• 제목/요약/키워드: Contact Distance

검색결과 614건 처리시간 0.025초

반복 미끄럼 접촉에 의한 표면층의 경화에 대한 연구 (A Study on the surface hardening by repeated sliding contact)

  • 박준목;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제25회 춘계학술대회
    • /
    • pp.80-88
    • /
    • 1997
  • Repeated sliding contact wear test was performed with copper specimens to obtain the relationship between wear and surface hardening. Wear surface and wear track section were observed by optical microscopy. Wear volume and micro-vikers hardness of sublayer below wear surface were obtained. These results suggested that wear mechanism depended on contact load than sliding velocity. Therefore wear mechanism was abrasive wear within critical contact load and adhesive wear over critical contact load. Wear rate increased with contact load, sliding distance but decreased with sliding velocity. Surface hardening increased with sliding velocity and sliding distance but decreased with contact load.

  • PDF

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • 제47권3호
    • /
    • pp.182-192
    • /
    • 2017
  • Purpose: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.

Pulsed Nd:YAG 레이저 조사거리에 따른 상아질의 온도변화 (Temperature Changes in Dentin upon Pulsed Nd:YAG Lasing Distance)

  • Jae-Hyung Kim;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.327-334
    • /
    • 1995
  • In order to observe the influence of pulsed Nd:YAG laser at its out-of-contact with dentin on tooth temperature, we have applied pulsed Nd:YAG laser to 2mm thick dentin sample at a point of contact and from a distance of 1mm, 2mm, 3mm and 4mm with an energy of 0.3W, 0.5W, 0.8W, 1.5W and 2.0W. They were exposed to periods of 3 seconds, 6 seconds, 9 seconds and 15 seconds respectively and measured temperature changes. The results as follows : 1. When the time ad intensity of power were constant, the temperature changes on dentin of tooth depended on the distance. The temperature increased when the laser intensity increased bu two other conditions were contact. 2. At the point of contact, the temperature has risen over $5^{\circ}C$ regrdless of intensity of the power or the time. However, there was $5^{\circ}C$ fluctuation with 0.3 W for 3 seconds treatment. 3. The temperature change was less than $5^{\circ}C$ thermal change at the distance of 1mm and 2mm respectively when lased for 3 seconds, 6 seconds, 12 seconds and 15 seconds with 0.3 W. Similar results were observed at 3 and 6 seconds treatment with 0.5 W and at 3 seconds treatment with 0.8 and 1.0W respectively. 4. It showed less than 5(C thermal change when lased for 3 seconds, 6 seconds, 9 seconds, 12 seconds and 15 seconds with 0.3W at the distance of 3mm and 4mm. The same results were seen in 3 seconds, 6 seconds and 9 seconds treatment with 0.5W and in 3 seconds with 0.8W and 1.0W respectively. As we have seen the above, the results has indicated that pulsed Nd:YAG lasing at its off contact on dentin of 2mm thickness will not cause irreversible changes if lasing intensity, lasing distance and lasing time are appropriate.

  • PDF

가열된 표면에 고착된 한 쌍의 액적 증발 특성 (Evaporation Characteristics of Paired Sessile Droplets on a Heated Substrate)

  • 이형주;황원영;김정호;최창경;이성혁
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.113-118
    • /
    • 2023
  • This study investigates the evaporation characteristics of paired sessile droplets on a heated substrate. In particular, the evaporation time and contact line behaviors were analyzed based on the droplet-to-droplet distance and substrate temperature. The contact line behavior and volume variations were visualized using the shadowgraph method. It was observed that the contact diameter and contact angle exhibited similar behavior for both single and paired droplets regardless of the droplet-to-droplet distance and substrate temperature. The paired droplets demonstrated a longer evaporation time than the single droplet due to the vapor accumulation between the droplets. Furthermore, the scaled lifetime, defined as the ratio of evaporation time between paired and single droplets, increased as the droplet-to-droplet distance decreased and decreased as the substrate temperature increased, attributed natural convection.

