• Title/Summary/Keyword: Connection Architecture

Search Result 788, Processing Time 0.025 seconds

Behavior of steel storage pallet racking connection - A review

  • Chen, Chulin;Shi, Lei;Shariati, Mahdi;Toghroli, Ali;Mohamad, Edy Tonnizam;Bui, Dieu Tien;Khorami, Majid
    • Steel and Composite Structures
    • /
    • v.30 no.5
    • /
    • pp.457-469
    • /
    • 2019
  • Steel pallet racking industry has globally used from the industrial revolution and has deeply evolved from hot-rolled profile into cold-formed profile to raise the optimization in engineering field. Nowadays, some studies regarding cold-formed steel profile have been performed, but fewer studies in terms of cold-formed pallet racking specifically in connection due to the semi-rigid behavior by lug-hooked into the upright have been conducted. The objective of this study is to review the related literature on steel storage racking connection behavior.

EasyConnection : An Efficient Approach to Integrating Heterogeneous Databases (EasyConnection : 이질 데이터베이스들의 효율적 연동 방식)

  • 변광준
    • The Journal of Society for e-Business Studies
    • /
    • v.4 no.3
    • /
    • pp.235-246
    • /
    • 1999
  • There have been several approaches to integrating heterogeneous database systems in enterprises. Due to their inherent limitations, however, it has been difficult to apply them to actual situations in enterprises. In this paper, we propose EasyConnection, a system that is based on the flexible and extensible architecture and overcomes the limitations of the previous approaches, EasyConnection consists of Wrappers, Sharing Manager, and Clients, and the connections among these components are based on CORBA. It can also be used as the information management mechanism for such application systems as ERP, PDM, and EAI.

  • PDF

Experimental studies on seismic behavior of steel coupling beams

  • Park, Wan-Shin;Yun, Hyun-Do;Chung, Jae-Yong;Kim, Yong-Chul
    • Structural Engineering and Mechanics
    • /
    • v.20 no.6
    • /
    • pp.695-712
    • /
    • 2005
  • Hybrid coupled shear walls in tall buildings are known as efficient structural systems to provide lateral resistance to wind and seismic loads. Multiple hybrid coupled shear walls throughout a tall building should be joined to provide additional coupling action to resist overturning moments caused by the lateral loading. This can be done using a coupling beam which connects two shear walls. In this study, experimental studies on the hybrid coupled shear wall were carried out. The main test variables were the ratios of coupling beam strength to connection strength. Finally, this paper provides background for rational design guidelines that include a design model to behave efficiently hybrid coupled shear walls.

Development of GASS2 through Improving Inter-component Connection and Communication Modules (연결성과 소통구조 모듈을 통한 차세대 범용 농업시스템 시뮬레이터 (GASS2)의 개발)

  • Kim, Tae Gon;Lee, Sung Yong;Yi, Ho Jae;Lee, Jeong Jae;Suh, Kyo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.29-36
    • /
    • 2014
  • The purpose of this study is to improve the Generic Agricultural Systems Simulator (GASS) which can simulate various rural systems based on object-oriented model. GASS provides the configuration platform of various system components to simplify integrated agricultural system models such as irrigation systems for rice farming. The new connection and communication modules of GASS improve applicability for modelling diverse systems. The geometric connection of GASS replaces topological connection, and communication protocols expand to analyze not only homogeneous system but also heterogeneous system. In this paper, we applied GASS2 to simulate the water heights of linked tanks and the simulation outputs were verified through comparing with analytical solutions of differential equations. The two new modules make it possible to analyze the 4-tank problem which includes topological and heterogenous issues with GASS2.

Cyclic behavior of connection between footing and concrete-infilled composite PHC pile

  • Bang, Jin-Wook;Hyun, Jung Hwan;Lee, Bang Yeon;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.741-754
    • /
    • 2014
  • The conventional PHC pile-footing connection is the weak part because the surface area and stiffness are sharply changed. The Composite PHC pile reinforced with the transverse shear reinforcing bars and infilled-concrete, hereafter ICP pile, has been developed for improving the flexural and shear performance. This paper investigates the cyclic behavior and performance of the ICP pile-footing connection. To investigate the behavior of the connection, one PHC and two ICP specimens were manufactured and then a series of cyclic loading tests were performed. From the test results, it was found that the ICP pile-footing connection exhibited higher cyclic behavior and connection performance compared to the conventional PHC pile-footing connection in terms of ductility ratio, stiffness degradation and energy dissipation capacity.

Strength of Exterior Flat Plate-Column Connections Subjected to Unbalanced Moment (불균형 휨모멘트를 받는 플랫 플레이트-기둥 외부접합부의 강도)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.470-481
    • /
    • 2003
  • Exterior plate-column connection has an unsymmetrical critical section for eccentric shear of which perimeter is less than that of interior connection, and hence, around the connection, unbalanced moment and eccentric shear are developed by both gravity load and lateral loads. Therefore, exterior connection is susceptible to punching shear failure. Current design provision cannot accurately explain strength of existing experiments, partly due to the complexity in the behavior of exterior plate-column connection, or partly due to the theoretical deficiency of the strength analysis model adopted. In the present study, nonlinear finite element analyses were performed for exterior connections belonging to continuous flat plate. For each direction of lateral load, the behavior and strength of exterior plate-column connection were quite different. Based on the numerical result, strength prediction model for exterior connection was proposed for each direction of lateral load. Compared with existing experiments, the proposed method was verified.

