• Title/Summary/Keyword: Contact Pressure Sensor

Search Result 94, Processing Time 0.063 seconds

Evaluation of Heat Loss by Means of Plasma Jet Ignition during Combustion Duration in the Constant Volume Vessel (정적연소실내에서의 플라즈마 제트 점화에 대한 연소기간중의 열손실산정)

  • 김문헌;문경태;박정서;김홍성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.96-103
    • /
    • 2003
  • In this paper, the heat loss to the constant volume vessel wall was investigated using instantaneous heat flux sensor, schlieren visualization, pressure rise curve. And the heat loss characteristics of plasma jet ignition were compared with conventional spark ignition. In case of plasma jet ignition, the flame kernel moves toward the center of combustion vessel in the initial period of combustion, and the flame surface spread out to the vessel wall. However, in case of conventional spark ignition, the flame surface contact with combustion vessel wall in the initial period of combustion. As a result, heat loss in the combustion duration for conventional spark ignition increase faster than that of plasma jet ignition. And the combustion enhancement rate of plasma jet ignition is higher than that of conventional spark ignition, and it was found that the heat loss rate is inversely proportional to the combustion enhancement rate.

Pressure Sensitive Device Using Conductive and Porous Structures (전도성 다공성 구조 압력감지소자)

  • So, Hye-Mi;Park, Cheolmin;Chang, Won Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.601-605
    • /
    • 2014
  • Porous conductors are known to demonstrate excellent electrical, mechanical, and chemical resistance. These porous conductors demonstrated potential applications in various fields such as electrodes for supercapacitors, flexible heaters, catalytic electrodes, and sorbents. In this study, we described a pressure sensitive device using conductive and porous sponges. With an extremely simple "dipping and drying" process using a single-walled carbon nanotube (SWCNT) solution, we produced conductive sponges with sheet resistance of < $30k{\Omega}/sq$. These carbon nanotube sponges can be deformed into any shape elastically and repeatedly compressed to large strains without collapse. The pressure sensors developed from these sponges demonstrated high resistance change under pressure of up to a half of their initial resistance.

Research of Body Pressure Distribution Change with the Use of BackJoy and Satisfaction of Human Sensibility

  • Kim, Kwangoh;Yoon, Jungmin;Ahn, Sungyong;Kim, Daseuran;Park, Peom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effect of BackJoy on how it effectively reduces the physical load generated in a posture in which the user sits, increases user's comfort and satisfaction, and maintains the correct posture. Background: Because of development of science and economic development, most office workers and students spend about 75% of their working time in chairs. However most of them have a poor posture. Method: This experiment conducted measurement using a pressure mat and surveyed to evaluate fatigue level, satisfaction and comfort of sit. The study is experimented 20 male and 14 female participants. The participants carried out four different types of tasks and each task took 20 minutes long. Results: In the case of experiment results before and after the use of BackJoy, average pressure, contact area and pressure per unit area appear to prove that using BackJoy is more effective. Conclusion: Through this study, the BackJoy's effects for the maintenance of good posture and loads that occur in the body are reduced. In the future study, there are some researches needed for various verifications using an EMG sensor that shows loads of vertebrae and we need to analyze each group of the participants by dividing them. Application: The evaluation method used in this study can be applied to evaluating ergonomic chairs.

Device Design for Inspection Curved Pipes using the Mobile Robot (이동로봇을 이용한 곡관(Curved Pipes) 검사용 디바이스 설계)

  • 조현영;최창환;최용제;김승호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1458-1462
    • /
    • 2003
  • High temperature and high pressure heavy water flows through the pipes in atomic power plants. The curved parts of pipes are critical parts in that they change the direction of steam flow, and these parts are especially affected by severe wear. Therefore, most pipes in atomic power plants are tested by non-destructive examination by workers who use ultrasonic sensors to measure the wall thickness of pipes. But not only are these pipes located in a very dangerous environment, but the space is also very limited. For the safety of workers, it is necessary to design a device that uses a mobile robot that can inspect curved pipes. This paper presents the design and construction of a small device that can generate the necessary contact forces between ultrasonic sensors and pipe walls in a limited space. And a mobile robot is used in place ortho worker for successful non-destructive examination.

