• 제목/요약/키워드: Constant current test

검색결과 273건 처리시간 0.022초

Surface Characteristics of Anodized Ti-3wt%, 20wt%, and 40wt%Nb Alloys

  • Ko, Y.M.;Choe, H.C.;Jang, S.H.;Kim, T.H.
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.143-147
    • /
    • 2009
  • In biomedical implants and dental fields, titanium has been widely utilized for excellent corrosion resistance and biocompatibility. However, Ti and its alloys are nonbioactive after being implanted in bone. In this study, for the purpose of improvement in biocompatibility the anodic $TiO_2$ layer on Ti-xNb alloys were fabricated by electrochemical method in phosphate solution, and the effect of Nb content on the pore size, the morphology and crystallinity of Ti oxide layer formed by the anodic oxidation method was investigated. The Ti containing Nb up to 3 wt%, 20 wt% and 40 wt% were melted by using a vacuum furnace. The sample were cut, polished, and homogenized for 24 hr at $1050^{\circ}C$ for surface roughness test and anodizing. Titanium anodic layer was formed on the specimen surface in an electrolytic solution of 1 M phosphoric acid at constant current densities ($30mA/cm^2$) by anodizing method. Microstructural morphology, crystallinity, composition, and surface roughness of oxide layer were observed by FE-SEM, XRD, EDS, and roughness tester, respectively. The structure of alloy was changed from $\alpha$-phase to $\beta$-phase with increase of Nb content. From XRD results, the structure of $TiO_2$ formed on the Ti-xNb surface was anatase, and no peaks of $Nb_2O_5$ or other Nb oxide were detected suggesting that Nb atoms are dispersed in $TiO_2$-based solid solution. Surface roughness test and SEM results, pore size formed on surface and surface roughness decreased as Nb content increased. From the line analysis results, intensity of Ti peak was high in the center of pore, whereas, intensity of O peak was high in the outside of pore center.

다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성 (Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva)

  • 김태한;박근형;손미경;김원기;장승현;최한철
    • 한국표면공학회지
    • /
    • 제41권5호
    • /
    • pp.226-231
    • /
    • 2008
  • Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |$E_{pit}\;-\;E_{corr}$| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

촉매성 산화물 전극 (DSA, Dimensionally Stable Anode)의 가속수명 테스트 방법과 장치에 관한 기초 연구 (A Basic Study on Accelerated Life Test Method and Device of DSA (Dimensionally Stable Anode) Electrode)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.467-475
    • /
    • 2018
  • The lifetime of the electrode is one of the most important factors on the stability of the electrode. Since the lifetime of the DSA (Dimensionally stable anode) electrode is long, an accelerated lifetime test is required to reduce the test time. Beacuse there is no basis or standard method for accelerated lifetime testing, many researchers use different methods. Therefore, there is a need for basis and methods for accelerated lifetime testing that other researchers can follow. We designed a reactor system for accelerated lifetime testing and planned specific methods. Reactor system was circulating batch reactor. Reactor volume and cooling water tank were 12.5 L and 100 L, respectively. Electrode size was $2cm{\times}3cm$ (real electrolysis area, $5cm^2$). In order to maintain the harsh conditions, accelerated lifetime test was carried out in a high current density ($0.6A/cm^2$) and low electrolyte concentration (NaCl, 0.068 mol/L). Maintaining a constant temperature was an important operation parameter for exact accelerated lifetime test. As the accelerated lifetime test progressed, the active component of electrode surface was consumed and desorption occurred. At the point of 5 V rise, corrosion of the surface of the base material(titanium) also started.