리더와의 접촉빈도와 심리적 거리가 직무 디스트레스에 미치는 영향: 구성원이 인지하는 셀프리더십의 매개효과 (Contact Frequency and Psychological Distance between Leaders: Job Distress and Mediation through Employees' Perceived Self-Leadership)

  • 양회창;전준호;박종록
    • 유통과학연구
    • /
    • 제12권6호
    • /
    • pp.41-48
    • /
    • 2014
  • Purpose - This study aims to investigate a solution to reduce the negative reactions arising from the performance of duties or the job distress of workers in the service industry, because human resource statistics regarding workers in the service sector have been unreported, while concerns regarding exposure to emotional exertion and poor working conditions have been continuously increasing. Research design, data, and methodology - This study specifically focused on workers in highway service areas. It differs from previous studies because it involves the perspective of the person-organization fit and regards workers' cognition of leaders through the psychological distance toward the leader and the contact frequency between workers and leaders within the framework of the leader-individual fit. Moreover, this study highlights the role of the self-leadership of workers as an important factor that becomes manifested in the individual-level fit to the organization. Hence, this study investigates whether the positive role of the above factors, in turn, could reduce job distress. Workers from highway service areas in Gyeonggi-do province provided data; 141 valid questionnaires are collected. SPSS 19.0 and AMOS 19.0 were used to test the reliability and validity of constructs. Simple regression, multiple regression, and 3 step mediation tests were used to test the hypotheses after the correlation tests. Results - Results indicated that leader-member contact frequency and psychological distance have negative effects on job distress but positive effects on self-leadership. A mediation test revealed that self-leadership, in the relationships between contact frequency and job distress and between psychological distance and job distress, resulted in partial mediation and full mediation, respectively. Conclusions - The result can be understood through two different possible explanations. First, service area workers generally possess a positive perspective toward their leaders. This can be interpreted to mean that increased contact frequency and psychological distance would be considered as supports from the leader, rather than intrusive controls or management schemes. Therefore, the management in highway service areas should invest efforts in increasing contact frequency as well as maximizing psychological similarities by adopting the viewpoints of workers in terms of moral and ethical management, to reduce the workers' job distress. The results relating to self-leadership also indicate that increased contact frequency must be accompanied by intentions for the effective promotion of workers' self-leadership. It also signifies the necessity of a strategic approach by leaders to induce workers to perceive "in-group"ness as suggested both by the similarity-attraction theory and by the social identity theory. In addition, the results of the mediation test of self-leadership indicate that because workers' self-leadership activates upon increased contact frequency by the leader, it should not be a means of control and should not be utilized only from the perspective of management. It is also suggested that strategies such as transfer of authority could have a positive effect in promoting the expansion of self-influence from workers.

수중 및 공기 중에서의 지르칼로이-4 튜브마멸 비교분석 (Comparison and Analysis of Zircaloy-4 Tube Wear in Air and Water Environment)

  • 김형규;박순종;강흥석;윤경호;송기남
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.19-26
    • /
    • 2001
  • The wear characteristic of Zircaloy-4 tube, which is used for a cladding of light water reactor fuel rod, is investigated experimentally. The experiment is conducted with contacting the crossed tube specimens in air as well as in water at room temperature with various combination of contact normal force and sliding distance of reciprocating motion. The contour and the volume of each wear are examined to study the effect of contact condition and environment on wear. As a result, it is found that the wear volume in the water environment is larger than that in the air for all the contact (i.e., force and sliding distance) conditions. However, the wear depth is greater in air than in water if the contact normal force and the sliding distance are larger. These are explained by the ease of detachment of wear particles from the contact surface. On the other hand, workrate model is applied with the contact shear force range measured by our wear tester. Investigated is the correlation between the workrate and the wear volume increase rate of the present experiment. The parabolic curve is found to fit well for the present wear data.

  • PDF

Predicting the Firmness of Apples using a Non-contact Ultrasonic Technique

  • Lee, Sangdae;Park, Jeong-Gil;Jeong, Hyun-Mo;Kim, Ki-Bok;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제38권3호
    • /
    • pp.192-198
    • /
    • 2013
  • Purpose: Methods for non-destructive estimation of product quality have been reported in various industrial fields, but the application of ultrasonic techniques for the agricultural products of potatoes, pears, apples, watermelons, kiwis and tomatoes etc. have been rarely reported since the application of a contact-type ultrasonic transducer in agricultural products is very difficult. Therefore, this study sought to determine the firmness of apples using non-contact ultrasonic techniques. Methods: For this experiment, an ultrasonic experimental tester using a non-contact ultrasonic transducer was created, and a signal processing program was used to analyze the acquired ultrasonic reflected signal. Also, a universal testing machine was used to measure firmness parameters of the apples such as bioyield strength, a firmness factor, after the ultrasonic tests had been performed. Results: Six distance correction factors were calculated to obtain consistent values of ultrasonic properties regardless of the distance between the transducer and the surface of the subject. We developed prediction models of the bioyield strength using the distance correction factors. Conclusions: The optimum prediction model of the bioyield strength of apples using a non-contact ultrasonic technique was a multiple regression model ($R^2=0.9402$).

