• 제목/요약/키워드: Connection Development

검색결과 1,914건 처리시간 0.027초

GENERALIZED AFFINE DEVELOPMENTS

  • Park, Joon-Sik
    • 충청수학회지
    • /
    • 제28권1호
    • /
    • pp.65-72
    • /
    • 2015
  • The (affine) development of a smooth curve in a smooth manifold M with respect to an arbitrarily given affine connection in the bundle of affine frames over M is well known (cf. S.Kobayashi and K.Nomizu, Foundations of Differential Geometry, Vol.1). In this paper, we get the generalized affine development of a smooth curve $x_t$ ($t{\in}[0,1]$) in M into the affine tangent space at $x_0$ (${\in}M$) with respect to a given generalized affine connection in the bundle of affine frames over M.

플라스틱 온실의 강관 이음부 휨성능 분석 (Evaluation of Steel-Pipe Connections in Plastic Greenhouse Using Bending Test)

  • 최만권;류희룡;조명환;유인호
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.391-399
    • /
    • 2018
  • 본 연구에서는 현장에서 사용되는 온실 강관의 이음 방법에 대해 휨성능을 평가하고 그 결과를 바탕으로 가장 휨성능이 우수한 이음 방법을 알아보았다. 실험 결과, 모든 실험체는 이음이 없는 실험체 보다 휨성능이 작았다. 그러나 모든 실험체의 최대 휨모멘트는 이음이 없는 실험체 소성모멘트의 1.07~1.3정도로 나타났다. 또한 연결방법에 따른 결과는 연결핀 보다 인발 실험체가 상대적으로 큰 휨성능을 보였다. 현장 이음 방법의 파괴 모드는 연결핀과 강관 끝부분의 응력집중에 의한 국부좌굴이 지배적이었다. 현장시공 시 강관을 절단 후 연결할 경우, 이음 없이 사용하는 것이 가장 우수한 휨성능을 발휘하지만 부득이 강관을 절단할 경우는 연결핀보다는 인발 강관에 직결나사로 고정한 이음 방법(SPJ-F)으로 시공하는 것이 유리할 것으로 판단된다.

Investigation of a new steel-concrete connection for composite bridges

  • Papastergiou, Dimitrios;Lebet, Jean-Paul
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.573-599
    • /
    • 2014
  • A new type of connection for steel-concrete composite bridges was developed by the Steel Structures Laboratory of Ecole Poytechinque $F{\acute{e}}d{\acute{e}}rale$ de Lausanne. Resistance to longitudinal shear is based on the development of shear stresses in the confined interfaces which form the connection. Confinement is provided by the reinforced concrete slab which encloses the connection and restrains the uplift (lateral separation) of the interfaces by developing normal stresses. The experimental investigation of the interfaces, under static and cyclic loading, enabled the development of the laws describing the structural behaviour of each interface. Those laws were presented by the authors in previous papers. The current paper focuses on the continuity of the research. It presents the experimental investigation on the new connection by means of push-out tests on specimens submitted to static and cyclic shear loading. Investigation revealed that the damage in the connection, due to cyclic loading, is expressed by the accumulation of a residual slip. A safe fatigue failure criterion is proposed for the connection which enabled the verification of the connection for the fatigue limit state with respect to the limit of fatigue. A numerical model is developed which takes into account the laws describing the interface behaviour and the analytical expressions for the confinement effect, the latter obtained by performing finite element analysis. This numerical model predicts the shear resistance of the connection and enables to assess its fatigue limit which is necessary for the fatigue design proposed.

CFT 선기초기둥과 슬래브 접합부 개발 (Development of Connection between CFT Prefounded Column and Slab)

  • 송지윤;임홍철;김승원;김동건;강승룡;정미라
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.129-133
    • /
    • 2008
  • For the construction of Top-Down structures, it is crucial to have a solid connection between prefounded columns and slabs. This paper presents a new construction method for the connection when using a circular Concrete Filled Tube (CFT) as a prefounded column as an alternative to currently using wide flange type columns. The development of shear studded jackets along with a shear band suitable for the circular shape of the column has been made. The details and mechanism of the connection is explained together with the results of experiments which verified the structural integrity of the connection.

  • PDF

철근콘크리트 기둥과 철골보의 접합부 개발 및 지압성능에 관한 시험적 연구 (A Study on the Development and Test on Bearing Resistance of R/C Column-Steel Girder Connection)

  • 최광호;이세웅;김재순;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.515-520
    • /
    • 1997
  • This research is aimed at the development of the composite beam-column connection system by which the steel beam can be connected to the R/C column with smooth stress transfer. As the first step of the structural performance tests of the system, bearing resistance test has been carried out for actual size specimen. From the test, the connection system has been proved to take good bonding and stress transfer to the surrounding concrete with negligible relative displacements.

