• 제목/요약/키워드: Contact Angle Measurement

검색결과 357건 처리시간 0.024초

나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구 (Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization)

  • 신경인;안선훈;김성훈
    • 한국의류학회지
    • /
    • 제27권5호
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

기하학적 원리에 의거한 접촉각의 측정 (Development of a Contact Angle Measurement Method Based Upon Geometry)

  • 김동수;표나영;서승희;최우진;권영식
    • 자원리싸이클링
    • /
    • 제7권5호
    • /
    • pp.41-45
    • /
    • 1998
  • 간단한 기하학적 원리에 의해 접촉각을 계산할 수 있는 방안을 모색하였다. 접촉각 측정에 일반적으로 이용되는 기기를 사용하지 않고, 단지 고체 표면의 용액 렌즈가 형성하는 접촉원의 지름과 렌즈의 높이를 측정함으로써 상당한 신뢰성을 가진 접촉각의 크기를 계산할 수 있었다. 이 방법의 신뢰성을 확인하기 위하여 동일한 용액 렌즈에 대해 일반적인 접촉각 측정 장치로 접촉각을 측정하여 그 값들을 상호 비교한 결과 오차 한계의 범위내에서 거의 일치함을 확인하였다.

  • PDF

피타고라스 원리를 이용한 정적 접촉각 정밀 각도 측정방법 (Precise Static Contact Angle Measurements Using Pythagolas Rule)

  • 최진영;권동준;왕작가;신평수;박종만
    • 접착 및 계면
    • /
    • 제15권2호
    • /
    • pp.57-62
    • /
    • 2014
  • 피타고라스 원리를 이용하면 특정 도형이 보유하고 있는 각도에 대한 계산이 용이해진다. 정적 접촉각 평가방법을 이용할 경우 용액과 고체 물체간의 접촉각의 수치 계산이 가장 중요한 부분이다. 용액과 고체 표면이 이루는 각도 측정을 용이하게 하기 위해서 접촉각을 계산하는 방법을 규격화하는 방법과 접촉각 평가에 따른 실험적 변수 최소화 조건을 마련하였다. 접촉각 실험을 위한 용액의 직경에 따른 접촉각의 각도 계산 오차를 분석하고, 최적의 물방울 직경은 1 mm임을 확인하였다. 피타고라스 원리를 이용한 접촉각 측정방법은 전진각과 후진각을 확인하는데 사용할 수 있으며, 소수성 및 친수성 표면을 분석하는데 적용이 가능하였다. 궁극적으로 일반적인 접선 긋기를 통한 각도 계산 결과보다 피타고라스 원리를 이용하여 접촉각 각도 계산을 실시할 경우 비교적 정확한 접촉각 계산 결과를 확인할 수 있었다.

Measurement of Dynamic Contact Angle of Yarn for Evaluation of Fabric Comfort Performance

  • Hong, Cheol-Jae
    • 감성과학
    • /
    • 제5권3호
    • /
    • pp.67-74
    • /
    • 2002
  • Testing device was newly designed and built to measure the dynamic contact angle. The measurement was made using microscope interfaced with computerized image analysis system while the dynamic condition being controled using Instron. As specimens for the experiment, two different types of fibers, i.e., hydrophilic and hydrophobic, were prepared. In case of hydrophilic fiber, the increase of twist level gave the increase of contact angle. However, in hydrophobic yarn the increase of twist level gave the decrease of contact angle. When saline was used as a telling liquid, the increase of the concentration gave the increase of contact angle. The results rationalized clearly on the basis of known concepts could be used in designing fabric structure for the improvement of comport performance.

  • PDF

Feasibility study on the contact angle measurement by laser beam projection

  • Ahn, Seon-Hoon;Kim, Seong-Hun;Shin, Kyung-In;IM, Seung-Soon
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.103-103
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. From the result of comparative experiment and questionnaire, the laser contact angle.

  • PDF

미소 액적의 접촉각 및 건조 특성 측정 시스템 개발 (Development of Measurement System for Contact Angle and Evaporation Characteristics of a Micro-droplet on a Substrate)

  • 권계시;안승현;장민혁
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.414-420
    • /
    • 2013
  • We developed inkjet based measurement system for micro-droplet behavior on a substrate. By using the inkjet dispenser, a droplet, which is as small as few pico-liter in volume, can be jetted and the amount can be controlled. After jetting, the droplet image on the substrate is acquired from side view camera. Then, droplet profile is extracted to measure droplet volume, contact angle and evaporation characteristics. Also top view image of the droplet is acquired for better understanding of droplet shape. The previous contact angle measurement method has limitations since it mainly measures the ratio of height and contact diameter of droplet on a substrate. Unlike previous measurement system, our proposed method has advantages because various behavior of droplet on substrate can be effectively analyzed by extracting the droplet profile.

