• Title/Summary/Keyword: Constant power

Search Result 2,845, Processing Time 0.026 seconds

A Study on the Modeling and Operation Algorithm of Independent Power System for Carbon Free (Carbon Free를 위한 도서지역용 독립전원계통의 모델링 및 운용알고리즘에 관한 연구)

  • Wang, Jong-Yong;Kim, Byung-Ki;Park, Jea-Bum;Kim, Byung-Mok;Kim, Eung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.760-768
    • /
    • 2016
  • Recently, as one of the policies for carbon free operation method of independent power system replacing diesel generator with renewable energy such as wind power and photovoltaic(PV) system has been presented. Therefore, this paper proposes an operation algorithm and modeling of independent power system by considering CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage, LC(load control) ESS for demand and supply balancing and SVC(static var compensator) for reactive power compensation. From the simulation results based on the various operation scenario, it is confirmed that proposed operation algorithm and modeling may contribute stable operation and carbon free in independent power system.

Scheme and Movement/Tension Control of Working Robot for the Installation of an Overhead Power Cable (1) (전력케이블 가설용 작업로봇의 구성과 이동/장력 혼합제어에 관한 연구(1))

  • Choi, Dong Soo;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.28-34
    • /
    • 2016
  • When a electric power cable is installed in the air for newly or exchanged working, it is necessary at all time to hold a constant tension for an overhead power cable. And also a pendanted power cable is an extreme job to have work in a high sky. For this reason, the objective of this paper developments working robot for preventing disaster that tension of cable installed automatically power cable to hold a constant. So the working robot works at all the time two tasks for mobil and tension it come into a inference between two tasks, control is difficult. Control methode needs to suppress inference of two tasks. In this paper, for installation of overhead power cable, the scheme and control methode of working robot is presented. the robot work at a same time tow tasks that have hold a constant tension of the power cable and move a constant place while unfasten a winding cable at a drum on a chassis. Working robot consist of three parts with mobile system, tension system and control part. As it is applied the feedback/feedforward control, methode of hybrid control is established to suppress that interference come into between two tasks. The simulation programs is made out using models of mobil and tension system, and a proposed controllers. In accordance with simulation, the model of each systems is discussed to make out proper. And also parameters of controllers is selected a suitable value and the driving performance of robot is evaluated.

Characterization and Performance Evaluation of Advanced Aircraft Electric Power Systems

  • Eid, Ahmad;El-Kishky, Hassan;Abdel-Salam, Mazen;El-Mohandes, Mohamed T.
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.563-571
    • /
    • 2010
  • A model of an advanced aircraft electric power system is developed and studied under variable-speed constant-frequency (VSCF) operation. The frequency of the generator's output voltage is varied from 400-Hz to 800-Hz for different loading scenarios. Power conversions are obtained using 12-pulse power converters. To reduce the harmonic contents of the generator output waveforms, two high-pass passive filters are designed and installed one at a time at the generator terminals. The performance of the two passive filters is compared according to their losses and effectiveness. The power quality characteristics of the studied VSCF aircraft electric power system are presented and the effectiveness of the proposed filter is demonstrated through compliance with the newly published aircraft electrical standards MIL-STD-704F.

Blind Algorithms with Decision Feedback based on Zero-Error Probability for Constant Modulus Errors

  • Kim, Nam-Yong;Kang, Sung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12C
    • /
    • pp.753-758
    • /
    • 2011
  • The constant modulus algorithm (CMA) widely used in blind equalization applications minimizes the averaged power of constant modulus error (CME) defined as the difference between an instant output power and a constant modulus. In this paper, a decision feedback version of the linear blind algorithm based on maximization of the zero-error probability for CME is proposed. The Gaussian kernel of the maximum zero-error criterion is analyzed to have the property to cut out excessive CMEs that may be induced from severely distorted channel characteristics. Decision feedback approach to the maximum zero-error criterion for CME is developed based on the characteristic that the Gaussian kernel suppresses the outliers and this prevents error propagation to some extent. Compared to the linear algorithm based on maximum zero-error probability for CME in the simulation of blind equalization environments, the proposed decision feedback version has superior performance enhancement particularly in cases of severe channel distortions.

Robust On-line Rotor Time Constant Estimation for Induction Machines

  • Yoo, Anno
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.1000-1007
    • /
    • 2014
  • This paper proposes an on-line rotor time constant estimation strategy for indirect field oriented induction machines. The performance of the indirect field oriented control is dependent especially on the rotor time constant whose value varies according to the temperature. The proposed method calculates the difference between the nominal rotor time constant and the real value from the d- and q-axis integration terms of a proportional integral (PI) current regulator and the demanded voltages of the induction machine to regulate the current in the steady state. Because the proposed strategy has a simple structure and is available in wide speed and torque ranges, the proposed method can be easily used in the industrial field. The effectiveness of proposed strategy is verified with simulations and a 7.5kW experimental setup.