디지털 DC-ARC 용접기의 개발 (DEVELOPMENT OF DIGITAL DC-ARC WELDING MACHINE)

  • 박바다;;김상봉
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.71-72
    • /
    • 2006
  • This paper introduces the results of the development of a new mobile Digital DC-arc Welding Machine (DDWM). A simple PI controller is applied to the DDWM to control the output welding current tracking the constant setting current. Furthermore, a hot-start function, an anti-stuck function, a standby mode and an intelligential circuit breaker (ICB) are included in the DDWM. The DDWM increases welding quality and saves more power energy than a conventional welding machine. Because the DDWM is changed from ready mode into the standby mode automatically after 2 minutes interval from this unload start. Then the DDWM is changed into ready mode automatically since it is reused to weld. Mover, the DDWM increases welding qualify, productivity and reduces costs of welding. So, the DDWM can have a great of contribution to the mobile welding industries. The effectiveness of the DDWM was proven by the experimental results and durable test.

  • PDF

전차선로 시스템의 축약 등가 선로정수에 관한 연구 (A Reduced Equivalent Line Constant of the Catenary System)

  • 이한민;오광해;이장무;박현준;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.421-431
    • /
    • 2004
  • Line constants are composed by impedances and susceptances. A paper which was published estimated only impedances of line constants. Therefore, this paper estimates susceptances as well as impedances of equivalent five-conductors model using the reduced equivalent method. In order to verify estimated line constants, we measured line constants of real railway system. And we compared calculated results with measured data on 60Hz∼3000Hz. For the other verification, the calculation results from the proposed model and the measurement data from the test are compared focused on the amplification of harmonic current in the paper.

병행 2회선 송전선로의 개선된 거리계전기법 (Advanced Distance Relaying of on a Double Circuit Transmission Line)

  • 박철원
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

유도 전도기용 순시전류 추종형 PWM 인버터에 관한 연구 (A Strategy on Adaptive Current PWM Inverter for Induction Motor)

  • 박철우;박성준;권순재;김광태
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권2호
    • /
    • pp.56-61
    • /
    • 1992
  • 유도 전동기의 일정자속 벡터제어에서 유도전동기의 속도를 별도의 속도검출장치가 없이, 전동기의 속도를 1차측 전압과 전류 및 전동기정수에 의하여 추정하는 방법을 제시하고 전류추종형 PWM인 버터에 의하여 구동 시스템을 구성하였다. 모든 연산 및 제어회로를 마이크로프로세서에 의하여 보다 간단하게 실현시켜 유도전동기의 가변속 구동특성을 컴퓨터 시뮬레이션과 실험에 의하여 조사하였다. 속도검출장치를 이용한 경우와 연산회로에 의하여 계산된 경우의 입력 전류파형상의 차이를 조사한 결과 미소한 리플성분을 제외하고는 잘 일치하였으며, 기동 및 가감속시의 속도추종특성도 시뮬레이션의 결과와 함게 양호하게 얻어졌다.

  • PDF

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

지속적인 직류자극이 토끼 비골 골절의 신생골 형성에 미치는 영향 (The Effects of Constant Direct Current on the New Bone Formation of Fractured Fibula in Rabbits)

  • 정형국;김진상;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.95-107
    • /
    • 1994
  • This study was performed to identify the effect of constant direct current and to give us methods which can be applied easily in clinic. Six rabbits was used at this experiment. After each animal was fractured at left fibula, divided into experimental group(n=3) and central group(n=3). Experiment duration of electrical stimulation on experimental rabbits was 35 days. Direct current from fifteen microampere to twenty microampere was passed continously through the placed electrode between fracture area and thigh. Negative electrode was placed at fracture area and positive at thigh. Roentgenography was used to observe bone-healing progression wet three times-at 15days, 25days and 35days after electrical stimulation. The results obtained are as followings: 1. Both experimental group and control group do not obtain callus formation on the first roentgenography(15 days after ES). 2. On the second roentgenography(25 days after ES), experimental group achieves above $70\%$ on fracture-healing, but control group achieves about $20-30\%$ on fracture healing. 3. On the third roentgenegraphy(35 nays after ES), experimental group achieves above $85-95\%$ on fracture healing and control group achieves about $60-70\%$ of bone union. Thus, statistically significance(independent t-test) was occured ie the second and third roentgenography between experimental group and control group.

  • PDF