접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 - (Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle -)

  • 이찬용;김철환;최경민;박종열;권오철
    • 펄프종이기술
    • /
    • 제35권3호
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

접촉각측정에 의한 표면의 특성연구 - I. 레이저광선 투영에 의한 접촉각의 측정방법- (Characterization of Surfaces by Contact Angle Goniometry - I. Contact Angle Measurement by Laser Beam Projection-)

  • 박정희
    • 한국의류학회지
    • /
    • 제15권1호
    • /
    • pp.70-75
    • /
    • 1991
  • 본 연구에서는 레이저광선의 투영을 이용한 접촉각측정기구가 개발되었다. 이 새로운 방법은 편평한 표면분만 아니라 직격이 가는 섬유를 포함한 굴곡진 표면에서는 stationary, advancing그리고 receding contact angle-을 신속하고 정확하게 측정할 수 있게 하여 준다. 가는 레이저광선이 액체와 고체사이 계면의 끝을 통과하여 tangent screen의 각도를 재는 눈금상에 중심으로부터 방사상으로 두개의 선이 나타나게 된다. 이때 눈금상에 투영된 두개의 레이저광선 사이의 각도를 접촉각으로 결정한다. 이 새로운 기구를 사용한 결과, PMMA(Perspex-CQ)상에서의 접촉각은 문헌상의 접촉각과 일치함으로써 간편하고 정확한 접촉각 측정법임을 입증할 수 있었다.

  • PDF

CO2 가스의 존재 여부와 용액의 pH가 Silica/Pb(II) 용액 계면에서 Silica 표면의 특성에 미치는 영향 (Effects of pH and the Existence of CO2 Gas on the Silica Surface Characteristics at Silica/Pb(II) Solution Interface)

  • 이상은
    • 한국토양비료학회지
    • /
    • 제36권5호
    • /
    • pp.263-271
    • /
    • 2003
  • $CO_2$ 가스 존재여부와 pH가 Pb(II)와 sodium dodecyl sulfonate(SDS, $C_{12}H_{25}SO_3Na$) 흡착에 따른 silca 표면의 특성 변화에 미치는 영향을 contact angle 과 AFM을 이용한 힘 측정을 통하여 살펴보았다. 대기와 접촉하여 $CO_2$가 용해되는 조건에서 Pb와 SDS가 $10^{-4}M$ 씩 들어 있는 혼합용액을 처리하였을 때, fused silica 표면의 contact angle은 $PbCO_3$의 침전 때문에 최대 $46^{\circ}$로 낮았다. 반면에 $N_2$ 개스를 불어넣는 $CO_2$ 부재조건에서는 $PbCO_3$의 침전이 없었기 때문에 contact angle이 최대 $90^{\circ}$로 크게 증가되었다. $CO_2$ 부재조건에서 pH에 따른 contact angle과 AFM에서 측정한 점착력($F_{ad}$) 변화 양상은 $PbOH^+$ 화학종 분포와 유사하였으므로, Pb(II)의 silica 표면 흡착형태는 $PbOH^+$ 로 판단되었다. 한편 contact angle 과 AFM 측정결과 모두 Pb 단독처리에서 소수성을 발현하였다. 이 결과는 현재까지의 알려진 이론으로 설명할 수 없었으며 이를 위하여 원자수준에서의 심도 깊은 연구가 필요하다고 판단되었다.

접촉각 측정에 의한 표면의 특성연구( II ) -섬유나 막대의 직경이 접촉각에 미치는 영향- (Characterization of Surfaces by Contact Angle Goniometry - II . Effect of Curvature on Contact Angle -)

  • 박정희
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.437-445
    • /
    • 1991
  • The effect of diameter of rods or fibers on contact angle was studied in a vertical rod configuration. A contact angle measuring device described in the previous paper was optimized for the measurement of small-diameter fibers. It was shown that contact angles of water and hexadecane on nylon 6 monofilsments and glass rods increased with decrease of diameter below a critical diameter, which varied from one system to another. Beyond the critical value, contact angle of the liquid on the vertical glass rod reached to an equilibrium value which is equal to the unique value of the contact angle of the liquid drop on the horizontal glass plate.

  • PDF