  • PDF

채널과 커플러를 사용한 모듈식 구조체 우각부 연결구조의 성능검증 실험 (Performance Test of Corner Rigid Joint for Modular Structure using Channel and Coupler)

  • 이준경;이종순;이성형;김희성
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2255-2262
    • /
    • 2015
  • 최근 저심도의 도시철도 시스템이 제안되어 지상고가 형식의 민원과 지하경전철 형식의 비경제성을 극복하기 위한 연구가 진행중이다. 본 연구에서는 저심도 지하구조물의 경제성과 시공성 확보를 위하여 가시설을 대체하는 프리캐스트 형식의 모듈식 구조체를 적용하기 위하여 영구 강성벽체와 상부 슬래브간 연결부 조인트에 대한 구조적 성능을 검증하고자 실내 재하실험을 수행하였다. 성능재하 실험결과, 가시설 대체 강성벽체와 상부 슬래브간 연결부 구조는 휨모멘트 전달구조임을 확인하였다. 특히 휨 지배를 받는 상부에서는 채널형태보다는 커플러 조합이 휨 저항 성능이 30%정도 증가하여 유리함을 확인하였으나, 성능 개선이 필요한 것으로 확인되었다.

Development of New Detachable Connection for Glass Fiber Reinforced Polymer Considering of Short and Long-Term Behavior

  • Park, Don-U;Hwang, Kyung-Ju;Knippers, Jan
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.141-151
    • /
    • 2007
  • The appearance of many Glass Fiber Reinforced Plastic (GFRP) constructions look like ordinary steel construction, because GFRP has been imitated by the same way with the traditional steel's cross section as well as connection system. In terms of detachable connection, there was not enough appropriate option of GFRP connection, such as a traditional bolt connection for steel and wood structures. Most of all, from material characteristic of GFRP related to the deficient ductility, the shearstress principle of GFRP s not proper for the material property, which causes ineffective and not economic application of material. With this research problem, the innovative and detachable onnection system, which is more considered with appropriate material characteristic for FRP, is developed. Not only short time but also long time research with various connection variations is carried out.

  • PDF

건강증진모델학교 분석: 도시 지역 대규모 초등학교를 중심으로 (Analysis of Health Promoting Schools: Focusing on Large-sized Elementary Schools in Urban Areas)

  • 김미주
    • 한국학교보건학회지
    • /
    • 제30권3호
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the operational status and operational problems of health promoting model schools, particularly of the large-sized elementary schools in urban areas. Methods: The study analyzed the data of 14 large-sized elementary schools in urban areas selected from 85 health promoting model schools, an initiative led by the Ministry of Education from 2012 to 2014. Results: The study examined the operation process of health promoting schools in five stages; system development, needs survey & current status survey, school health policy development, program development & execution, and evaluation. In addition, the study discovered three key factors in operating health promoting schools and examined the status of each factor; connection with the curriculum, connection with the community, and consensus among members. Four problems were identified as operational problems: lack of research on faculty health issues, school physical environment and community resources, inadequate presentation of performance indicators, no close coordination in core task development and lack of linkage with the curriculum. Conclusion: It turned out the concept of health promoting school suggested by WHO was relatively faithfully realized in this study. Compared to small-sized elementary schools in rural areas, health promoting schools in this study showed better aspects overall. The connection with the community was good, but the connection with the curriculum was poor.

맨홀용 및 핸드홀용 지중 저압케이블 접속장치 개발 (Development of connection device for underground low voltage cable of manhole and handhole)

  • 이강중;이은정;주종민;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2005
  • It shows a tendency to increase rapidly underground of the city due to the build up of the large residential districts with industrial development, so there is required the development of the connection device for underground low voltage cable with high quality & convenient for use with consideration for installation condition of the underground. Hence, We will have the development of the connection device for underground low voltage cable, which is made waterproof perfectly under the flood of the underground for the long time, is convenient for use in spite of narrow area such as manhole or handhole, and can be able to prevent the release by the vibration.

  • PDF

지하철역과 쇼핑센터의 연계공간 구성적 특성에 관한 연구 - 서울시 소재 지하철 역사를 중심으로 - (A Study on the Characteristics of the Connecting Space between Subway & Shopping Area - Focused on the Subway Station in Seoul -)

  • 이남규
    • 한국실내디자인학회논문집
    • /
    • 제13권2호
    • /
    • pp.159-167
    • /
    • 2004
  • To realize the above concepts of underground space, several underground facilities are concentrated upon and around subway stations in harmony with underground pedestrian walkways. As a result, the reduction of transit time and pedestrian distance make it easy to get to an object. In this study, underground space is considered not just as pedestrian walkways, but as space for various activities and as a positive element in connection with its circumstances. The purpose of the study is to understand underground space's elements and develop more aesthetic and efficient design of the space to give mental composure and familiarity to users. The development of underground connection space is one of the methods to improve the quality of the whole downtown area. This paper studied the general characteristics of connection space and space improvements after spot inspections and suggested several aspects useful for substantial design as essential data for development of underground connection space.