  • PDF

A Study on the Hydrostatic Test of Slipper Pad for Hydraulic Piston Motor (유압 피스톤모터용 Slipper Pad의 정압시험에 관한 연구)

  • 함영복;김광영;김형의
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.645-649
    • /
    • 1997
  • In case of swash plate type axial piston hydraulic motor, hydrostatic bearing used to achieve the lubrication effect on the mechanical sliding contact areas between the following parirs ; sliooer-pad and swash plate,piston and cylinder bore,valve plate and cylinder block, etc. This study discussed the basic charateristic for the hydrostatic slipper-pad bearings with the capillary or orifice restrictor under static load condition. And, we also development of hydrostatic bearing tester for hydrostatic balancing test of pistion & slipper-pad assembly, and some experimental data on supply pressure step responce are reported.

  • PDF

Noble Development of Array Type Gripper for Robot Arm

  • Lee, Jaeman;Lee, Wangheon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_1
    • /
    • pp.185-193
    • /
    • 2022
  • For grippers of industrial robots, parallel grippers and multi-function finger grippers are used. The former has the advantage of low cost but has the disadvantage of low precision, and the latter has the advantage of excellent precision but has the disadvantage of being expensive. In this paper, we developed a grip that can detects the various shapes of the object to be gripped on the gripper surface by using mesured pressure information frome Veloset Sheet sensor so that the gripper can be gripped without deforming the surface of the gripper. Also we did not only developed the array type gripper and 4 array type grippers (ATG), but also confirmed the usefulness of array type gripper developed in this study according to the 4 predefined evaluation criteria

Nondestructive Buckling Load Prediction of Pressurized Unstiffened Metallic Cylinder Using Vibration Correlation Technique (Vibration Correlation Technique을 이용한 내부 압력을 받는 금속재 단순 원통 구조의 비파괴적 전역 좌굴 하중 예측)

  • Jeon, Min-Hyeok;Kong, Seung-Taek;Cho, Hyun-Jun;Kim, In-Gul;Park, Jae-Sang;Yoo, Joon-Tae;Yoon, Yeoung-Ha
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.2
    • /
    • pp.75-82
    • /
    • 2022
  • Nondestructive method to predict buckling load for the propellant tank of launch vehicle should be evaluated. Vibration correlation technique can predict the global buckling load of unstiffened cylindrical structure with geometric initial imperfection using correlation of natural frequency and compressive load from compressive test below the buckling load. In this study, vibration and buckling tests of a thin metal unstiffened propellant tank model subjected to internal pressure and compressive loads were performed and the test results were used for VCT to predict global buckling load. For the vibration test of thin structure, non-contact excitation method using a speaker was used. The response was measured with piezoelectric polymer(PVDF) sensor. Prediction results of VCT were compared with the measured buckling load in the test and the nondestructive global buckling load prediction method was verified.

The Finite Element Analysis for a Micro Turbine Fabricated by LIGA-like Process (LIGA-like 공정으로 제작된 마이크로 터빈의 유한 요소 해석)

  • Oh, J.;Choi, B.;Kim, N.
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.380-388
    • /
    • 2000
  • The finite element analysis of a micro turbine was made to investigate safety margin of its operating condition for the high aspect ratio nickel micro turbine blades fabricated by conventional LIGA-like method. From our study, we found that the fabricated turbine could not exceed its yield strength even if the pressure difference between inlet and outlet of turbine blade was about 44kPa, and the correlation of friction coefficient and the maximum stress, caused by contact friction between outer diameter of shaft and inner diameter of turbine blade, was somewhat reciprocal. The maximum stress was decreased with the increasing contact friction, when turbine blade was in its state of rotation. By the results of our study, we conclude that it is possible to fabricate metal micro turbine more easily han surface micromachining technology and to operate with no risk of metal structure's damage, which is caused by yield strength, if the operating condition with the design of micro turbine itself are optimized. It is useful to adopt other applications which have the contact problems between a moving part and the fixed one in micro structures.

  • PDF

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

A Study on Sleep Quality Algorithm by Piezo Sensor Signal (Piezo Sensor Signal에 의한 수면의 질 Algorithm에 관한 연구)

  • Byun, Jae-Ryoung;Cho, We-Duck;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.324-326
    • /
    • 2011
  • Measuring a biosignal during sleep is an important part of diagnosis and treatment of sleep disorder and also used to determine the general quality of sleep. As in current polysomnography, Contact method, which requires the attachment of electrodes to the skin, is the typical method to measure a biosignal during sleep. The procedure of this test is often considered to be inconvenient and tiresome because it requires attaching the device to the skin for each observation, and also limits free movement throughout the test. For this reason, the research on the acquiring the biosignal information without any attachment of a fixture on the skin is being conducted actively these days. In this study, it is suggested to check the heart rate per minute and the presence of breathing by placing a Piezo, which is a film type of pressure sensor, on the bed.

  • PDF