A Study on the Application of Biophilic Design Pattern in Educational space (아동 교육 공간의 바이오필릭 디자인 패턴 적용 분석)

  • Choi, Joo-young;Park, Sung-jun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.27 no.3
    • /
    • pp.3-14
    • /
    • 2020
  • The purpose of this study is to discuss the planning direction of educational spaces to support children's healthy and creative learning based on bio_philic theory. This study analyzed the characteristics of the application of biophilic patterns in children's education space through case analysis. The conclusion of this study is summarized as follows. As a result of the analysis of children's classroom space, the pattern of 'A(Visual connection with nature), F(Dynamic & Diffuse Light), K(Prospect)' shows high application rate, but the pattern of 'C(Non-Rhythmic Sensory Stimuli), G(Connection with Natural Systems), I(Material Connection with Nature)' shows low application rate. In particular, there is a lack of connection with patterns such as hearing, smell, touch, taste stimulation and water experience, and curiosity through exploration of nature about 'B(Non-visual connection with nature), E(Presence of Water), N(Risk/Peril)' changes in nature and ecosystem. In the corridor and rest space, the pattern of 'A(Visual connection with nature), D(Thermal & Airflow Variability), F(Dynamic & Diffuse Light), G(Connection with Natural Systems), K(Prospect)' shows high application rate, but 'B(Non-visual connection with nature)' shows low application rate. In addition, the application of patterns related to the stimulation of curiosity through direct exploration of nature and the exploration of the patterns of 'E(Presence of Water), N(Risk/Peril)' is insufficient. Therefore, in the case of classroom spaces, the active use of nature as it is should be considered within the scope that does not cause visual confusion, and it should provide an area that can be experienced through the five senses. And corridors and rest spaces should be designed to introduce more active natural elements as spaces to recover stress caused by learning. In other words, the characteristics of children's education facilities need to be connected between classroom space, corridor, rest space and external space. This study is meaningful in that it analyzes and derives the application characteristics of 'biophilic design' which affects the 'Attention Restoration' of children's educational spaces through foreign cases.

Evaluation of Compressive Chord Plastification of Circular Hollow Section X-joint Truss Connection (원형강관 X-이음 트러스접합부의 압축 주강관소성화 평가)

  • Lee, Kyungkoo;Sin, Yong Sup;Son, Eun Ji
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.447-454
    • /
    • 2015
  • The researches on circular hollow section(CHS) connections have been conducted continuously because of development of material properties and complex local behavior of the connections. The purpose of this study is that the effects of material strength and chord wall slenderness on chord plastification and strength of CHS X-joint truss connection under compression on branch member were evaluated. To this end, finite element analyses were performed for various connections, using ANSYS Mechanical APDL program. Based on the analysis results, the design strength of the connections according to chord plastification limit state in KBC were examined. Finally, special considerations for CHS X-joint connection design were suggested.

Punching performance of RC slab-column connections with inner steel truss

  • Shi, Qingxuan;Ma, Ge;Guo, Jiangran;Ma, Chenchen
    • Advances in concrete construction
    • /
    • v.14 no.3
    • /
    • pp.195-204
    • /
    • 2022
  • As a brittle failure mode, punching-shear failure can be widely found in traditional RC slab-column connections, which may lead to the entire collapse of a flat plate structure. In this paper, a novel RC slab-column connection with inner steel truss was proposed to enhance the punching strength. In the proposed connection, steel trusses, each of which was composed of four steel angles and a series of steel strips, were pre-assembled at the periphery of the column capital and behaved as transverse reinforcements. With the aim of exploring the punching behavior of this novel RC slab-column connection, a static punching test was conducted on two full-scaled RC slab specimens, and the crack patterns, failure modes, load-deflection and load-strain responses were thoroughly analyzed to explore the contribution of the applied inner steel trusses to the overall punching behavior. The test results indicated that all the test specimens suffered the typical punching-shear failure, and the higher punching strength and initial stiffness could be found in the specimen with inner steel trusses. The numerical models of tested specimens were analyzed in ABAQUS. These models were verified by comparing the results of the tests with the results of the analyzes, and subsequently the sensitivity of the punching capacity to different parameters was studied. Based on the test results, a modified critical shear crack theory, which could take the contribution of the steel trusses into account, was put forward to predict the punching strength of this novel RC slab-column connection, and the calculated results agreed well with the test results.

A study on rotational behaviour of a new industrialised building system connection

  • Moghadasi, Mostafa;Marsono, Abdul Kadir;Mohammadyan-Yasouj, Seyed Esmaeil
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.245-255
    • /
    • 2017
  • The performance of an Industrialised Building System (IBS) consists of prefabricated reinforced concrete components, is greatly affected by the behaviour of the connection between beam and columns. The structural characteristics parameters of a beam-to-column connection like rotational stiffness, strength and ductility can be explained by load-rotation relationship of a full scale H-subframe under gravitational load. Furthermore, the connection's degree of rigidity directly influences the behaviour of the whole frame. In this research, rotational behaviour of a patented innovative beam-to-column connection with unique benefits like easy installation, no wet work, no welding work at assembly site, using a hybrid behaviour of steel and concrete, easy replacement ability, and compatibility with architecture was investigated. The proposed IBS beam-to-column connection includes precast concrete components with embedded steel end connectors. Two full-scale H-subframes constructed with a new IBS and conventional cast in-situ reinforced concrete system beam-to-column connections were tested under incremental static loading. In this paper, load-rotation relationship and ratio of the rigidity of IBS beam-to-column connection are studied and compared with conventional monolithic reinforced concrete connection. It is concluded that this new IBS beam-to-column connection benefits from more rotational ductility than the conventional reinforced concrete connection. Furthermore, the semi-rigid IBS connection rigidity ratio is about 44% of a full rigid connection.