• Title/Summary/Keyword: Constant load

Search Result 1,723, Processing Time 0.036 seconds

Sensorless Speed Control for Brushless DC Motor using Digital IP Controller (디지털 IP 제어기를 이용한 브러시리스 직류 전동기의 센서리스 속도제어)

  • Kim Jong-Sun;Park Hyong-Joon;Jang Jae-Hoon;Yoo Ji-Yoon;Seo Sam-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.289-293
    • /
    • 2004
  • The sensorless speed control technique for BLDCM using digital IP control is proposed in this paper for advanced speed characteristic which is robust for loads. The sensorless drive of BLDCM using terminal voltages is affected by load or speed because it uses analog filters to estimate the rotor position. For this reason, the robust speed controller with the accurate rotor position estimator is needed for sensorless control which is robust to load and insensitive to motor parameters. The constant speeds robust to load variation and the stable sensorless control of BLDCM robust to the increase or decrease of speed with constant load are implemented using digital IP control in this paper. The validity to these is established with experimentation.

  • PDF

Electric-Field-Induced Strain Properties of Multi Layer Ceramic Actuator Using PMN-PZ-PT Ceramics (PMN-PZ-PT 세라믹스를 이용한 적층형 액츄에이터의 변위특성)

  • Ha, Mun-Su;Jeong, Soon-Jong;Koh, Jung-Hyuk;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.620-623
    • /
    • 2003
  • Non-linear behaviors of multilayer piezoelectric ceramic actuator (MCA) were investigated under electrical and mechanical stress. DC 100 V bias was applied to the MCA to obtain displacement. Laser vibrometer, which using Doppler effect, was employed to characterize displacement caused by $d_{33}$ mode of MCA. To understand this non-linear behavior of MCA, displacement was measured and compared under different load states. By increasing load, electric field-induced strain and piezoelectric constant($d_{33}$) of MCA was decreased. We attribute this phenomenon to the domain wall motion and depoling of MCA under heavy load.

  • PDF

Speed Control of an Overcentered Variable-Displacement Hydraulic Motor on a Constant Pressure Network (일정 압력원에 연결된 가변유압모터의 속도제어)

  • 김철수;이정오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.272-276
    • /
    • 1996
  • This study deals with the speed control of an overcentered variable-displacement hydraulic motor on a constant pressure network, which is noted for its high system efficiency fast dynamic response and energy recovery capability. The speed control characteristics of the conventional cascade PI controller are largely affected by load-torque disturbances. To obtain robust speed control despite torque disturbances, the load torque is estimated by an observer based on a mathematical model and compensated for by a feedforward loop. It is shown by experiment that robust speed control may be obtained with the proposed controller. The experimental data agree fairly well with the theoretical analysis.

  • PDF

Behavior of reinforced lightweight aggregate concrete hollow-core slabs

  • Al-Azzawi, Adel A.;Al-Aziz, Basma M. Abdul
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.117-126
    • /
    • 2018
  • This research investigate the behavior of reinforced normal and lightweight aggregate concrete hollow core slabs with different core shapes, shear span to effective depth (a/d). The experimental work includes testing seven reinforced concrete slabs under two vertical line loads. The dimensions of slab specimens were (1.1 m) length, (0.6 m) width and (0.12 m) thickness. The maximum reduction in weight due to aggregate type was (19.28%) and due to cross section (square and circular) cores was (17.37 and 13.64%) respectively. The test results showed that the decrease of shear span to effective depth ratio from 2.9 to 1.9 for lightweight aggregate solid slab cause an increase in ultimate load by (29.06%) and increase in the deflection value at ultimate load or the ultimate deflection by (17.79%). The use of lightweight aggregate concrete in casting solid slabs give a reduction in weight by (19.28%) and in the first cracking and ultimate loads by (16.37%) and (5%) respectively for constant (a/d=2.9).The use of lightweight aggregate concrete in casting hollow circular core slabs with constant (a/d=2.9) (reduction in weight 32.92%) decrease the cracking and ultimate loads by (12%) and (5.18%) respectively with respect to the solid slab. These slab specimens were analyzed numerically by using the finite element computer program ANSYS. Good agreements in terms of behavior, cracking load (load at first visible crack) and ultimate load (maximum value of testing load) was obtained between finite element analysis and experimental test results.

Static Load Analysis of Twin-screw Kneaders

  • Wei, Jing;Zhang, Guang-Hui;Zhang, Qi;Kim, Jun-Seong;Lyu, Sung-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.59-63
    • /
    • 2008
  • A static load analysis of twin-screw kneaders is required not only for the dynamic analysis, but also because it is the basis of the stiffness and strength calculations that are essential for the design of bearings. In this paper, the static loads of twin-screw kneaders are analyzed, and a mathematical model of the force and torque moments is presented using a numerical integration method based on differential geometry theory. The calculations of the force and torque moments of the twin-screw kneader are given. The results show that the $M_x$ and $M_y$ components of the fluid resistance torque of the rotors change periodically in each rotation cycle, but the $M_z$ component remains constant. The axis forces $F_z$ in the female and male rotors are also constant. The static load calculated by the proposed method tends to be conservative compared to traditional methods. The proposed method not only meets the static load analysis requirements for twin-screw kneaders, but can also be used as a static load analysis method for screw pumps and screw compressors.

