• Title/Summary/Keyword: Construction R&D Results

Search Result 366, Processing Time 0.026 seconds

Study on key safety hazards and risk assessments for small section utility tunnel in urban areas (도심지 소단면 터널식 공동구의 핵심 안전 위험요소 및 위험성 평가 연구)

  • Seong, Joo-Hyun;Jung, Min-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.931-946
    • /
    • 2018
  • In line with the increased usability of utility pipe conduits in urban areas, construction and R&D activities of utility tunnel, incorporated with the shield TBM method, are actively under way. The utility tunnels are installed through underground excavation, and thus are relatively weak in terms of construction safety. However, hazards associated with the utility tunnel construction have not been properly identified, despite the introduction of a policy to the 'Design for Safety' for the purpose of reducing accident rates in the construction industry. Therefore, in this study, following the derivation of hazards associated with utility tunnel, these hazards were then used as the basis to uncover key safety hazards requiring extensive management in a field, which were then used to conduct a risk assessment having applied the matrix method so that the results can be utilized in risk assessment during the stages of utility tunnel planning, design, and construction, while also serving as a data reference.

Effects of Curing Temperature on the Unconfined Compressive Strength of Lime Soil Mixtures (양생온도(養生溫度)가 석회혼합토(石灰混合土)의 압축강도(壓縮强度)에 미치는 영향(影響))

  • Kim, Jae Young;Kang, Yea Mook;Kim, Sung Wan
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.433-444
    • /
    • 1975
  • This study was conducted to investigate the strength of lime soil mixtures for varied' curing temperatures(20, 30, 40, 50, $60^{\circ}C$) and lime content (3, 6, 9, 12%) in four lime-stabilized soils(KY : Sand, MH : Sand, SS: Sandy loam. JJ : Loam). The experimental results obtained from unconfined compressive strength tests are as follows; 1. The optimum moisture content increased and maximum dry density decreased with the increase of the lime content. 2. The lime content for the maximum strength of SS and JJ soils showed at the 9 percent lime content, but KY and MH soils didn't show the tendency of increase and decrease by the lime content and curing period. The rate of decrease of the soaked unconfined compressive strength showed the lower value in accordance with lime content. 3. According to increase in curing temperatures in curing temperatures at 30, 40, 50, $60^{\circ}C$, the unconfined compressive strength of lime soil mixtures increased, the rate of increase initially increased at a rapid rate, and showed that around 120 hours were sufficient curing time to complete hardening. 4. The average maximum temperature of Korea being around $30^{\circ}C$ from July to August, thus these months are ideal construction periods to increase the strehgth of lime soil mixtures. 5. Accelerated curing times equivalent to 28-day normal curing decreased in accordance with the increase of curing temperature, and showed shorter in lime soil mixtures than soil cement. 6. Accelerated curing times versus normal curing times are formed as a linear, its slope decreased in accordance with the increase of curing temperature, it may be expressed as follows: (1). $30^{\circ}C$ : t=2.63d-1.4(r=0.99) (2). $40^{\circ}C$ : t= 1.76d-0.8(r=0.97) (3). $50^{\circ}C$ : t=1.35d-3.2(r=0.94) (4). $60^{\circ}C$ : t=0.49d+1.8(r=0.91) in which t ; Accelerated curing time d ; Normal curing time.

  • PDF

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

Molecular phylogenetic relationships within the PSP producing marine dinoflagellate, genus Alexandrium

