the bouncing phenomenon. Arc and bouncing phenomenon are the main causes of electric abrasion and material erosion. In this study, mechanical repetitive experiments and repetitive experiments in electrically connected state are conducted. Then these two experimental results in terms of bouncing phenomenon and changes in the contact surface are compared. In all number of repetitions, contacts in an electrically connected state cause smaller number of bounce. Also, It has lower contents of silver on eroded surface than the other. The experimental results would be helpful to the further study of contacts life span.