• Title/Summary/Keyword: Conical Beam

Search Result 48, Processing Time 0.02 seconds

A Satellite Tracking Method Using Rotation of Sub-Reflector for Naval Vessels Satellite Antenna System (부반사판 회전에 의한 함정용 위성 안테나의 위성 추적 방법)

  • Eom, Kwang-Sik;Park, Myung-Kwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.39-44
    • /
    • 2007
  • In this paper, satellite searching and tracking method for the satellite antenna in naval vessels system are proposed. For fast searching satellite, Wide Range Search(WRS) algorithm is proposed where the signal strength of side-lobe is utilized as well as that of main-lobe. Satellite tracking algorithm to stabilize satellite antenna is based on conical-scanning which is accomplished by the use of the sub-reflector located in front of the focus of the reflector. The sub-reflector rotates about a slightly tilted axis by means of a motor and shapes the antenna beam to utilize stabilization. To show the validity of the proposed method, an experimental example is represented.

Dynamic analysis of a functionally graded tapered rotating shaft under thermal load via differential quadrature finite elements method

  • Fethi, Hadjoui;Ahmed, Saimi;Ismail, Bensaid;Abdelhamid, Hadjoui
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.1
    • /
    • pp.19-49
    • /
    • 2023
  • The present study proposes a theoretical and numerical investigation on the dynamic response behaviour of a functional graded (FG) ceramic-metal tapered rotor shaft system, by the differential quadrature finite elements method (DQFEM) to identify the natural frequencies for modelling and analysis of the structure with suitable validations. The purpose of this paper is to explore the influence of heat gradients on the natural frequency of rotation of FG shafts via three-dimensional solid elements, as well as a theoretical examination using the Timoshenko beam mode, which took into account the gyroscopic effect and rotational inertia. The functionally graded material's distribution is described by two distribution laws: the power law and the exponential law. To simulate varied thermal conditions, radial temperature distributions are obtained using the nonlinear temperature distribution (NLTD) and exponential temperature distribution (ETD) approaches. This work deals with the results of the effect on the fundamental frequencies of different material's laws gradation and temperature gradients distributions. Attempts are conducted to identify adequate explanations for the behaviours based on material characteristics. The effect of taper angle and material distribution on the dynamic behaviour of the FG conical rotor system is discussed.

Optimization of the cross-section regarding the stability of nanostructures according to the dynamic analysis

  • Qiuyang Cheng;H. Elhosiny Ali;Ibrahim Albaijan
    • Advances in concrete construction
    • /
    • v.15 no.4
    • /
    • pp.215-228
    • /
    • 2023
  • The vibrational behavior of nanoelements is critical in determining how a nanostructure behaves. However, combining vibrational analysis with stability analysis allows for a more comprehensive knowledge of a structure's behavior. As a result, the goal of this research is to characterize the behavior of nonlocal nanocyndrical beams with uniform and nonuniform cross sections. The nonuniformity of the beams is determined by three distinct section functions, namely linear, convex, and exponential functions, with the length and mass of the beams being identical. For completely clamped, fully pinned, and cantilever boundary conditions, Eringen's nonlocal theory is combined with the Timoshenko beam model. The extended differential quadrature technique was used to solve the governing equations in this research. In contrast to the other boundary conditions, the findings of this research reveal that the nonlocal impact has the opposite effect on the frequency of the uniform cantilever nanobeam. Furthermore, since the mass of the materials employed in these nanobeams is designed to remain the same, the findings may be utilized to help improve the frequency and buckling stress of a resonator without requiring additional material, which is a cost-effective benefit.

Three-Dimensional Image Reconstruction from Compton Scattered Data Using the Row-Action Maximum Likelihood Algorithm (행작용 최대우도 알고리즘을 사용한 컴프턴 산란 데이터로부터의 3차원 영상재구성)

  • Lee, Mi-No;Lee, Soo-Jin;Nguyen, Van-Giang;Kim, Soo-Mee;Lee, Jae-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.56-65
    • /
    • 2009
  • Compton imaging is often recognized as a potentially more valuable 3-D technique in nuclear medicine than conventional emission tomography. Due to inherent computational limitations, however, it has been of a difficult problem to reconstruct images with good accuracy. In this work we show that the row-action maximum likelihood algorithm (RAMLA), which have proven useful for conventional tomographic reconstruction, can also be applied to the problem of 3-D reconstruction of cone-beam projections from Compton scattered data. The major advantage of RAMLA is that it converges to a true maximum likelihood solution at an order of magnitude faster than the standard expectation maximiation (EM) algorithm. For our simulations, we first model a Compton camera system consisting of the three pairs of scatterer and absorber detectors placed at x-, y- and z-axes, and generate conical projection data using a software phantom. We then compare the quantitative performance of RAMLA and EM reconstructions in terms of the percentage error. The net conclusion based on our experimental results is that the RAMLA applied to Compton camera reconstruction significantly outperforms the EM algorithm in convergence rate; while computational costs of one iteration of RAMLA and EM are about the same, one iteration of RAMLA performs as well as 128 iterations of EM.

