직류전위차법을 이용한 랜덤하중하의 피로균열 진전율에 대한 신뢰성 공학적 연구 (Reliability Engineering Approach to Fatigue Crack Growth Rate Under Random Loading Using DC Eletrical Potential Method)

  • 배성인
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.473-480
    • /
    • 1996
  • Automatic fatigue crack length measuring system using DC electrical potential method and the system control program for automatic fatigue testing under random load condition were made in this study. And using these system and control program, fatigue tests were executed under constant and random load condition. As the result, the propagation of crack in random loading can be represented Paris equaiton and log normal probability function. But constant and random load test show different crack propagation properties.

디지털 IP 제어기를 이용한 브러시리스 직류 전동기의 센서리스 속도제어 (Sensorless Speed Control for Brushless DC Motor using Digital IP Controller)

  • 김종선;박형준;장재훈;유지윤;서삼준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.289-293
    • /
    • 2004
  • The sensorless speed control technique for BLDCM using digital IP control is proposed in this paper for advanced speed characteristic which is robust for loads. The sensorless drive of BLDCM using terminal voltages is affected by load or speed because it uses analog filters to estimate the rotor position. For this reason, the robust speed controller with the accurate rotor position estimator is needed for sensorless control which is robust to load and insensitive to motor parameters. The constant speeds robust to load variation and the stable sensorless control of BLDCM robust to the increase or decrease of speed with constant load are implemented using digital IP control in this paper. The validity to these is established with experimentation.

  • PDF

PMN-PZ-PT 세라믹스를 이용한 적층형 액츄에이터의 변위특성 (Electric-Field-Induced Strain Properties of Multi Layer Ceramic Actuator Using PMN-PZ-PT Ceramics)

  • 하문수;정순종;고중혁;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.620-623
    • /
    • 2003
  • Non-linear behaviors of multilayer piezoelectric ceramic actuator (MCA) were investigated under electrical and mechanical stress. DC 100 V bias was applied to the MCA to obtain displacement. Laser vibrometer, which using Doppler effect, was employed to characterize displacement caused by $d_{33}$ mode of MCA. To understand this non-linear behavior of MCA, displacement was measured and compared under different load states. By increasing load, electric field-induced strain and piezoelectric constant($d_{33}$) of MCA was decreased. We attribute this phenomenon to the domain wall motion and depoling of MCA under heavy load.

  • PDF

일정 압력원에 연결된 가변유압모터의 속도제어 (Speed Control of an Overcentered Variable-Displacement Hydraulic Motor on a Constant Pressure Network)

  • 김철수;이정오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.272-276
    • /
    • 1996
  • This study deals with the speed control of an overcentered variable-displacement hydraulic motor on a constant pressure network, which is noted for its high system efficiency fast dynamic response and energy recovery capability. The speed control characteristics of the conventional cascade PI controller are largely affected by load-torque disturbances. To obtain robust speed control despite torque disturbances, the load torque is estimated by an observer based on a mathematical model and compensated for by a feedforward loop. It is shown by experiment that robust speed control may be obtained with the proposed controller. The experimental data agree fairly well with the theoretical analysis.

  • PDF

Behavior of reinforced lightweight aggregate concrete hollow-core slabs

  • Al-Azzawi, Adel A.;Al-Aziz, Basma M. Abdul
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.117-126
    • /
    • 2018
  • This research investigate the behavior of reinforced normal and lightweight aggregate concrete hollow core slabs with different core shapes, shear span to effective depth (a/d). The experimental work includes testing seven reinforced concrete slabs under two vertical line loads. The dimensions of slab specimens were (1.1 m) length, (0.6 m) width and (0.12 m) thickness. The maximum reduction in weight due to aggregate type was (19.28%) and due to cross section (square and circular) cores was (17.37 and 13.64%) respectively. The test results showed that the decrease of shear span to effective depth ratio from 2.9 to 1.9 for lightweight aggregate solid slab cause an increase in ultimate load by (29.06%) and increase in the deflection value at ultimate load or the ultimate deflection by (17.79%). The use of lightweight aggregate concrete in casting solid slabs give a reduction in weight by (19.28%) and in the first cracking and ultimate loads by (16.37%) and (5%) respectively for constant (a/d=2.9).The use of lightweight aggregate concrete in casting hollow circular core slabs with constant (a/d=2.9) (reduction in weight 32.92%) decrease the cracking and ultimate loads by (12%) and (5.18%) respectively with respect to the solid slab. These slab specimens were analyzed numerically by using the finite element computer program ANSYS. Good agreements in terms of behavior, cracking load (load at first visible crack) and ultimate load (maximum value of testing load) was obtained between finite element analysis and experimental test results.

