• Title/Summary/Keyword: Contact condition

Search Result 1,537, Processing Time 0.033 seconds

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

Studies on the Stabilities of Insectcides Combined with some Stabilizers (살충제제(殺蟲製劑)의 안정성(安定性)에 관(關)한 연구(硏究))

  • Woo, Chong-Hak;Kim, Jae-Wan
    • Journal of Pharmaceutical Investigation
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 1971
  • The stability and toxicity test for p.p'-DDT, DDVP and dipterex that put to used sample in this study effects is follows A. about p.p'-DDT (1) In elevating the stability of p.p'-DDT, best stabilizing solvent was benzene. (2) The stability-agent has no difficulty as long as it not contain metal ion for instance $Z_n^{2+}$,$C_r^{3+}$,$Al^{3+}$,and $Fe^{2+or3+}$ but in case of contain $F_e^{3+}$, the combination of salicylaminoguanidine is best effective. (3) Using this product for water-suspension, We must use span 40 for stability agent and adding it at the same time. (4) We must use container which does not week alkali and metal ion but it is to preserved in tight light-resistant container. (5) The stopper of container is adapted with above-mentioned condition of container, but it is better not to use metal material. (6) This product needs opening ventilation more than 30 minutes after diffusion or spray and in the room we remove cause of remained poison by cleaning the bottom. B. about DDVP and Dipterex (1) Benzene or toluene in best solvent to preserve stability of DDVP and Dipterex. (2) Span 40 is superior for stability agent of this product and second is span 80. (3) The pH of solution is very stable in pH 5-6 and comparative stable in alkali more than p,p'-DDT. (4) Container is to preserved in tight, lightresistant container and especially be careful of outflow and inflow of water. (5) Because this product is centeral stimulant poison, we must pay attention to prevent cause of contact diadermic toxicity after use.

  • PDF

A Study on Orbital Forming Analysis of Automotive Hub Bearing using the Explicit Finite Element Method (외연적 유한요소법을 이용한 자동차 Hub Bearing의 Orbital Forming해석에 관한 연구)

  • Cho, Hyun-Jik;Koo, Jeong-Seo;Bae, Won-Rak;Lim, Jong-Soon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.29-36
    • /
    • 2008
  • In this paper, the orbital forming analysis of an automotive hub bearing was studied to predict forming performances using the explicit finite element method. To find an efficient solution technique for the orbital forming, axisymmetric finite element models and 3D solid element models were solved and numerically compared. The time scaling and mass scaling techniques were introduced to reduce the excessive computational time caused by small element size in case of the explicit finite element method. It was found from the numerical simulations on the orbital forming that the axisymmetric element models showed the similar results to the 3D solid element models in forming loads whereas the deformations at the inner race of bearing were quite different. Finally the strains at the inner race of bearing and the forming forces to the peen were measured for the same product of the numerical model by test, and were compared with the 3D solid element results. It was founded that the test results were in good agreements with the numerical ones.

Using frequency response function and wave propagation for locating damage in plates

  • Quek, Ser-Tong;Tua, Puat-Siong
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.343-365
    • /
    • 2008
  • In this study, the frequency domain method which utilizes the evaluation of changes in the structural mode shape is adopted to identify regions which contain localized damages. Frequency response function (FRF) values corresponding to the modal frequency, analogous to the mode shape coefficients, are used since change in natural frequency of the system is usually insignificant for localized damage. This method requires only few sensors to obtain the dynamic response of the structure at specific locations to determine the FRF via fast-Fourier transform (FFT). Numerical examples of an aluminum plate, which includes damages of varying severity, locations and combinations of multiple locations, are presented to demonstrate the feasibility of the method. An experimental verification of the method is also done using an aluminum plate with two different degrees of damage, namely a half-through notch and a through notch. The inconsistency in attaining the FRF values for practical applications due to varying impact load may be overcome via statistical averaging, although large variations in the loading in terms of the contact duration should still be avoided. Nonetheless, this method needs special attention when the damages induce notable changes in the modal frequency, such as when the damages are of high severity or cover more extensive area or near the boundary where the support condition is modified. This is largely due to the significant decrease in the frequency term compared to the increase in the vibration amplitude. For practical reasons such as the use of limited number of sensors and to facilitate automation, extending the resolution of this method of identification may not be efficient. Hence, methods based on wave propagation can be employed as a complement on the isolated region to provide an accurate localization as well as to trace the geometry of the damage.