Development of Hybrid AVR for Alternator (교류 발전기용 하이브리드 자동 전압 조정기 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.182-188
    • /
    • 2015
  • An analog AVR has an advantage of short time constant, time to revert again from the abnormal state to a stable one depending on the voltage fluctuations of the load. But the Analog AVR has a disadvantage of large voltage variation according to the load fluctuation. Voltage regulation for digital AVR is very stable, but the time constant is very long compared to that of an analog AVR. Therefore, it indicates that the digital AVR shows unstable output performance in a very large load variations. In this paper, a mixed form of an analog AVR and a digital AVR is proposed. An implemented hybrid AVR has fast time constant and stable voltage regulation capability. Hybrid AVR voltage variations in the load is stable within 1[%] and the voltage stability is also improved. It also showed fast time constant to the level of the analog AVR. Thus hybrid AVR developed in this paper can be used as a power supply for a variety of uses in industry.

Voltage Gain and Efficiency Analysis of Piezoelectric Transformer using Lumped constant Equivalent Circuit (집중 등가회로를 사용한 압전 변압기의 승합비 및 효율 해석)

  • 류주현;이용우;윤광희;정희승;정영호;박창엽
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.849-854
    • /
    • 1998
  • The load characteristics on the voltage gain and efficiency were analyzed using a lumped constant equivalent circuit of the piezoelectric transformer. These analytical results were confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency is higher than experimental ones.

  • PDF

Voltage Gain and Efficiency Ana1ysis of Piezoelectric Transformer using Lumped Constant Equivalent Circuit (Rosen형 압전 트랜스포머의 집중등가회로를 사용한 승압비 및 효율 해석)

  • 김만성;류주현;정회승;박창엽;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.183-189
    • /
    • 1998
  • In this paper, The load characteristics on the voltage gain and efficiency were analyzed sing an lumped constant equivalent circuit of the piezoelectric transformer. These analytical results are confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency had higher values than experimental ones.

  • PDF

Dynamic Snapping and Frequency Characteristics of 3-Free-Nodes Spatial Truss Under the Periodic Loads (주기 하중을 받는 3-자유절점 공간 트러스의 동적 불안정 현상과 주파수 특성)

  • Shon, Sudeok;Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.149-158
    • /
    • 2020
  • The governing equation for a dome-type shallow spatial truss subjected to a transverse load is expressed in the form of the Duffing equation, and it can be derived by considering geometrical non-linearity. When this model under constant load exceeds the critical level, unstable behavior is appeared. This phenomenon changes sensitively as the number of free-nodes increases or depends on the imperfection of the system. When the load is a periodic function, more complex behavior and low critical levels can be expected. Thus, the dynamic unstable behavior and the change in the critical point of the 3-free-nodes space truss system were analyzed in this work. The 4-th order Runge-Kutta method was used in the system analysis, while the change in the frequency domain was analyzed through FFT. The sinusoidal wave and the beating wave were utilized as the periodic load function. This unstable situation was observed by the case when all nodes had same load vector as well as by the case that the load vector had slight difference. The results showed the critical buckling level of the periodic load was lower than that of the constant load. The value is greatly influenced by the period of the load, while a lower critical point was observed when it was closer to the natural frequency in the case of a linear system. The beating wave, which is attributed to the interference of the two frequencies, exhibits slightly more behavior than the sinusoidal wave. And the changing of critical level could be observed even with slight changes in the load vector.

Investigation on Characteristics of the Baseline Controller for NREL 5 MW Wind Turbine (NREL 5 MW 풍력발전기의 기본 제어기에 대한 특성 고찰)

  • Kim, Jong-Hwa;Moon, Seok-Jun;Shin, Yun-Ho;Won, Moon-Chul
    • Journal of Wind Energy
    • /
    • v.3 no.2
    • /
    • pp.34-41
    • /
    • 2012
  • The paper is focusing on investigating the control characteristics of the baseline controller of 5 MW wind turbine provided by NREL(National Renewable Energy Laboratory). The baseline controller consist of two control logics, a maximum power tracking control below the rated wind speed and a constant power control above the rated wind speed. In the low wind speed, the mean generator power for changing the turbulent intensity and the optimal constant is studied through numerical simulations using FAST program. On the other hand, the constant power control logic and the constant control logic are compared in the high wind speed. It is confirmed that optimal constant is closely related to the turbulent intensity in low wind speed region and the constant torque control has better performance than the constant power control with respect to mechanical load in high wind speed region.