• 제목/요약/키워드: Contact Stability

검색결과 747건 처리시간 0.033초

개량된 비접촉형 RF 선량계 구현 (Development of an Improved RF Dosimeter)

  • 손종대;이승민;이흥호;이남호;김승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.540-543
    • /
    • 2003
  • This paper presents design and manufacture of RF type non-contact radiological dosage measuring device. It also concerns on the broad out-line and the ways of improvement about RF type non-contact radiation measuring device. Measuring radiological dosage with non-contact RF, the stability and efficiency of the measure have been improved by reforming constant current circuit. Furthermore, applying communication protocol in process makes it possible to achieve faster and more accurate communication than old circuit. On the base of those, RF type non-contact radiological dosage measuring device which consists of radiological dosage measuring module and Reader module has been designed and manufactured. While testing communication against embodied device, the possibility of the field application could be confirmed.

  • PDF

Implementation of an Autostereoscopic Virtual 3D Button in Non-contact Manner Using Simple Deep Learning Network

  • You, Sang-Hee;Hwang, Min;Kim, Ki-Hoon;Cho, Chang-Suk
    • Journal of Information Processing Systems
    • /
    • 제17권3호
    • /
    • pp.505-517
    • /
    • 2021
  • This research presented an implementation of autostereoscopic virtual three-dimensional (3D) button device as non-contact style. The proposed device has several characteristics about visible feature, non-contact use and artificial intelligence (AI) engine. The device was designed to be contactless to prevent virus contamination and consists of 3D buttons in a virtual stereoscopic view. To specify the button pressed virtually by fingertip pointing, a simple deep learning network having two stages without convolution filters was designed. As confirmed in the experiment, if the input data composition is clearly designed, the deep learning network does not need to be configured so complexly. As the results of testing and evaluation by the certification institute, the proposed button device shows high reliability and stability.

Stability of hydrophobic properties of plasma polymerized tetrakis(trimethylsilyloxy)silane film surface

  • Jang, Jinsub;Woo, Sungmin;Ban, Wonjin;Nam, Jaehyun;Lee, Yeji;Choi, Woo Seok;Jung, Donggeun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.147.1-147.1
    • /
    • 2016
  • Hydrophobic thin films are variously applicable for encapsulation of organic devices and water repulsive glass, etc. In this work, the stability of hydrophobic characteristics of plasma polymerized tetrakis (trimethylsilyloxy) silane (ppTTMSS) thin films were investigated. The films were deposited with plasma enhanced chemical vapor deposition (PECVD) on the glass. The deposition plasma power and deposition pressure was 70 W and 600 mTorr, respectively. Thereafter, deposited films were treated by 248nm KrF excimer laser. Stability of hydrophobic properties of plasma polymerized tetrakis(trimethylsilyloxy)silane film surface was tested by excimer laser irradiation, which is thought to simulate severe outdoor conditions. Excimer laser irradiation cycles changed from 10 to 200 cycles. The chemical structure and hydrophobicity of ppTTMSS films were analyzed by using Fourier transform infrared (FTIR) spectroscopy and water contact angle (WCA) measurement, respectively. Absorption spectra peaks and WCA of excimer laser treated ppTTMSS films did not change notably. These results show that our ppTTMSS films possess stable hydrophobic properties.

  • PDF

Biologic stability of plasma ion-implanted miniscrews

  • Cho, Young-Chae;Cha, Jung-Yul;Hwang, Chung-Ju;Park, Young-Chel;Jung, Han-Sung;Yu, Hyung-Seog
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.120-126
    • /
    • 2013
  • Objective: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications. Methods: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 mm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05). Results: No significant differences in any of the analyzed parameters were noted between the groups. Conclusions: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.

D-Limonene 유화공정에 의한 환경친화성 수성세정제 개발 (Development of Environmentally Friendly Aqueous Cleanser by Emulsification of D-Limonene)

  • 김민희;김시영;정갑섭;주창식
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.873-879
    • /
    • 2007
  • For the purpose of development of an environmentally friendly aqueous cleanser, some experimental researches on emulsification of D-limonene were performed. OA series surfactants with different molecular weight were adapted as an emulsifier for preparation of O/W emulsion. Cleaning power of aqueous cleanser was measured by a dipping method adapting abietic acid(AA) as a solubilizate. Besides, drop size and drop size distribution, contact angle and storage stability of the aqueous cleansers were also measured and relationships among them were examined. Decrease in molecular weight of surfactant induced small drop size and contact angie, resulting in high cleaning power of aqueous cleanser. Aqueous cleanser consisted of 3wt.% OA300 and 30wt.% D-limonene showed the highest cleaning power, but displayed unfortunately with low storage stability. The storage stability of the aqueous cleanser with OA300 was significantly enhanced by addition of 0.5wt.% OA600 at the expanse of decrease in cleaning power.

금속 구조 변화에 따른 선택 화학기상증착 W Plug의 접합 신뢰성 연구 (The Effects of Metal Structure on the Junction Stability of Sub-micron Contacts Using Selective CVD-W Plug)

  • 최경근;김춘환;박흥락;고철기
    • 전자공학회논문지A
    • /
    • 제31A권5호
    • /
    • pp.94-100
    • /
    • 1994
  • The junction failure mechanism of W plugs has not been fully understood while the selective W deposition has been widely used for plugging interconnection lines. In this paper, the thermal stability and junction failure mechanism of sub-micron contacts using selective CVD-W plugs were intensively studied with the metal lines of AISiCu, Ti/AISiCu and TiN/AISiCu. The experimental results showed that the contact chain resistance and leakage current in the AISiCu and Ti/AISiCu metallizations were significantly degraded after annealing. From the SEM analysis, it was found that the junction spiking, due to the Al atoms diffusion along the porous interface between selective CVD-W and contactside wall, caused the junction failure. In constast, there was no degradation of the contact resistance and junction leakage current in TiN/AISiCu metal structu-re. It is believed that the TiN barrier layer could prevent AI(Ti) atoms Fromdiffusing. Therefore, TiN barrier between W plug and Al should be used to impro-ve the thermal stability of sub-micron contacts using the selective CVD-W plugs.