A Study on the Changes and Influencing Factors fo Townscape in Korea since 1945 (解防後 韓國의 都市景觀 變遷 및 그 要因 硏究 - 서울을 중심으로 -)

  • 이경목
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.1-14
    • /
    • 1998
  • The purpose of this study is to find out how the urban landscape of Korea, especially Seoul, changed during the last half century since 1945. The modernization of Korea, which had begun in 1960's after the chaotic period caused by Korean War, influenced the rapid growth of cities and the radical changes of its structures. But the Western-minded planning theories based on rationalism and positivism was directly applied in developing our traditional cities and consequently the modern urban landscape including urban pattern, architectural style, and commercial and residential landscape revealed disharmony, discrepancy and inconsistency in skylines, streetscape and so on. The findings are summarized as follows. 1. Because the urban structure and pattern changed in undesirable manner in terms of land use and traffic circulation, cities as a whole resulted in exclusive and heterogeneous landscape, and citizens lost their identity and felt alienated. 2. Because the architectural forms of important and monumental buildings which influenced the character of streetscape were not so successful in inventing contemporary Korean Style in true sense, we still have difficulty in creating the urban landscape of originality and legibility. 3. Because from the beginning of this era almost all highrise buildings were designed by modernism-oriented western architects, the commercial landscape of central cities did not evoke a sense of place, and after the introduction of postmodernism this tendency is ore striking even in everyday ordinary streetscape. 4. The newly formed residential landscape which was mainly composed of highly dense and highrise apartment, not only evolved very overwhelming and ugly visual impact but also exposed many social problems in living condition, neighboring and face-to-face contact. In conclusion, in ordr to define the 'Koreanness' of our urban landscape, we have to struggle to combine traditional architectural heritage and native townscape with Western shape, thought and theory, no matter how difficult it may be.

  • PDF

The Effect of Acidification on Membrane Distillation Process for Strong Nitrogenous Wastewater (산화 전처리가 고강도 질소폐수의 막증류 공정에 미치는 영향)

  • Tun, Lat Lat;Jeong, Dawoon;Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.137-147
    • /
    • 2020
  • A direct contact membrane distillation (DCMD) was applied to treat strong nitrogenous wastewater of anaerobic digestion supernatant (ADS) and human urine (HU). The ammonia transfer was evaluated in terms of specific ammonia transfer (SAT) value, which is the ratio of total ammoniacal nitrogen divided by the amount of water transferred. The acidification resulted in low SAT values and high quality of produced water. The ammonia transfer control in the acidic condition was stronger for HU than ADS due to higher alkalinity (pH 8.8) and ammonia concentration (5700 mg-N/L) of HU. Acidified HU at pH 4 exhibited a SAT value of 1.64 × 10-5, which was significantly smaller than the SAT value of 3.00 × 10-3 for the original HU. The low pH enhanced the water flux for ADS, but HU showed a steep decrease in water flux due to enhanced fouling. It was considered that the fouling intensity in acidic conditions depends on the characteristics of the wastewater source. The major foulants on the MD membrane were NaCl, CaCO3 and CuSO4 as recognized by the SEM-EDS. Acidified ADS and HU at pH 4 showed relatively high N content of 8.18 % and 28.03 %, respectively, as organic fouling.

A case report of a long-term abandoned torn lingual nerve injury repaired by collagen nerve graft induced by lower third molar extraction

  • Fujita, Shigeyuki;Mizobata, Naoki;Nakanishi, Takashi;Tojyo, Itaru
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.60.1-60.6
    • /
    • 2019
  • Background: The lingual nerve plays an important role in multiple functions, including gustatory sensation and contact sensitivity and thermosensitivity. Misdiagnosed conservative treatments for serious lingual nerve (LN) injuries can induce the patient to serious mental disability. After continuous observation and critical diagnosis of the injury, in cases involving significant disruption of lingual nerve function, microneurosurgical reconstruction of the nerve is recommended. Direct anastomosis of the torn nerve ends without tension is the recommended approach. However, in cases that present significant gaps between the injured nerve ends, nerve grafts or conduits (tubes of various materials) are employed. Recently, various reconstruction materials for peripheral nerves were commercially offered especially in the USA, but the best method and material is still unclear in the world. There currently exists no conventional protocol for managing LN neurosensory deficiency in regard to optimal methods and the timing for surgical repair. In Japan, the allograft collagen nerve for peripheral nerves reconstruction was permitted in 2017, and we tried to use this allograft nerve and got a recommendable result. Case presentation: This report is a long-term abandoned torn LN reconstructed with allograft nerve induced by the lower third molar extraction. Conclusions: In early sick period, with the exact diagnosis, the LN disturbance should be managed. In a serious condition, the reconstruction with allograft nerve is one of the recommendable methods.