Static Load Analysis of Twin-screw Kneaders

  • Wei, Jing;Zhang, Guang-Hui;Zhang, Qi;Kim, Jun-Seong;Lyu, Sung-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.59-63
    • /
    • 2008
  • A static load analysis of twin-screw kneaders is required not only for the dynamic analysis, but also because it is the basis of the stiffness and strength calculations that are essential for the design of bearings. In this paper, the static loads of twin-screw kneaders are analyzed, and a mathematical model of the force and torque moments is presented using a numerical integration method based on differential geometry theory. The calculations of the force and torque moments of the twin-screw kneader are given. The results show that the $M_x$ and $M_y$ components of the fluid resistance torque of the rotors change periodically in each rotation cycle, but the $M_z$ component remains constant. The axis forces $F_z$ in the female and male rotors are also constant. The static load calculated by the proposed method tends to be conservative compared to traditional methods. The proposed method not only meets the static load analysis requirements for twin-screw kneaders, but can also be used as a static load analysis method for screw pumps and screw compressors.

교류 발전기용 하이브리드 자동 전압 조정기 개발 (Development of Hybrid AVR for Alternator)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제16권4호
    • /
    • pp.182-188
    • /
    • 2015
  • 아날로그 AVR은 부하의 변동에 따라 전압이 비정상상태가 되었다가 다시 정상상태로 돌아가는데 걸리는 시간이 빠른 장점이 있다. 하지만 아날로그 AVR은 부하 변동에 따른 전압변동이 크다는 문제가 있다. 디지털 AVR의 전압변동률은 매우 안정적이지만, 불안정상태에서 안정한 정상상태로 회복하는데 걸리는 시간인 시정수가 아날로그 AVR에 비해 매우 길다. 따라서 부하변동이 매우 큰 상황에서 불안정한 출력성능을 나타낸다. 본 논문에서는 두 AVR의 혼합된 형태를 가지며 빠른 시정수와 안정된 전압조정 능력을 갖는 하이브리드 AVR을 제안한다. 개발된 하이브리드 AVR의 경우 부하에 따른 전압 변동이 1[%] 이내로 안정적이며, 전압 안정률도 개선되었다. 또한 아날로그 AVR 수준의 빠른 시정수를 나타내었다. 따라서 본 연구를 통해서 개발된 하이브리드 AVR은 산업현장에서 다양한 용도의 전원공급장치로 활용될 수 있다.

집중 등가회로를 사용한 압전 변압기의 승합비 및 효율 해석 (Voltage Gain and Efficiency Analysis of Piezoelectric Transformer using Lumped constant Equivalent Circuit)

  • 류주현;이용우;윤광희;정희승;정영호;박창엽
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.849-854
    • /
    • 1998
  • The load characteristics on the voltage gain and efficiency were analyzed using a lumped constant equivalent circuit of the piezoelectric transformer. These analytical results were confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency is higher than experimental ones.

  • PDF

Rosen형 압전 트랜스포머의 집중등가회로를 사용한 승압비 및 효율 해석 (Voltage Gain and Efficiency Ana1ysis of Piezoelectric Transformer using Lumped Constant Equivalent Circuit)

  • 김만성;류주현;정회승;박창엽;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.183-189
    • /
    • 1998
  • In this paper, The load characteristics on the voltage gain and efficiency were analyzed sing an lumped constant equivalent circuit of the piezoelectric transformer. These analytical results are confirmed by experiments. Theoretical values of voltage gain were nearly constant with experimental ones. However, It was shown that theoretical values of efficiency had higher values than experimental ones.

  • PDF

주기 하중을 받는 3-자유절점 공간 트러스의 동적 불안정 현상과 주파수 특성 (Dynamic Snapping and Frequency Characteristics of 3-Free-Nodes Spatial Truss Under the Periodic Loads)

  • 손수덕;황경주
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.149-158
    • /
    • 2020
  • The governing equation for a dome-type shallow spatial truss subjected to a transverse load is expressed in the form of the Duffing equation, and it can be derived by considering geometrical non-linearity. When this model under constant load exceeds the critical level, unstable behavior is appeared. This phenomenon changes sensitively as the number of free-nodes increases or depends on the imperfection of the system. When the load is a periodic function, more complex behavior and low critical levels can be expected. Thus, the dynamic unstable behavior and the change in the critical point of the 3-free-nodes space truss system were analyzed in this work. The 4-th order Runge-Kutta method was used in the system analysis, while the change in the frequency domain was analyzed through FFT. The sinusoidal wave and the beating wave were utilized as the periodic load function. This unstable situation was observed by the case when all nodes had same load vector as well as by the case that the load vector had slight difference. The results showed the critical buckling level of the periodic load was lower than that of the constant load. The value is greatly influenced by the period of the load, while a lower critical point was observed when it was closer to the natural frequency in the case of a linear system. The beating wave, which is attributed to the interference of the two frequencies, exhibits slightly more behavior than the sinusoidal wave. And the changing of critical level could be observed even with slight changes in the load vector.