  • Kim, Choong-jae;Kim, Sook-Yang;Kim, Kui-Young;Kang, Young-Sil;Kim, Hak-Gyoon;Kim, Chang-Hoon
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.136-137
    • /
    • 2003
  • The marine dinoflagellate genus Alexandrium has been recognized as the most representative toxic phytoplankton on account of production of paralytic shellfish poisoning (PSP) throughout the world. PSP producers, generally A, tamarense and A. catenella, within the genus Alexandrium have caused high level intoxicauon of fisheries products and even death of human. In addition, more recent increasing of geographical range of this deleterious species has given rise to alarming tension. The study presented here aimed construction of the molecular phylogenetic relationships through sequences-determination from 16 morphotypic species (containing newly sequenced 3 morphotypic species, A. tamiyavainchii, A. fraterculus and A. pseudogonyaulax) in LSU rDNA D1-D2 and 12 morphotypic species (containing newly sequenced 6 - morphotypic species, A. catenella, A. tamiyavanichii, A. fraterculus, A. affine, A. insuetum and A. pseudogonyaulax) in SSU rDNA region, and the sequences were subjected to comparative-analysis in respect to regional population using functionally expressed rDNA genus and pseudogenes. And we discussed on genetic differentiation between A. tamarense and A. catenella together with putative PSP divegence of the genus Alexandrium. The results of phylogenetic analysis showed the robust monophyletic 14 distinct classes of A. tamarense, A. excavatum, A. catenella, Tasmanian A. tamarense, A. affine (and/or A. concavum), Thai A. tamarense, A. tamiyavanichii, A. fraterculus, A. margalefii, A. andersonii, A. ostenfeldii, A. minutum (and/or A. lusitanicum), A. insuetum, and A, pseudogonyaulx clade. A. fraterculus and A. tamiyavanichii were sister relationship and they were positioned independently between A, affine cluster and those of A. margalefi, A. andersonii, A. ostenfeldii, A. minutum and A. insuetum. A. pseudogonyaulax appeared to be an ancestral taxon among Alexandrium.

  • PDF

Effect of Fiber Content, Yarn Size and Construction of Knit Fabrics on the Buffering Capacity against Water Vapor (편성물의 섬유의 종류, 실의 굵기 및 니트타입에 따른 투습완충능력)

  • Yoo, Hwa-Sook;Hu, Yoon-Sook;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.1
    • /
    • pp.228-238
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of chacteristics of knit fabrics on the microclimate of the skin simulating system. To determine the effect of characteristics of knit fabrics, vapor state of sweat pulse was simulated in the closed system. Different contents of fibers such as cotton, wool and polyester with different yarn size and knit types were chosen for specimens. The changes of humidity and temperature of air layer in the simulated systems were measured. Buffering indices, $K_d$ and $\beta_r$, were determined by considering $\alpha_p, \DeltaP_{max}, t_{max}, and tan\beta$. Physical properties of knit fabrics such as thickness, porosity, air resistance and moisture vapor transport were measured. Results showed that vapor pressure of wool was lower than cotton or polyester This was attributed to the hydrophilicity of wool which absorbed moisture rather quickly and retained in the knit fabric. The time to decrease vapor pressure was faster for polyester than cotton or wool. As a result, $K_d$ was in the order of wool> polye, item> cotton. $\beta_r$ of wool was rower than cotton or polyester due to its lowers porosity and slower desorption rate. For the yarn size, $K_d$ was in the order of 80's> 60's> 30's; thinner and lighter yarn showed better water vapor transport property. For knit type, buffering capacity of single jersey was better than interlock knit fabric. Statistical analysis showed that the air permeability was the most influential factor far the water vapor transport properties.

  • PDF

A Performance Evaluation of a 400RT Vertical type Geothermal System installed in a R&D and Office Building in Spring (연구.사무공간의 냉난방용으로 설치된 400RT급 수직형 지열시스템의 봄철 성능평가)

  • Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Hwang, Kwang-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.4 no.2
    • /
    • pp.9-14
    • /
    • 2008
  • 400RT geothermal system which is consist with vertical-typed 112 geothermal heat exchangers is measured and evaluated in spring, 21st${\sim}$24th May 2008. As the results, the average temperature difference between inlet and outlet of geothermal pipes is $1{\sim}2^{\circ}C$ and that of cool water supply is $2{\sim}6^{\circ}C$, when being normally operated. Despite temperature fluctuations by cooling loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $3^{\circ}C$. The geothermal system COPs are calcluated as 2.92${\sim}$3.92 in every 12 hours.