Constant-Amplitude Multi-Code Trans-Orthogonal Modulation (정진폭 다중부호 트랜스직교변조)

  • Hong, Dae-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.493-499
    • /
    • 2011
  • To improve the bandwidth efficiency of conventional orthogonal modulation, the MCTO(Multi-Code Trans-Orthogonal) modulation, which is modified orthogonal modulation, was proposed. However, the RF(Radio Frequency) power amplifier for the MCTO modulation is too complex to reject the amplitude distortion due to the non-constant amplitude property of the MCTO. Therefore, in this paper, CAMCTO(constant-amplitude multi-code trans-orthogonal) modulation is proposed by using the constant-amplitude encoding algorithm for multi-code signal. Additionally, the performance of the proposed CAMCTO modulation is compared with those of the orthogonal modulation and the MCTO modulation by using the computer simulation. The computer simulations show that the bandwidth efficiency of the proposed CAMCTO modulation is better than that of the conventional orthogonal modulation.

Optimal Criterion for the Scale-Up Production of Schizophyllan in the Stirred Tank Reactor

  • KWAK, JUNG-KI;KOO, JAE-GUEN;PARK, SUNG-WOO;CHO, MAN-GI;KANG, BYEONG-CHUL;RAINER BUCHHOLZ;PETER GOETZ
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Optimal criterion for the scale-up production of schizophyllan, a fungal polysaccharide secreted by Schizophyllum commune, was investigated. For the production of the polysaccharide in a 150-l bioreactor, the culture conditions optimized in a 15-l bioreactor were applied to a 150-l bioreactor with scale-up process, by changing impeller speed and airflow rate. The optimized impeller speed in the 15-l bioreactor was 50 rpm in a technical medium based on barley. For establishment of the scale-up process, 3 kinds of criteria were used while the gas throughput number was kept constant, as follows; constant volume-related power input, constant tip speed of stirrer, and constant Reynolds number. In the 150-l bioreactor, the highest values for the maximum specific growth rate (1.17/day) and productivity (0.63 g/L${\cdot}$day) were achieved in the culture condition from constant volumerelated power input criterion.

Optimal Power Distribution for an Electric Vehicle with Front In-line Rear In-wheel Motors (전륜 인라인 후륜 인휠 모터 적용 전기자동차의 최적 동력 분배)

  • Kim, Jeongmin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.76-82
    • /
    • 2014
  • In this paper, an optimal power distribution algorithm is proposed for the small electric vehicle with front in-line and rear in-wheel motors. First, it is assumed that the vehicle driving torque and velocity are given conditions. And, an optimal problem is defined that finding the front and rear motor torques which minimizes the battery power. From the above optimization problem, the optimized front-rear motor torque distribution map is obtained. And, the vehicle simulations are performed to verify the performance of the optimal power distribution algorithm which is proposed in this study. The simulations are performed based on the federal urban driving schedule for two cases which are constant ratio power distribution, and optimal power distribution. From the simulation results, it is found that the optimal power distribution shows the 6.3% smaller battery energy consumption than the constant ratio power distribution.

An experimental examination of SLIM characteristics under the condition of V/F constant (V/F 일정 운전시의 편측식 선형유도전동기 특성의 실험적 고찰)

  • Cho, Yun-Hyun;Shin, Pan-Seok;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.131-134
    • /
    • 1991
  • In order to determine an operating pattern of SLIM in an experimental MAGLEV vehicle, operating characteristics of SLIM are obtained using a disk type test facility. The test results are compared with the pre-estimated values. It is found that a closed loop control is required for operating at a constant slip-frequency condition which makes the normal force minimum.

  • PDF

An Adaptive Radial Basis Function Network algorithm for nonlinear channel equalization

  • Kim Nam yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3C
    • /
    • pp.141-146
    • /
    • 2005
  • The authors investigate the convergence speed problem of nonlinear adaptive equalization. Convergence constraints and time constant of radial basis function network using stochastic gradient (RBF-SG) algorithm is analyzed and a method of making time constant independent of hidden-node output power by using sample-by-sample node output power estimation is derived. The method for estimating the node power is to use a single-pole low-pass filter. It is shown by simulation that the proposed algorithm gives faster convergence and lower minimum MSE than the RBF-SG algorithm.