  • PDF

Multibody simulation and descent control of a space lander

  • Pagani, A.;Azzara, R.;Augello, R.;Carrera, E.
    • Advances in aircraft and spacecraft science
    • /
    • 제7권2호
    • /
    • pp.91-113
    • /
    • 2020
  • This paper analyzes the terminal descent phase of a space lander on a surface of a celestial body. A multibody approach is adopted to build the physical model of the lander and the surface. In this work, a legged landing gear system is considered. Opportune modelling of the landing gear crashbox is implemented in order to accurately predict the kinetic energy. To ensure the stability of the lander while impacting the ground and to reduce the contact forces that arise in this maneuver, the multibody model makes use of a co-simulation with a dedicated control system. Two types of control systems are considered; one with only position variables and the other with position and velocity variables. The results demonstrate the good reliability of modern multibody technology to incorporate control algorithms to carry out stability analysis of ground impact of space landers. Moreover, from a comparison between the two control systems adopted, it is shown how the velocity control leads to lower contact forces and fuel consumption.

이종결합 고속회전 발사 탄의 비행 안정성에 결합력이 미치는 영향성 분석 (Analysis of How the Bonding Force between Two Assemblies Affects the Flight Stability of a High-speed Rotating Projectile)

  • 이상봉;최낙선;이종현;김상민;강병덕
    • 품질경영학회지
    • /
    • 제49권3호
    • /
    • pp.255-268
    • /
    • 2021
  • Purpose: We sought to understand why a high-speed rotating projectile featuring a fuze-and-body assembly sometimes exhibited airburst, and we intended to improve the flight stability by eliminating airburst. Methods: We performed characteristic factor analysis, structural mechanics modeling, and dynamic modeling and simulation; and we scheduled firing tests to discover the cause of airburst. We used a step-by-step procedure to analyze the reliability function for selecting the bonding force standard that prevents airburst. Results: The 00MM high-speed rotating projectile features a fuze bonded to a body assembly; the bonding sometimes can break on firing. The resulting contact force, vibration and roll damping during flight generated yaw. Flight became unstable; fuze operation triggered an airburst. Our reliability test improved the bonding force standard (the force was increased). When the bonding force was at least the minimum required, a firing test revealed that airburst/flight instability disappeared. Conclusion: Analysis and identification of the causes of flight instability and airburst render military training safer and enhance combat power. Ammunition must perform as designed. Our method can be used to set standards that improve the performances of similar types of ammunition.

Dynamic stability and structural improvement of vibrating electrically curved composite screen subjected to spherical impactor: Finite element and analytical methods

  • Xiao, Caiyuan;Zhang, Guiju
    • Steel and Composite Structures
    • /
    • 제43권5호
    • /
    • pp.533-552
    • /
    • 2022
  • The current article deals with the dynamic stability, and structural improvement of vibrating electrically curved screen on the viscoelastic substrate. By considering optimum value for radius curvature of the electrically curved screen, the structure improvement of the system occurs. For modeling the electrically system, the Maxwell's' equation is developed. Hertz contact model in employed to obtain contact forces between impactor and structure. Moreover, variational methods and nonlinear von Kármán model are used to derive boundary conditions (BCs) and nonlinear governing equations of the vibrating electrically curved screen. Galerkin and Multiple scales solution approach are coupled to solve the nonlinear set of governing equations of the vibrating electrically curved screen. Along with the analytical solution, 3D finite element simulation via ABAQUS package is provided with the aid of a FE package for simulating the current system's response. The results are categorized in 3 different sections. First, effects of geometrical and material parameters on the vibrational performance and stability of the curves panel. Second, physical properties of the impactor are taken in to account and their effect on the absorbed energy and velocity profile of the impactor are presented. Finally, effect of the radius and initial velocity on the mode shapes of the current structure is demonstrated.

Influence of different parameters on nonlinear friction-induced vibration characteristics of water lubricated stern bearings

  • Lin, Chang-Gang;Zou, Ming-Song;Zhang, Hai-Cheng;Qi, Li-Bo;Liu, Shu-Xiao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.746-757
    • /
    • 2021
  • To investigate the mechanism of friction-induced vibration and noise of ship water lubricated stern bearings, a two-degree-of-freedom (2-DOF) nonlinear self-excited vibration model is established. The novelty of this work lies in the detailed analysis of influence of different parameters on the stability and nonlinear vibration characteristics of the system, which provides a theoretical basis for the various friction vibration and noise phenomenon and has a very important directive meaning for low noise design of water lubricated stern bearings. The results reveal that the change of any parameter, such as rotating speed of shaft, contact pressure, friction coefficient, system damping and stiffness, has an important influence on the stability and nonlinear response of the system. The vibration amplitudes of the system increase as (a) rotating speed of shaft, contact pressure, and the ratio of static friction coefficient to dynamic friction coefficient increase and (b) the transmission damping between motor and shaft decreases. The frequency spectrum of the system is modulated by the first mode natural frequency, which is continuous multi-harmonics of the first mode natural frequency. The response of the system presents a quasi-periodic motion.