• Title/Summary/Keyword: Construction Safety Accident

Search Result 803, Processing Time 0.018 seconds

A Study on the Model Regulation's Improvement for Control of Aeronautical Obstacles in Korea (항공장애물관리규정 개선을 위한 연구)

  • Lee, Kang-Seok
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.3 s.81
    • /
    • pp.21-34
    • /
    • 2005
  • To control the obstacles surrounding aerodrome is significant for preventing air accident and ensuring the long sustaining of aerodromes. On the other hand, within a scope of ensuring safe flight operations, the application of Shielding is one of the issues to be importantly considered to manage efficiently the obstacles limitation around aerodromes, to dissolute the private asset privilege limitation from regulation on aerodrome circumference, and to decrease the pains to manage the obstacles, in terms of not only operating safely but also utilizing efficiently the airspace around aerodromes. The ICAO and other aviation-advanced states mitigate the construction limitation or exempt the obligation of obstacle sign by applying the shielding theory that the obstacles are not regarded as obstacles where are below the shadow surface. The Republic of Korea inserted the new regulation including the applying shielding similar to ICAO on Aviation Act and regulations. It is, however, hard to manage the aviation obstacles around aerodrome efficiently with these new regulation. Particularly, there exists much rooms to dispute because it cannot suggest the specific standard which is necessary to apply shielding theory at airspace of aerodromes. Therefore, in this study, the international standards on aviation obstacles were reviewed, analyzed and compared with those of domestic status. The direction of which guideline for control of aeronautical obstacles applicable within domestic circumstances as well as correspondent with international standard was suggested. Particularly, as far as the disputable application of shielding theory is concerned, the alternatives for aviation safety and efficient airspace operation by suggesting the clear standards alternatives were suggested.

Firefighters' Exposures to Polynuclear Aromatic Hydrocarbons and Volatile Organic Compounds by Tasks in Some Fire Scenes in Korea (일부 화재현장에서 소방공무원의 직무별 다핵방향족탄화수소 및 휘발성유기화합물 노출평가)

  • Jin, Suhyun;Byun, Hyaejeong;Kang, Taesun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.477-487
    • /
    • 2019
  • Objectives: Firefighters are known to be exposed to a variety of toxic substances, but little information is available on the exposure profile of firefighting activities. The aims of this study were to conduct exposure monitoring of toxic chemicals at fire scenes, to compare the concentrations of respective chemicals among firefighting tasks, and to assess the main factors influencing the concentrations of chemicals. Methods: Researchers performed sampling at firefighting scenes during four weeks in 2013. At the scene, we collected samples based on firefighters' own activities and examined the situation and scale of the accident. Collected samples were classified into three categories, including fire extinguishing and overhaul, and were analyzed in the laboratory according to respective analysis methods. Results: A total of fourteen fire activity events were surveyed: five fire extinguishing, six overhaul, and three fire investigations. Although no substance exceeded the ACGIH TLV, PAHs were detected in every sample. Naphthalene ranged from 0.24 to 279.13 mg/㎥ (median 49.6 mg/㎥) and benzo(a)pyrene was detected in one overhaul case at 10.85 ㎍/㎥. Benzene (0.01-12.2 ppm) was detected in every task and exceeded the ACGIH TLV. No significant difference in concentrations between tasks was shown. Conclusions: These results indicate that all firefighting tasks generated various hazardous combustion products, including possible carcinogens.

Structural Behavior of Slab in the Partial Demolition for the Apartment Remodeling (아파트 리모델링을 위한 부분해체에서 슬래브의 구조적 거동)

  • Choi, Hoon;Joo, Hyung Joong;Kim, Hyo Jin;Yoon, Soon Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.19-30
    • /
    • 2012
  • Due to the fact that the social environment is improved and the urban development is stabilized, the demand of new construction of apartment becomes slowdown. Accordingly, there are many researches to lengthen the service life of the existing apartment through the remodeling and its importance is continuously rising. However, reliable design specifications and guidelines for the design of remodeling with partial demolition are not provided yet in Korea. Specially, in the apartment remodeling, slab collapse accidents take major portion in all accidents that reported by Korean Government. It is very important to prevent intial crack of slab because intial crack could cause severe accident like collapse of all structure in a short period of time. The purpose of this study is to develop structural guidelines that could guarantee the structural safety and serviceability of slab structure and could be adopted in Korean remodeling with partial demolition. There are mainly two components to determine structural behavior of slab structure. One is the shape of slab structure and the other is load which is resisted by the slab structure. In this study, the weight per unit volume of concrete debris and concrete strength are estimated through the analysis of previous researches to recognize the relationship between the shape of slab and load that loaded on the slab. Accordingly, approximately 300 pieces of floor plan are collected and analyzed. The finite element analysis is conducted using these analyzed and estimated results. From the finite element analysis results, the limited stacking height of debris is suggested and the stacking method is also discussed. In addition, to find the relationship between movement of demolition equipment and structural behavior of slab, the static and dynamic loading tests are conducted. From the results of loading tests, the impact factor which will be considered in the remodeling design could be estimated.