The use of spectroscopic Ellipsometey for the observation of diamond thin film growth by microwave plasma chemical vapor deposition (마이크로웨이브 플리즈마 화학기상증착에 의한 다이아몬드 박막의 성장 관찰을 위한 분광 Ellipsometry의 이용)

  • 홍병유
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.240-248
    • /
    • 1998
  • The plasma chemical vapor deposition is one of the most utilized techniques for the diamond growth. As the applications of diamond thin films prepared by plasma chemical vapor deposition(CVD) techniques become more demanding, improved fine-tuning and control of the process are required. The important parameters in diamond film deposition include the substrate temperature, $CH_4/H_2$ gas flow ratio, total, gas pressure, and gas excitation power. With the spectroscopic ellipsometry, the substrate temperature as well as the various parameters of the film can be determined without the physical contact and the destructiveness under the extreme environment associated with the diamond film deposition. It is introduced how the real-time spectroscopic ellipsometry is used and the data are analyzed with the view of getting the growth condition and the accompanied features for a good quality of diamond films. And it is determined the important parameters during the diamond film growth, which include the final sample will be measured with Raman spectroscopy to confirm the diamond component included in the film.

  • PDF

Rhodopsedomonas palustris P4를 이용한 Trickle Bed Reactor에서의 일산화탄소와 물로부터 연속적인 수소생산

  • Park, Ji-Yeong;Lee, Tae-Ho;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.241-244
    • /
    • 2000
  • Continuous $H_2$ production from CO and water was studied in a trickle bed reactor(TBR) using Rhodopspedomonas palustris P4. To achieve high cell density, R. palustris P4 were cultivated by a fed-batch culture mode under chemoheterotrophic and aerobic condition, and final cell concentration was 13 g/L. TBR could provide sufficient residence time for CO to contact with cell suspension circulating TBR. The maximum CO uptake rate was found to be 16 mmol/L/hr at gas retention time of 50 min and CO partial pressure of 0.4 atm. In our correlation of the experimental data with mathematical model of TBR, the TBR operation with P4 was found to be lie in an intermediate state between mass transfer limitation and kinetic limitation. Due to the high cell density as well as hydrogen production activity in this study, TBR operation showed a superior performance to other previous reports on microbial hydrogen production.

  • PDF

Stability Improvement of Esomeprazole Magnesium Dihydrate Enteric-Coated Tablet by Adding Alkalizing Agents (에스오메프라졸 마그네슘 이수화물을 함유하는 장용성 제제의 안정성 개선)

  • Cho, Young Ho;Jeon, Hyo Bin;Lee, Jong-Hwa;Lee, Gye Won
    • KSBB Journal
    • /
    • v.32 no.2
    • /
    • pp.108-116
    • /
    • 2017
  • Omeprazole, a benzimidazole derivative, suppresses gastric acid secretion by inhibiting $H^+/K^+$ ATPase in gastric parietals cells, and by reducing $H^+$ concentration. To improve stability of esomeprazole magnesium dihydrate (ESMD), enteric-coated preperation was composed of core tablet, subcoating and enteric coating layer. We were evaluated in vitro dissolution characteristics between test and reference ESMD preparation and stability. We could prepare enteric-coated formulation of ESMD by controlling disintegrating agent and coating ratio which could rapidly dissolved in neutral or alkali medium. The formulation D5 with crospovidone of 1.25% and coating ratio of 16.25% had a similar dissolution behavior compare to reference preparation. Difference factor ($f_1$) and similarity factor ($f_2$) were 0~15 and 50~100 and there was no significant difference in bioequivalence between formulations. The content and dissolution rate of formulation D5 were $96.54{\pm}0.21$ and $78.56{\pm}0.87%$ without change of color in accelerated condition ($40^{\circ}C$, RH 75%, high density polyethylene (HDPE) container) for 6 months. This study concluded that our enteric coated preparation of ESMD could be an useful method to improve stability of unstable drug without direct contact with coating material.