Analysis and Control of an Unsymmetrical 3-Phase VR Type Self Bearing Step Motor (비대칭 3상 가변형 셀프 베어링 스텝모터의 해석 및 제어)

  • Kim, Dae-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.806-811
    • /
    • 2001
  • The analysis and control algorithm of a new type unsymmetrical self-bearing step motor is presented. The motor actuator is used for both motor and bearing functionality without any redundant coil windings or redudant electromagnets for bearing functionality. Self bearing step motor layout and control current generation method for unsymmetrical position of electromagnets are described. This new current generation method without additional current for bearing functionality leads to minimize the power loss. As the result of the unbalance response approach, the constant torque is possible, even though the bearing functionality is added or not.

  • PDF

Sliding Mode Current Controller Design for Power LEDs

  • Kim, Eung-Seok;Kim, Cherl-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.104-110
    • /
    • 2011
  • High-brightness LED control is required for stable operation, thus the driver and control system must be designed to deliver a constant current to optimize reliability and ensure consistent luminous flux. In this paper, the sliding mode current controller is designed to adjust the illumination density of power LEDs. The controller design model of power LEDs, including its driving circuit, is proposed to realize the dimming control of power LEDs. A buck converter is introduced to drive the power LEDs and reduce the input voltage to a lower level. The sliding mode software controller is implemented to adjust the dimming of power LEDs. The proposed strategy for driving power LEDs is investigated and comparatively studied by experiments.

Control Scheme of Emergency Power Supply for Elevator Emergency Call System (승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로)

  • Park, Noh-Sik;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

Space Vector PWM Method for Leakage Current Reduction and NP Current Control in 3-phase 3-level Converter used in Bipolar DC Distribution System (양극성 DC 배전용 3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 공간벡터 PWM 방법)

  • Lee, Eun-Chul;Choi, Nam-Sup;Kim, Hee-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.336-344
    • /
    • 2018
  • This study proposes a new PWM method for leakage current reduction and neutral point (NP) current control in three-phase three-level converter employed in bipolar DC distribution systems. The proposed PWM method uses medium vectors only when there is no need to control the NP current. Thus, common mode voltages are held constant to realize zero leakage current. Some space vectors that produce low-frequency common mode voltages are employed to minimize leakage currents when the average NP current needs to be a positive or negative value. The proposed space vector PWM is implemented based on barycentric coordinate. The validity of the proposed PWM method is verified by simulations and experiments.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Time-Delay Effects on DC Characteristics of Peak Current Controlled Power LED Drivers

  • Jung, Young-Seok;Kim, Marn-Go
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.715-722
    • /
    • 2012
  • New discrete time domain models for the peak current controlled (PCC) power LED drivers in continuous conduction mode include for the first time the effects of the time delay in the pulse-width-modulator. Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between the two conduction modes. Especially, the time delay can provide an accurate LED current for the PCC buck converter with a wide input voltage. The models can also predict the critical inductor value at the mode boundary as functions of the input voltage and the time delay. The overshoot of the peak inductor current due to the time delay results in the increase of the average output current and the reduction of the critical inductor value at the mode boundary in all converters. Experimental results are presented for the PCC buck LED driver with constant-frequency controller.

Indirect Cutting Force Measurement and Cutting Force Regulation Using Spindle Motor Current (주축모터 전류를 통한 절삭력의 간접 측정 및 절삭력 추종제어)

  • Kim, Gi D.;Kwon, Won T.;Chu, Chong N.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.15-27
    • /
    • 1997
  • Quasti-static cutting force variations in milling process are measured indirectly using spindle motor current. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Magnitude of the spindle motor current is independent of cutting direction. The linear relationship between the cutting force and the spimdle motor RMS current at various spindle rotational speed is obtained. Frequency/ Voltage(F/V) converter voltage is measured to identify the spindle speed and to determine the cutting force at various spindle speeds. Overload on the tool during milling process can be detected using the proposed indirect cutting force measurement. Based on these measurements, cutting force is regulated at a constant level by feedrate control.

  • PDF

A Study on Optimization Development of Peltier Air-conditioning System (펠티어 냉난방시스템 최적화 기술에 관한 연구)

  • Park, Sanghoon;Jeong, Soojin;Park, Youngwoo;Park, Ukyung;Song, Beomjung
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

A Study on Constant Power Control of Doubly-fed Induction Generator for Wind Turbines (풍력발전을 위한 권선형 유도발전기의 정출력 제어에 관한 연구)

  • Kim, Rae-Young;Suh, In-Young;Song, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1312-1314
    • /
    • 2001
  • This paper presents a constant power controller for doubly-fed. Induction generators used in wind turbines. When the stator side of the generator is connected to the grid, the generated power depends on the rotor current. To control the rotor current based on it's average value, a cost effective SPC (Slip Power Controller) was developed and is ready for testing with an actual 660KW generator system. Experiment results are presented and discussed.

  • PDF

LED Driver by the Low Cost DSP (저가형 DSP를 이용한 LED 구동회로)

  • Song, Jae-Wook;Yoo, Jin-Wan;Park, Chong-Yeun
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.103-107
    • /
    • 2012
  • Due to improvement of the semiconductor technology, the LED replaces the conventional lighting source and LED drivers have been studied and developed. The LED is driven by the constant current control method according to its characteristics. For the constant current control method, the linear regulator and the switching regulator is used. The switching regulator is usually used to LED drivers because it has specific characteristics as the wide input dynamic range and the high efficiency. In this paper, we have described the principle and the implement of the switching regulator, using the drive IC and the low cost DSP chip. Also, both methods have been implemented and its electrical characteristics had almost same experimental results in the steady state and the transient state.

  • PDF