• Title/Summary/Keyword: Contact Joint

Search Result 548, Processing Time 0.027 seconds

Modeling of 2D Joints Using Contact (접촉을 이용한 2차원 조인트들의 모델링에 관한 연구)

  • Han, Hyung Suk;Park, Tae Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.92-101
    • /
    • 1997
  • In this paper, modeling methods for 2D joints are proposed. Earlier methods for modeling 2D joints that use geometric relationships may not consider irregularities or dynamic effects of joints. In any case, it is important to consider irregularities or dynamic effects. To consider those, methods that use dynamic contacts are proposed. With the method, 2D joints that have irregularities or dynamic effects amy be model- ed and analyzed. 2D joints that are developed are revolute, translational, gear and point-follower joint.

  • PDF

Grasping Impact-Improvement of Robot Hands using Proximate Sensor (근접 센서를 이용한 로봇 손의 파지 충격 개선)

  • Hong, Yeh-Sun;Chin, Seong-Mu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.42-48
    • /
    • 1999
  • A control method for a robot hand grasping a object in a partially unknown environment will be proposed, where a proximate sensor detecting the distance between the fingertip and object was used. Particularly, the finger joints were driven servo-pneumatically in this study. Based on the proximate sensor signal the finger motion controller could plan the grasping process divided in three phases ; fast aproach, slow transitional contact and contact force control. That is, the fingertip approached to the object with full speed, until the output signal of the proximate sensor began to change. Within the perating range of the proximate sensor, the finger joint was moved by a state-variable feedback position controller in order to obtain a smooth contact with the object. The contact force of fingertip was then controlled using the blocked-line pressure sensitivity of the flow control servovalve for finger joint control. In this way, the grasping impact could be reduced without reducing the object approaching speed. The performance of the proposed grasping method was experimentally compared with that of a open loop-controlled one.

  • PDF

FEM Analysis of the Spline Joint with Bolt Pre-load (스플라인결합 조인트의 볼트 예하중에 대한 유한요소 해석)

  • Tak, Seung-Min;Kang, Min-Kyu;Park, Dong-Jin;Lee, Seok-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.11
    • /
    • pp.1316-1322
    • /
    • 2011
  • Most of the mechanical structures use bolting or spot welding for the whole structure. In recent years, bolting & rivets are used rather than the welding due to reassembly and repair. Analysis of bolted joints is so complicate that many conditions must be considered such as pre-load and contact, etc.. Bolted joint analysis is done by theoretical, experimental & numerical methods. However, numerical analysis in the bolted joint is used because the contact and stress in the joints are changed due to the pre-load. In this study, we analysis the slip and the deformation of the contact area in the joint depending on the pre-load and find the optimized bolting condition.

Toe-in Gait, Associated Complications, and Available Conservative Treatments: A Systematic Review of Literature

  • Mohammad Taghi Karimi
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • Purpose: Toe-in gait is defined as a style of walking in which the foot turns inward. It may be caused by an increase in femoral bone anteversion, tibia torsion, and metatarsus adductus. There are some conservative treatment approaches used to correct this condition. This review aimed to determine the effects of the toe-in gait on joint loading, kinematics, and kinetic parameters while walking. Moreover, it sought to determine the efficiency of various conservative treatments used to correct the condition. Materials and Methods: A literature search was conducted in the following databases: PubMed, Institute for Scientific Information (ISI), Web of Science database, EBSCO, and Embase, using the following keywords in toe, toe-in, toeing, in-toe, pigeon toe, and conservative treatment published between 1950 and 2021. The quality of the studies was evaluated using the Down and Black tool. Results: A total of 13 papers on the impact of toe-in gait on joint contact force, kinematics, kinetic parameters, and conservative approaches to management were found. The quality of the studies varied between a score of 11 and 22. The toe-in gait influences the joint contact forces and kinematics of the joints, especially the hip and pelvis. The effects of conservative treatment on the toe-in gait appear to be controversial. Conclusion: As the toe-in gait influences the joint contact force, it may increase the incidence of degenerative joint diseases. Therefore, treatment is recommended. However, there is no strong evidence on the efficacy of conservative treatments, and there are no recommendations for the use of these treatments in subjects with toe-in gait.