3D Lithography using X-ray Exposure Devices Integrated with Electrostatic and Electrothermal Actuators

  • Lee, Kwang-Cheol;Lee, Seung S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • We present a novel 3D fabrication method with single X-ray process utilizing an X-ray mask in which a micro-actuator is integrated. An X-ray absorber is electroplated on the shuttle mass driven by the integrated micro-actuator during deep X-ray exposures. 3D microstructures are revealed by development kinetics and modulated in-depth dose distribution in resist, usually PMMA. Fabrication of X-ray masks with integrated electrothermal xy-stage and electrostatic actuator is presented along with discussions on PMMA development characteristics. Both devices use $20-\mu\textrm{m}$-thick overhanging single crystal Si as a structural material and fabricated using deep reactive ion etching of silicon-on-insulator wafer, phosphorous diffusion, gold electroplating, and bulk micromachining process. In electrostatic devices, $10-\mu\textrm{m}-thick$ gold absorber on $1mm{\times}1mm$ Si shuttle mass is supported by $10-\mu\textrm{m}-wide$, 1-mm-long suspension beams and oscillated by comb electrodes during X-ray exposures. In electrothermal devices, gold absorber on 1.42 mm diameter shuttle mass is oscillated in x and y directions sequentially by thermal expansion caused by joule heating of the corresponding bent beam actuators. The fundamental frequency and amplitude of the electrostatic devices are around 3.6 kHz and $20\mu\textrm{m}$, respectively, for a dc bias of 100 V and an ac bias of 20 VP-P (peak-peak). Displacements in x and y directions of the electrothermal devices are both around $20{\;}\mu\textrm{m}$at 742 mW input power. S-shaped and conical shaped PMMA microstructures are demonstrated through X-ray experiments with the fabricated devices.

Three Dimensional Analysis of Maxillary Mesiodens Using Dental CBCT and Relationship Between the Mesiodens and Diastema (치과용 CBCT를 이용한 상악 정중치의 3차원 분석 및 정중치와 정중이개와의 관계분석)

  • Kang, Eunjoo;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.260-267
    • /
    • 2013
  • The aim of this study was to analyze the three dimensional characteristics of the size, shape and location of mesiodens and their effect on permanent teeth arrangement using Cone-beam computed tomography(CBCT). 191 patients under 15 years old who had visited the hospital between June 2006 and December 2012 and taken CBCT were investigated. Among them, 43 patients with diastema were analyzed to investigate the correlation between the amount of diastema and the mesiodens. The results showed that mesiodens were found in males 3.9 times more than females and found most in 7 years old. The mean length of mesiodens was 13 mm and the width was 6.8 mm. The conical shape comprised of 52.9%. Many mesiodens were located in the palatal side rather than the labial side and located vertically near the crown. 63.0% of mesiodens were reversed and the common complications were delayed eruption followed by diastema, and teeth rotation. And the amount of diastema had correlation with size and mesiodistal position of the mesiodens. The current study used 3D analysis to show the size and position of mesiodens and occurrence distribution of complication. Among these, the amount of diastema had shown the correlation with the size and mesiodistal position of mesiodens.

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.

Production of $[^{18}F]F_2$ Gas for Electrophilic Substitution Reaction (친전자성 치환반응을 위한 $[^{18}F]F_2$ Gas의 생산 연구)

  • Moon, Byung-Seok;Kim, Jae-Hong;Lee, Kyo-Chul;An, Gwang-Il;Cheon, Gi-Jeong;Chun, Kwon-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.228-232
    • /
    • 2006
  • Purpose: electrophilic $^{18}F(T_{1/2}=110\;min)$ radionuclide in the form of $[^{18}F]F_2$ gas is of great significance for labeling radiopharmaceuticals for positron omission tomography (PET). However, its production In high yield and with high specific radioactivity is still a challenge to overcome several problems on targetry. The aim of the present study was to develop a method suitable for the routine production of $[^{18}F]F_2$ for the electrophilic substitution reaction. Materials and Methods: The target was designed water-cooled aluminum target chamber system with a conical bore shape. Production of the elemental fluorine was carried out via the $^{18}O(p,n)^{18}F$ reaction using a two-step irradiation protocol. In the first irradiation, the target filled with highly enriched $^{18}O_2$ was irradiated with protons for $^{18}F$ production, which were adsorbed on the inner surface of target body. In the second irradiation, the mixed gas ($1%[^{19}F]F_2/Ar$) was leaded into the target chamber, fellowing a short irradiation of proton for isotopic exchange between the carrier-fluorine and the radiofluorine absorbed in the target chamber. Optimization of production was performed as the function of irradiation time, the beam current and $^{18}O_2$ loading pressure. Results: Production runs was performed under the following optimum conditions: The 1st irradiation for the nuclear reaction (15.0 bar of 97% enriched $^{18}O_2$, 13.2 MeV protons, 30 ${\mu}A$, 60-90 min irradiation), the recovery of enriched oxygen via cryogenic pumping; The 2nd irradiation for the recovery of absorbed radiofluorine (12.0 bar of 1% $[^{19}F]fluorine/argon$ gas, 13.2 MeV protons, 30 ${\mu}A$, 20-30 min irradiation) the recovery of $[^{18}F]fluorine$ for synthesis. The yield of $[^{18}F]fluorine$ at EOB (end of bombardment) was achieved around $34{\pm}6.0$ GBq (n>10). Conclusion: The production of $^{18}F$ electrophilic agent via $^{18}O(p,n)^{18}F$ reaction was much under investigation. Especially, an aluminum gas target was very advantageous for routine production of $[^{18}F]fluorine$. These results suggest the possibility to use $[^{18}F]F_2$ gas as a electrophilic substitution agent.