Prevalence of dental implant positioning errors: A cross-sectional study

  • Gabriel, Rizzo;Mayara Colpo, Prado;Lilian, Rigo
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.343-350
    • /
    • 2022
  • Purpose: This study evaluated the prevalence of dental implant positioning errors and the most frequently affected oral regions. Materials and Methods: A sample was obtained of CBCT images of 590 dental implants from 230 individuals who underwent diagnosis at a radiology center using cone-beam computed tomography from 2017 to 2020. The following variables were considered: thread exposure, violation of the minimum distance between 2 adjacent implants and between the implant and tooth, and implant contact with anatomical structures. Descriptive data analysis and the Pearson chi-square test(P<0.05) were performed to compare findings according to mouth regions. Results: Most (74.4%) of the 590 implants were poorly positioned, with the posterior region of the maxilla being the region most frequently affected by errors. Among the variables analyzed, the most prevalent was thread exposure (54.7%), followed by implant contact with anatomical structures, violation of the recommended distance between 2 implants and violation of the recommended distance between the implant and teeth. Thread exposure was significantly associated with the anterior region of the mandible (P<0.05). The anterior region of the maxilla was associated with violation of the recommended tooth-implant distance (P<0.05) and the recommended distance between 2 adjacent implants(P<0.05). Implant contact with anatomical structures was significantly more likely to occur in the posterior region of the maxilla (P<0.05). Conclusion: Many implants were poorly positioned in the posterior region of the maxilla. Thread exposure was particularly frequent and was significantly associated with the anterior region of the mandible.

Frictionless contact problem for a layer on an elastic half plane loaded by means of two dissimilar rigid punches

  • Ozsahin, Talat Sukru
    • Structural Engineering and Mechanics
    • /
    • 제25권4호
    • /
    • pp.383-403
    • /
    • 2007
  • The contact problem for an elastic layer resting on an elastic half plane is considered according to the theory of elasticity with integral transformation technique. External loads P and Q are transmitted to the layer by means of two dissimilar rigid flat punches. Widths of punches are different and the thickness of the layer is h. All surfaces are frictionless and it is assumed that the layer is subjected to uniform vertical body force due to effect of gravity. The contact along the interface between elastic layer and half plane will be continuous, if the value of load factor, ${\lambda}$, is less than a critical value, ${\lambda}_{cr}$. However, if tensile tractions are not allowed on the interface, for ${\lambda}$ > ${\lambda}_{cr}$ the layer separates from the interface along a certain finite region. First the continuous contact problem is reduced to singular integral equations and solved numerically using appropriate Gauss-Chebyshev integration formulas. Initial separation loads, ${\lambda}_{cr}$, initial separation points, $x_{cr}$, are determined. Also the required distance between the punches to avoid any separation between the punches and the layer is studied and the limit distance between punches that ends interaction of punches, is investigated. Then discontinuous contact problem is formulated in terms of singular integral equations. The numerical results for initial and end points of the separation region, displacements of the region and the contact stress distribution along the interface between elastic layer and half plane is determined for various dimensionless quantities.

NON-CONTACT SENSORS FOR DETECTING DISTANCE FROM THE FIELD SURFACE

  • Lee, Jeyong-;Minoru-Yamazaki;Akira-oida;Hiroshi-Nakashima;Hiroshi-Shimizu
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.373-382
    • /
    • 1993
  • A non-contact sensor for detecting distance from field surface to a predetermined location of a tractor will be useful to control precise height of implements such as tillage machinery, mowers etc.. An optical and an ultrasonic sensors were designed and fabricated . The indoor and outdoor experiments were conducted to obtain the static and dynamic characteristics of the two sensors at several moisture levels of four soils and on the soil surface with a designed shape. The results revealed that the optical sensor is unsuitable for soils with high moisture content but showed better detecting accuracy on the irregularity of soil surface.

  • PDF