Biomechanical Analysis of Lower Extremity Joints According to Landing Types during Maximum Vertical Jump after Jump Landing in Youth Sports Athletes (유소년 스포츠 선수들의 점프착지 후 수직점프 동작 시 착지 유형에 따른 하지관절의 운동역학적 분석)

  • Jiho Park;Joo Nyeon Kim;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.3
    • /
    • pp.110-117
    • /
    • 2023
  • Objective: The purpose of this study was to find out kinematic and kinetic differences the lower extremity joint according to the landing type during vertical jump movement after jump landing, and to present an efficient landing method to reduce the incidence of injury in youth players. Method: Total of 24 Youth players under Korean Sport and Olympic Committee, who used either heel contact landing (HCG) or toe contact landing (TCG) participated in this study (HCG (12): CG height: 168.7 ± 9.7 cm, weight: 60.9 ± 11.6 kg, age: 14.1 ± 0.9 yrs., career: 4.3 ± 2.9 yrs., TCG height: 174.8 ± 4.9 cm, weight: 66.9 ± 9.9 kg, age 13.9 ± 0.8 yrs., career: 4.7 ± 2.0 yrs.). Participants were asked to perform jump landing consecutively followed by vertical jump. A 3-dimensional motion analysis with 19 infrared cameras and 2 force plates was performed in this study. To find out the significance between two landing styles independent t-test was performed and significance level was set at .05. Results: HCG showed a significantly higher dorsi flexion, extension and flexion angle at ankle, knee and hip joints, respectively compared with those of TCG (p<.05). Also, HCG revealed reduced RoM at ankle joint while it showed increased RoM at knee joint compared to TCG (p<.05). In addition, HGC showed greater peak force, a loading rate, and impulse than those of TCG (p<.05). Finally, greater planta flexion moment was revealed in TCG compared to HCG at ankle joint. For the knee joint HCG showed extension and flexion moment in E1 and E2, respectively, while TCG showed opposite results. Conclusion: Compared to toe contact landing, the heel contact landing is not expected to have an advantage in terms of absorbing and dispersing the impact of contact with the ground to the joint. If these movements continuously used, performance may deteriorate, including injuries, so it is believed that education on safe landing methods is needed for young athletes whose musculoskeletal growth is not fully mature.

An Analysis of Fretting by the Frictional Contact (摩擦 接觸으로 인한 Fretting에 대한 연구)

  • 이대희;최동훈;윤갑영;임장근
    • Tribology and Lubricants
    • /
    • v.6 no.1
    • /
    • pp.99-107
    • /
    • 1990
  • Most of machines and structures contain the elements which contact each other directly. When these elements subjected to vibration or repeated load, local relative movement occurs between the elements in contact which results in, a kind of wear. In order to know the factors which govern fretting, we have to analyze the phenomenon of microslip which causes fretting by using a general and efficient method from a viewpoint of contact mechanics. Based on the results of analysis, it is necessary to propose the way of minizing fretting which is one of the most significant surface failure. In this report, a general and efficient algorithm is applied to analyze the contact problem of the bolted joint, which is one of the typical elements damaged by fretting, with ratios of plate thickness, the ratios of Young's moduli, the ratios of the plate thickness to bolt radius varied. Finally, the ways of minizing fretting for the boked joint are suggested.

A Study on the Contact Stress Analysis of the Artificial Hip Joint Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • 김청균;윤종덕
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.189-194
    • /
    • 1996
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires the re-replacement of the hip joint beacuse it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focused on the development of the new materials. The research of new material, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find the new combination of the materials in the total hip replacement which has the excellent contact characteristics. The finite element uses MARC and the 5-node aximetric element. The results show that in case of acetabulum UHMWP has good characteristics, in femoral head, the $Al_2O_3$, and in stem, Ti6Al4V.

  • PDF

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

Study on the Design Methodology of Constant Velocity Joints for Passenger Cars using DOE (실험계획법을 활용한 승용차용 등속조인트 설계기법 연구)

  • Jeong, Chang-Hyun;Jung, Do-Hyun;Bae, Won-Rak
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.121-133
    • /
    • 2008
  • We presented design methodology of constant velocity joint for passenger cars using design of experiment. On the basis of contact normal stress of internal components of constant velocity joints, we performed a sensitivity analysis of several design parameters. And then we performed robust design and optimization design process. As a result, we could find robust design and also propose the optimized design. Presented design process would be very helpful for engineers who are suffer for new constant velocity joint design.

Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • Kim, Chung-Kyun;Yoon, Jong-Deok
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.