  • PDF

A Study on the Decision of Appropriate Subsidy Levels for Energy Storage Systems Considering Load Leveling in Smart Place (부하평준화 기능을 고려한 주택용 ESS의 적정 지원금 산정에 관한 연구)

  • Kim, Jung-Hoon;Hwang, Sung-Wook;Lee, Hak-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.211-216
    • /
    • 2014
  • Construction of power plants and T&D facilities is so difficult because of the civil complaints and the additional cost according to the concerning field conditions. Therefore, various researches and methods have been considered to get solutions in the demand side and energy storage systems have been in the spotlight because of the various functions such as peak shaving, load shifting, and power system stabilizing, and so on. Residential small size batteries are considered in this paper and the economic analysis is carried out to evaluate the reasonable subsidy levels for the deployment of energy storage systems. Various economic parties are considered to find reasonable subsidy level comparing each other, which parties consist of utilities, participants and non-participants in general. The evaluation is based on California Standard Practice Test and the results are able to be used as subsidy guidelines.

A Study on Objective Quality Assessment for Synthesized speech by Rule (규칙합성음의 객관적 품질평가에 관한 연구)

  • 홍진우;김순협
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.10
    • /
    • pp.42-49
    • /
    • 1993
  • In this paper, we evaluate the quality of synthesized speech by rule using the LPC CD as a objective measure, and then compare the test result with the subjective one. Speech used for the test consists of 108 words which are selected by word construction method using Korean attribute and frequency distribution, synthesized by demi-syllable rule. By evaluating the quality of synthesized speech by reule objectively, we have tried to resolve the problems such as lots of evaluation time, expansion of test scale, and variables of analysis result arised by subjective measure. We have, also, proved the validity of the objective test using the LPC CD, by comparing intelligibility which is the index for the subjective quality evaluation of synthesized speech by rule with MOS. From this results, we can provide a guide for quality assessment that would be useful in the R&D of synthesis method and the commercial products using synthesized speech.

  • PDF

Optimization of Rotor Blade Stacking Line Using Three Different Surrogate Models

  • Jang, Choon-Man;Samad, Abdus;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.22-31
    • /
    • 2007
  • This paper describes the shape optimization of rotor blade in a transonic axial compressor rotor. Three surrogate models, Kriging, radial basis neural network and response surface methods, are introduced to find optimum blade shape and to compare the characteristics of object function at each optimal design condition. Blade sweep, lean and skew are considered as design variables and adiabatic efficiency is selected as an objective function. Throughout the shape optimization of the compressor rotor, the predicted adiabatic efficiency has almost same value for three surrogate models. Among the three design variables, a blade sweep is the most sensitive on the object function. It is noted that the blade swept to backward and skewed to the blade pressure side is more effective to increase the adiabatic efficiency in the axial compressor Flow characteristics of an optimum blade are also compared with the results of reference blade.

Construction of recombinant DNA clone for bovine viral diarrhea virus (소 바이러스성 설사병 바이러스의 유전자 재조합 DNA clone의 작성에 관한 연구)

  • Yeo, Sang-geon;Cho, H.J.;Masri, S.A.
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.389-398
    • /
    • 1992
  • Molecular cloning was carried out on the Danish strain of bovine viral diarrhea virus(BVDV) to construct strategy for the diagnostic tools and effective vaccine of BVD afterwards. A recombinant DNA clone(No. 29) was established successfully from cDNA for viral RNA tailed with adenine homopolymer at 3'-end. $^{32}P$-labeled DNA probes of 300~1,800bp fragments, originating from the clone 29, directed specific DNA-RNA hybridization results with BVDV RNA. Recombinant DNA of the clone 29 was about 5,200bp representing 41.6% of the full length of Danish strain's RNA, and restriction sites were recognized for EcoR I, Sst I, Hin d III and Pst I restriction enzymes in the DNA fragment.

  • PDF