• Title/Summary/Keyword: Construction stage

Search Result 2,336, Processing Time 0.024 seconds

A study on performance evaluation of fiber reinforced concrete using PET fiber reinforcement (PET 섬유 보강재를 사용한 섬유 보강 콘크리트의 성능 평가에 관한 연구)

  • Ri-On Oh;Yong-Sun Ryu;Chan-Gi Park;Sung-Ki Park
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.4
    • /
    • pp.261-283
    • /
    • 2023
  • This study aimed to review the performance stability of PET (Polyethylene terephthalate) fiber reinforcing materials among the synthetic fiber types for which the application of performance reinforcing materials to fiber-reinforced concrete is being reviewed by examining short-term and long-term performance changes. To this end, the residual performance was analyzed after exposing the PET fiber to an acid/alkali environment, and the flexural strength and equivalent flexural strength of the PET fiber-reinforced concrete mixture by age were analyzed, and the surface of the PET fiber collected from the concrete specimen was examined using a scanning microscope (SEM). The changes in were analyzed. As a result of the acid/alkali environment exposure test of PET fiber, the strength retention rate was 83.4~96.4% in acidic environment and 42.4~97.9% in alkaline environment. It was confirmed that the strength retention rate of the fiber itself significantly decreased when exposed to high-temperature strong alkali conditions, and the strength retention rate increased in the finished yarn coated with epoxy. In the test results of the flexural strength and equivalent flexural strength of the PET fiber-reinforced concrete mixture, no reduction in flexural strength was found, and the equivalent flexural strength result also did not show any degradation in performance as a fiber reinforcement. Even in the SEM analysis results, no surface damage or cross-sectional change of the PET reinforcing fibers was observed. These results mean that no damage or cross-section reduction of PET reinforcing fibers occurs in cement concrete environments even when fiber-reinforced concrete is exposed to high temperatures in the early stage or depending on age, and the strength of PET fibers decreases in cement concrete environments. The impact is judged to be of no concern. As the flexural strength and equivalent flexural strength according to age were also stably expressed, it could be seen that performance degradation due to hydrolysis, which is a concern due to the use of PET fiber reinforcing materials, did not occur, and it was confirmed that stable residual strength retention characteristics were exhibited.

Mitigation of Insufficient Capacity Problems of Central Bus Stops by Controlling Effective Green Time (유효녹색시간 조정을 활용한 중앙버스정류장 용량 부족 완화 방안 연구)

  • Koo, Kyo Min;Lee, Jae Duk;Ahn, Se Young;Chang, Iljoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.1
    • /
    • pp.35-50
    • /
    • 2022
  • After the introduction of the central bus lane system, bus traffic was prioritized. This resulted in improved trust from bus users. However, the low capacity at the central bus stop reduces traffic speed and punctuality. In addition, physical constraints are inevitable because the construction of central bus lanes and bus stops considers the city's road geometry. Therefore, this study attempted to optimize the effective green time of the traffic signal system at the entrance and exit of the central bus stop to remedy its insufficient operational capacity. The Transit Capacity and Quality of Service Manual and Korea Highway Capacity Manual were used as the analysis methodologies. The number of stop areas for central bus stops to be built was determined by excluding variable physical factors, and field survey data collected from nine randomly selected central bus stops currently installed in Seoul were used. A scenario analysis was conducted on the central bus stops with insufficient capacity by adjusting the effective green time, and the capacity of the central bus stop was set as the dependent variable. According to the results, 26.7 percent of the central bus stops with insufficient capacity can solve the problem of insufficient capacity. Therefore, the results of this study can be verified by improving the operation level, and it can be effective even if the number of central bus stops calculated by engineering is not guaranteed during the planning stage of the central bus stop. As the number of central bus stops is expected to increase further as the number of central bus stops increases, it is necessary to improve the number of central bus stops. Therefore, it is hoped that the results presented in this study will be used as basic data for the improvement plan at the operational level before introducing the physical improvement plan.

A Study on the Needs Analysis of University-Regional Collaborative Startup Co-Space Composition (대학-지역 연계 협업적 창업공간(Co-Space) 구성 요구도 분석)

  • Kim, In-Sook;Yang, Ji-Hee;Lee, Sang-Seub
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.1
    • /
    • pp.159-172
    • /
    • 2023
  • The purpose of this study is to explore a collaborative start-up space(Co-Space) configuration plan in terms of university-regional linkage through demand analysis on the composition of university-regional linkage startup space. To this end, a survey was conducted for request analysis, and the collected data were analyzed through the t-test, The Lotus for Focus model. In addition, FGI was implemented for entrepreneurs, and the direction of the composition of the university-region Co-Space was derived from various aspects. The results of this study are as follows. First, as a result of the analysis of the necessity of university-community Co-Space, the necessity of opening up the start-up space recognized by local residents and the necessity of building the start-up space in the region were high. In addition, men recognized the need to build a space for start-ups in the community more highly than women did women. Second, as a result of analysis of demands for university-regional Co-Space, the difference between current importance and future necessity of university-regional Co-Space was statistically significant. Third, as a result of analysis on the composition of the startup space by cooperation between universities and regions, different demands were made for composition of the startup space considering openness and closeness, and for composition of the startup space size. The implications of the study are as follows. First, Co-Spaces need to be constructed in conjunction with universities in accordance with the demands of start-up companies in the region by stage of development. Second, it is necessary to organize a customized Co-Space that takes into account the size and operation of the start-up space. Third, it is necessary to establish an experience-based open space for local residents in the remaining space of the university. Fourth, it is necessary to establish a Co-Space that enables an organic network between local communities, start-up investment companies, start-up support institutions, and start-up companies. This study is significant in that it proposed the regional startup ecosystem and the cooperative start-up space structure for strengthening start-up sustainability through cooperation between universities and local communities. The results of this study are expected to be used as useful basic data for Co-Space construction to build a regional start-up ecosystem in a trend emphasizing the importance of start-up space, which is a major factor affecting start-up companies.

