• 제목/요약/키워드: Constant Temperature Control

검색결과 447건 처리시간 0.03초

An experimental research on temperature accuracy in the refrigerator system with a variable speed compressor

  • Jung, Young-Seok;Hong, Boo-Pyo;Bakhtiar, Agung;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.264-269
    • /
    • 2011
  • A precision of temperature control in the manufacturing process would be an important factor and become the main key to control production quality. Mostly manufacture machinery used oil as a coolant in their system so an accurate oil temperature control system become an absolute need in industrial field. This paper presents a experiment research to control the oil temperature constant at target point, in this experiment is $35^{\circ}C$ by using an inverter attached in compressor to varying the compressor speed. This control has been completed and tested through an experiment with different heat load of 4kW, 6kW, 7kW, 8kW and 10kW given under temperature constant room conditioned as $25^{\circ}C$. The results had shown the temperature deviation in the refrigerator has around $0.2^{\circ}C$ and the COP is 2.5 gained at 8kW and 10kW.

  • PDF

Measuring System for Evaluating Sensing Reliability of Infrared Temperature Sensors

  • 박준혁;이민철;부광석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.169-173
    • /
    • 1997
  • In this paper, auto measuring system for evaluating sensing reliability of infrared temperature sensors is developed. A developed system is composed of temperature controller, measuring sysytem and operating S/W. A constant temperature control of a chamber is accomplished by multi-heater using PI control. It is shown that the control resulte of temperature are well followed to the desired temperature value. The developed untegrated measuring system will increase reliability and productivity of products.

온도 및 전류의 과도응답 제어가 가능한 SOA Driver에 관한 연구 (A Study on SOA Driver with Capability to Control Current and Temperature Transient Response)

  • 엄진섭
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In this paper, SOA Current and Temperature Driver which consisted of LabVIEW programming part capable of current and temperature transient response pattern design, DAQ module for analog voltage in&out, and voltage to current converting chips has realized. The output current(possible to 3A) from the Driver to SOA was clearly constant without ripple and also showed no variance until 1mA unit for a long time operation. The temperature of TEC took several seconds to reach a set temperature, and were maintained stably within ${\pm}^0.1{\circ}C$ for several hours. The proposed Driver can replace the previous high cost SOA Drivers for wavelength swept lasers fully and provides the convenience of transient response design capability for current and temperature.

정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구 (A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself)

  • 박종일;전광민;한재원;박철웅
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

메탄올 혼합 연료의 기화율 변화에 따른 연소특성에 관한 실험적 연구 (A Study on the Combustion Characteristics according to Evaporation rate of Methanol - Blended Fuel)

  • 조행묵
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.24-34
    • /
    • 1997
  • This paper describes the investigation of combustion characteristics of gasoline-methanol blend in constant volume combustion chamber. A constant volume combustion chamber was used to elucidate a basic combustion characteristics and the premixer was installed to control temperature and equivalence ratio. And the maximum pressure, combustion duration and flame propagation according to the evaporation rate were measured to determine the optimal temperature range for evaporating a blend fuel. These experimental results indicate that the combustion characteristics such as combustion chamber pressure and combustion were deteriorated by decreasing surrounding temperature of fuel. These experimental results indicate that the combustion characteristics such as combustion chamber pressure and combustion were deter orated by decreasing surrounding temperature of fuel injected. It was also found that the overall gasification process for methanol blend fuel was influenced by a combustion chamber temperature rather than a premixer temperature.

  • PDF

저온영역에서 단열용기를 이용한 연료전지 모의 실험 (Simulation Experiment of PEMFC Using Insulation Vessel at Low Temperature Region)

  • 조인수;권오정;김유;현덕수;박창권;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.403-409
    • /
    • 2008
  • Polymer electrolyte membrane fuel cell (PEMFC) is very interesting power source due to high power density, simple construction and operation at low temperature. But it has problems such as high cost, improvement of performance, effect of temperature and initial start at low temperature. These problems can be approached to be solved by using experiment and mathematical method which are general principles for analysis and optimization of control system for heat and hydrogen detecting management. In this paper, insulation vessel and control system for stable operation of fuel cell at low temperature were developed for experiment. The constant temperature capability and the heating time at sub-zero temperatures with insulation control system were studied by using a heating bar of 60W class. PEMFC stack which was made by 4 cells with $50\;mc^2$ active area in each cell is a thermal source. Times which take to reach constant temperature by the state of insulation vacuum were measured at variable environment temperatures. The test was performed at two conditions: heating mode and cooling mode. Constant temperature capability was better at lower environment temperature and vacuum pressure. The results of this experiment could be used as basis data about stable operation of fuel cell stack in low temperature zone.

단상 인버터 열처리 시스템의 제어기법 (Control Methods of the Single-Phase Inverter Heat Treatment System)

  • 양시경;후인 안 뚜언;전태원;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.280-281
    • /
    • 2018
  • The methods for adjusting the output voltage as well as the heater temperature of a single-phase inverter for the heat treatment are proposed. The output voltage of the single-phase inverter is limited to 60 V for safety. The time constant of heater temperature is much higher than that of the output voltage. The stability may be deteriorated due to such large time constant difference. In order to ensure the stability, a hysteresis on/off control method for the heater temperature control is used. The performances for the proposed methods are verified with the experiments.

  • PDF

유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발 (Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors)

  • 홍성호
    • Tribology and Lubricants
    • /
    • 제37권2호
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.

Observation of Moisture Content in Wood at Non-Steady State

  • Hwang, Sung-Wook;Lee, Won-Hee
    • 한국가구학회지
    • /
    • 제20권6호
    • /
    • pp.599-604
    • /
    • 2009
  • For the search of unified law of moisture movement in wood, moisture distribution of Korean red pine at non-steady state was investigated. We assume that the equilibrium moisture content (EMC) in wood depends on only temperature and relative humidity, it can be control in temperature and humidity chamber. If temperature is constant and humidity or vapor pressure is changed with sin curve shape at adequate cycles, EMC in chamber can be changed as well with sin-curve shape. The setup condition of a non-steady state in humidity control chambers is a constant temperature at $20^{\circ}C$ and 15+10 sin ${\omega}t$ percent EMC. It can be found that the distribution of moisture in the specimen with varying relative humidity are illustrated various types. Moisture in wood is complicated and vibrates with the moisture sorption process. Considering a unified law of moisture movement in wood, it is considered that the most important fact is to search the method of precise diffusion & transfer coefficients.

  • PDF

Decoupled Plasma Nitridation 공정 적용을 통한 Negative Bias Temperature Instability 특성 개선 (Improvement of Negative Bias Temperature Instability by Decoupled Plasma Nitridation Process)

  • 박호우;노용한
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.883-890
    • /
    • 2005
  • In this paper, the established model of NBTI (Negative Bias Temperature Instability) mechanism was reviewed. Based on this mechanism, then, the influence of nitrogen was discussed among other processes. A constant concentration of nitrogen exists inside $SiO_2$ in order to prevent boron from diffusing and to increase dielectric constant. It was shown that NBTI improvement was achieved by controlling nitrogen profile. It was supposed that the existence of low activation energy of Si-N bonds at $Si-SiO_2$ interface attributes the improvement by making hydrogen prevent interface traps. It was also shown that improvement of NBTI can be achieved by more effective control of nitrogen profile. It was supposed that the maximum control of nitrogen profile can be achieved by DPN (Decoupled Plasma Nitridation) process.