• Title/Summary/Keyword: Contact parameter

Search Result 469, Processing Time 0.023 seconds

Nonlinear Vibration Analysis of Thin Perforated Plate with Wire Impact Damping (와이어 충돌감쇠를 갖는 다공성 박판의 비선형 진동 해석)

  • 김성대;김원진;이부윤;이종원
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.639-647
    • /
    • 2002
  • The nonlinear vibration of the thin perforated plate is analyzed in consideration of the V-shaped tension distribution and the effect of wire impact damping. The reduced order FEM model of the tension plate is obtained from dynamic condensation for the mass and stiffness matrices. Tension wire is modeled using the lumped parameter method to effectively describe its contact interactions with the plate. The nonlinear contact-impact model is composed of spring and damper elements, of which parameters are determined from the Hertzian contact theory and the restitution coefficient, respectively. From the evaluation of the computational accuracy and computation time for the deduced impact stiffness and damping coefficient, we determined proper values for the simulation works, accounting for the computational accuracy as well as the computational efficiency. Finally we discussed the results of nonlinear nitration analysis for variations of their design parameters.

Etching properties as the process parameter in high density plasma contact hole etching (고밀도 플라즈마를 이용한 contact hole 식각에서 공정 변수에 따른 식각 특성)

  • Kim, Gwan-Ha;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1376-1377
    • /
    • 2006
  • 본 연구에서는 고밀도 플라즈마 식각 시스템을 이용하여 contact hole 식각을 연구하였다. 실험은 공정 변수에 따른 식각 특성을 변화를 SEM 분석을 이용하여 보였으며 공정 압력 증가에 따른 contact hole 패턴의 하부 및 측면이 vertical 하지 못한 현상을 볼 수 있었으며 이는 과도한 라디컬 생성으로 인하여 식각 반응 부산물과 폴리머가 식각 패턴 밖으로 탈착되지 못하여 나타나는 것으로 생각되며 하부 bias 전력을 증가시킴으로써 식각 반응 부산물과 폴리머의 탈착을 도와 식각 프로파일 개선에 영향을 줌을 확인하였다. 또한, 본 장비의 낮은 전자온도 등의 특성으로 인하여 PR의 degradation 현상 등이 나타나지 않았다.

  • PDF

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.

Analysis of Signal Interference for 3-D Microsystems (3-D 마이크로시스템을 위한 신호 간섭 분석)

  • 정두연;이종호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.41-44
    • /
    • 2001
  • In this paper, we explain briefly polysilicon guard layer in a simple 3-D structure. Simulation was performed extensively to see interference and characterize the role of the polysilicon guard layer. Especially, we performed extensively S-parameter simulation to analysis the signal interference. The interference was characterized in terms of oxide thickness, polysilicon doping concentration, thickness, number of contact of polysilicon guard, and metal guard size.

  • PDF

PA study on selective emitter structure and Ni/Cu plating metallization for high efficiency crystalline silicon solar cells (결정질 실리콘 태양전지의 고효율 화를 위한 Selective emitter 구조 및 Ni/Cu plating 전극 구조 적용에 관한 연구)

  • Kim, Minjeong;Lee, Jaedoo;Lee, Soohong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.91.2-91.2
    • /
    • 2010
  • The use of plated front contact for metallization of silicon solar cell may alternative technologies as a screen printed and silver paste contact. This technologies should allow the formation of contact with low contact resistivity a high line conductivity and also reduction of shading losses. The better performance of Ni/Cu contacts is attributed to the reduced series resistance due to better contact conductivity of Ni with Si and subsequent electroplating of Cu on Ni. The ability to pattern narrower grid lines for reduced light shading combined with the lower resistance of a metal silicide contact and improved conductivity of plated deposit. This improves the FF as the series resistance is deduced. This is very much required in the case of low concentrator solar cells in which the series resistance is one of the important and dominant parameter that affect the cell performance. A selective emitter structure with highly dopes regions underneath the metal contacts, is widely known to be one of the most promising high-efficiency solution in solar cell processing. This paper using selective emitter structure technique, fabricated Ni/Cu plating metallization cell with a cell efficiency of 17.19%.