  • PDF

Bloom-forming Cyanobacteria in Yongdam Lake (1) Nutrient limitation in a Laboratory Strain of a Nitrogen-fixing Cyanobacterium, Anabaena spiroides v. crassa (용담호 녹조현상의 원인 남세균 연구 (1) 질소고정 남세균 Anabaena spiroides v. crassa 종주와 영양염 제한)

  • Park, Jong-Woo;Kim, Young-Geel;Heo, Woo-Myung;Kim, Bom-Chul;Yih, Won-Ho
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.11 no.4
    • /
    • pp.158-164
    • /
    • 2006
  • Yongdam Lake is the fifth largest artificial lake in Korea newly formed by the first impounding the Yongdam Multi-purpose Dam on December, 2002. Yongdam Lake, with her total water storage of 820 million M/T, is located at the roof-top region of the streams flowing into the just-constructed new Saemankeum Lake. Seasonal succession of phytoplakton in Yongdam Lake might affect cyanobacterial blooms in Saemankeum Lake by inoculating seasonal dominants. During 2002-2003 when the first impounding after the construction of Yongdam Multi-purpose Dam was still undergoing, summer cyanobacterial blooms by Anabaena, Microcystis, and Aphanizomenon were observed. Among these three, filamentous Anabaena is well known to have its species with $N_2-fixing$ ability and special cells such as heterocysts and akinetes as well as the vegetative cells. We established a clonal culture of Anabaena spiroides v. crasse (KNU-YD0310) from the live water samples collected at the bloom site of Yongdam Lake. The N- and P-nutrient requirement of the KNU-YD0310 was explored by the experimental cultivation of the laboratory strain. Ratio of heterocysts to vegetative cells increased as N-deficiency extended with its maximum at $N_2-fixing$ condition. The strain KNU-YD0310 exhibited considerable growth under N-limiting conditions while its growth was proportional to the initial phosphate-P concentration under P-deficient conditions. Under P-limiting conditions akinete density increased, which could be interpreted as an adaptation strategy to survive severe environment by transforming into resting stage. The above eco-physiological characteristics of Anabaena spiroides v. crassa might be useful as an ecological criterion in controlling cyanobacterial blooms at Shaemankeum Lake in near future.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

A Methodology to Develop a Curriculum based on National Competency Standards - Focused on Methodology for Gap Analysis - (국가직무능력표준(NCS)에 근거한 조경분야 교육과정 개발 방법론 - 갭분석을 중심으로 -)

  • Byeon, Jae-Sang;Ahn, Seong-Ro;Shin, Sang-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.1
    • /
    • pp.40-53
    • /
    • 2015
  • To train the manpower to meet the requirements of the industrial field, the introduction of the National Qualification Frameworks(hereinafter referred to as NQF) was determined in 2001 by National Competency Standards(hereinafter referred to as NCS) centrally of the Office for Government Policy Coordination. Also, for landscape architecture in the construction field, the "NCS -Landscape Architecture" pilot was developed in 2008 to be test operated for 3 years starting in 2009. Especially, as the 'realization of a competence-based society, not by educational background' was adopted as one of the major government projects in the Park Geun-Hye government(inaugurated in 2013) the NCS system was constructed on a nationwide scale as a detailed method for practicing this. However, in the case of the NCS developed by the nation, the ideal job performing abilities are specified, therefore there are weaknesses of not being able to reflect the actual operational problem differences in the student level between universities, problems of securing equipment and professors, and problems in the number of current curricula. For soft landing to practical curriculum, the process of clearly analyzing the gap between the current curriculum and the NCS must be preceded. Gap analysis is the initial stage methodology to reorganize the existing curriculum into NCS based curriculum, and based on the ability unit elements and performance standards for each NCS ability unit, the discrepancy between the existing curriculum within the department or the level of coincidence used a Likert scale of 1 to 5 to fill in and analyze. Thus, the universities wishing to operate NCS in the future measuring the level of coincidence and the gap between the current university curriculum and NCS can secure the basic tool to verify the applicability of NCS and the effectiveness of further development and operation. The advantages of reorganizing the curriculum through gap analysis are, first, that the government financial support project can be connected to provide quantitative index of the NCS adoption rate for each qualitative department, and, second, an objective standard is provided on the insufficiency or sufficiency when reorganizing to NCS based curriculum. In other words, when introducing in the subdivisions of the relevant NCS, the insufficient ability units and the ability unit elements can be extracted, and the supplementary matters for each ability unit element per existing subject can be extracted at the same time. There is an advantage providing directions for detailed class program and basic subject opening. The Ministry of Education and the Ministry of Employment and Labor must gather people from the industry to actively develop and supply the NCS standard a practical level to systematically reflect the requirements of the industrial field the educational training and qualification, and the universities wishing to apply NCS must reorganize the curriculum connecting work and qualification based on NCS. To enable this, the universities must consider the relevant industrial prospect and the relation between the faculty resources within the university and the local industry to clearly select the NCS subdivision to be applied. Afterwards, gap analysis must be used for the NCS based curriculum reorganization to establish the direction of the reorganization more objectively and rationally in order to participate in the process evaluation type qualification system efficiently.