  • PDF

The Effect of Tension and Drop Height on Contact Angle of Droplet on Flexible Substrate in Roll-to-Roll Systems (롤투롤 시스템에서 플렉시블 소재에 인가된 장력과 분사 높이가 액적 접촉각에 미치는 영향)

  • Kim, Dongguk;Lee, Changwoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.3
    • /
    • pp.167-172
    • /
    • 2017
  • This study proposes a method for identifying correlations between tension and drop height for sessile droplets in a roll-to-roll processing system. The effect of tension and drop height on the contact angle of a sessile droplet is presented. Design of experiment (DOE) methodology and statistical analysis are used to define a correlation between the process parameters. The contact angle is decreased while increasing tension and drop height. The influence of the tension is less significant on the contact angle compared with the effect of the drop height. However, tension should be considered as a major parameter because it is not easy to fix with roll eccentricity and compensating speed of the driven roll. The results of this study show that the effect of tension on the contact angle of a sessile droplet is more important than drop height because the drop height is fixed when the process systems are determined.

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

Experimental Study on the Friction Characteristics of Pin-Bush Bearing Metals for Diesel Engine (디젤엔진용 핀부시 베어링 소재의 마찰특성에 관한 실험적 연구)

  • Kim, Chung-Kyun;Kim, Kyung-Seob
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.409-413
    • /
    • 2009
  • This paper presents the hardness and friction characteristics of pb-free pin-bush bearing metal, which is manufactured by a centrifugal casting technology. A bronze metal with a high hardness and low friction properties is usually used for Diesel engine pin-bush bearing and high pressure cylinder. Pb-free metal for pin-bush bearings shows a little high hardness of 120 Hv compared with that of a conventional Pb bearing metal of 100~110 Hv. In general, the friction coefficient of pin-bush bearings is affected by a rotating speed and a load for various rubbing contact modes. But a contact load is more influential parameter when the contact rubbing mode transits from a mixed lubrication to a dry friction contact. The experimental result shows that the friction coefficient is more unstable at the dry contact mode compared with that of other two rubbing modes such as oil film contact and mixed friction conditions.

A Study on Effect on Current Density Distribution, Inductance Gradient, and Contact Force by Variation of Armature and Rail Structure (아마츄어 및 레일의 구조 변화에 따른 전류 밀도, 인덕턴스 경도 및 접촉력의 영향 연구)

  • 김복기
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.59-64
    • /
    • 2001
  • The distribution of current in the conductors influenced by the armature geometry and velocity is an important parameter for determining performance of an electromagnetic launcher(EML). the electric current in the early launching stage tends to flow on the outer surfaces of the conductors, resulting in very high local electric current density. However, the tendency for current to concentrate on the surface is driven by the velocity skin effect later in launching stage. The high current density produces high local heating and, consequently, increases armature wear which causes several defects on EML system. This paper investigates the effects of rail/armature geometry on current density distribution, launcher inductance gradient (L'), and contact force. Three geometrical parameters are used here to characterize the railgun system. These are the ratio of contact length to root length, relative position of contact leading edge to root trailing edge, and the ratio of rail overhang to the rail height. The distribution of current density, L', contact force between various configurations of the armature and the rail are analyzed and compared by using the EMAP3D program.

  • PDF

The effect of surface contact angle on the behavior of frost formation in a fin-tube heat exchanger (핀-관 열교환기의 착상 거동에 대한 표면 접촉각의 영향)

  • Lee, K. S.;Jhee, S.;Lee, D. W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.95-101
    • /
    • 2000
  • The effect of surface contact angle on the behavior of frost formation in a fin-tube heat exchanger is investigated experimentally. It is shown that both heat exchangers with hydrophilic and hydrophobic surfaces appear to have a better thermal performance than bare aluminium heat exchanger, but the improvements are very small. There is a little increase in the amount of the frost deposited onto the heat exchanger with both hydrophilic and hydrophobic surface. However, the effect of contact angle on the frost density is observed ; the frost with high density forms on the heat exchanger with hydrophilic surface ; and the frost with low density is deposited onto the heat exchanger with hydrophobic surface when compared with the frost deposited onto the heat exchanger with bare aluminium surface. This may be attributed to the fact that the shape of water droplets which condense on the surface of heat exchanger at the early stage of frosting varies with contact angle, and thus makes a difference on the structure of frost formation. From the experiments with different relative humidity of inlet air, it is shown that the variations of operating parameter make no influence on the effect of surface contact angle on the frosting behavior in the heat exchanger.

  • PDF