• 제목/요약/키워드: Conformal may

검색결과 41건 처리시간 0.024초

Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

  • Mattes, Malcolm D.;Zhou, Ying;Berry, Sean L.;Barker, Christopher A.
    • Radiation Oncology Journal
    • /
    • 제34권2호
    • /
    • pp.145-155
    • /
    • 2016
  • Purpose: Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Materials and Methods: Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. Results: In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung $V_{20}$ (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum $D_{max}$ (13.6 vs. 38.9 Gy), bowel $D_{200cc}$ (7.3 vs. 23.1 Gy), femur $D_{50}$ (34.6 vs. 57.2 Gy), and genitalia $D_{max}$ (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus $D_{mean}$ (16.9 vs. 22.4 Gy), brachial plexus $D_5$ (57.4 vs. 61.3 Gy), bladder $D_5$ (26.8 vs. 36.5 Gy), and femur $D_{50}$ (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Conclusion: Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

전이학습 기반의 CNN을 이용한 컨포멀 코팅 PCB에 발생한 기포 검출 방법 (A Bubble Detection Method for Conformal Coated PCB Using Transfer Learning based CNN)

  • 이동희;조성령;정경훈;강동욱
    • 방송공학회논문지
    • /
    • 제26권6호
    • /
    • pp.809-812
    • /
    • 2021
  • PCB를 코팅하는 과정에서 기포가 발생하면 회로 오작동의 원인이 되기 때문에 기포 검출은 컨포멀 코팅 검사에서 매우 중요한 작업이다. 이전 연구에서는 기포의 밝기 특성을 이용하여 기포의 후보를 추출하고, 합성곱 신경망(CNN: Convolutional Neural Networks)을 이용하여 추출된 후보를 검증하였다. 본 논문에서는 전이학습 기반의 합성곱 신경망 모델을 이용하여 기포를 검출하는 방법을 제안한다. 이를 위해 합성곱 신경망 모델로 VGGNet을 사용하고, 분류층(Classification Layer)으로 시그모이드(Sigmoid)를 적용하였으며, 마지막 합성곱층(Convolutional Layer)과 분류층을 함께 학습하는 전이학습 방법을 적용하였다. 제안하는 방법의 기포 검출 성능은 F1-score 0.9044로서 이전 연구 대비 약 0.17의 개선 효과를 나타내었다.

Three-dimensional conformal radiotherapy for portal vein tumor thrombosis alone in advanced hepatocellular carcinoma

  • Lee, Ju Hye;Kim, Dong Hyun;Ki, Yong Kan;Nam, Ji Ho;Heo, Jeong;Woo, Hyun Young;Kim, Dong Won;Kim, Won Taek
    • Radiation Oncology Journal
    • /
    • 제32권3호
    • /
    • pp.170-178
    • /
    • 2014
  • Purpose: We sought to evaluate the clinical outcomes of 3-dimensional conformal radiation therapy (3D-CRT) for portal vein tumor thrombosis (PVTT) alone in patients with advanced hepatocellular carcinoma. Materials and Methods: We retrospectively analyzed data on 46 patients who received 3D-CRT for PVTT alone between June 2002 and December 2011. Response was evaluated following the Response Evaluation Criteria in Solid Tumors. Prognostic factors and 1-year survival rates were compared between responders and non-responders. Results: Thirty-seven patients (80.4%) had category B Child-Pugh scores. The Eastern Cooperative Oncology Group performance status score was 2 in 20 patients. Thirty patients (65.2%) had main or bilateral PVTT. The median irradiation dose was 50 Gy (range, 35 to 60 Gy) and the daily median dose was 2 Gy (range, 2.0 to 2.5 Gy). PVTT response was classified as complete response in 3 patients (6.5%), partial response in 12 (26.1%), stable disease in 19 (41.3%), and progressive disease in 12 (26.1%). There were 2 cases of grade 3 toxicities during or 3 months after radiotherapy. Twelve patients in the responder group (15 patients) received at least 50 Gy irradiation, but about 84% of patients in the non-responder group received less than 50 Gy. The 1-year survival rate was 66.8% in responders and 27.4% in non-responders constituting a statistically significant difference (p = 0.008). Conclusion: Conformal radiotherapy for PVTT alone could be chosen as a palliative treatment modality in patients with unfavorable conditions (liver, patient, or tumor factors). However, more than 50 Gy of radiation may be required.

저전압 VDMOS 의 ON-저항 모델링 (An Advanced On-Resistance Model for Low Voltage VDMOS)

  • 김성동;김일중;최연익;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.166-170
    • /
    • 1991
  • An advanced on-resistance model of VDMOS devices in the low voltage regime is proposed and verified by 2-D device simulations. The model considers the lateral gaussian doping profiles in the channel region and exact current spreading angles in the epitaxial layer for both linear and cellular geometries by employing the conformal mapping. It is found out that the on-resistance of low voltage VDMOS may be overestimated considerably if it is analyzed by the conventional method. The 2-D device simulation results show that the proposed model is valid for all ranges of cell spacings and breakdown voltages.

  • PDF

A numerical parametric study on hydrofoil interaction in tandem

  • Kinaci, Omer Kemal
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.25-40
    • /
    • 2015
  • Understanding the effects of the parameters affecting the interaction of tandem hydrofoil system is a crucial subject in order to fully comprehend the aero/hydrodynamics of any vehicle moving inside a fluid. This study covers a parametric study on tandem hydrofoil interaction in both potential and viscous fluids using iterative Boundary Element Method (BEM) and RANSE. BEM allows a quick estimation of the flow around bodies and may be used for practical purposes to assess the interaction inside the fluid. The produced results are verified by conformal mapping and Finite Volume Method (FVM). RANSE is used for viscous flow conditions to assess the effects of viscosity compared to the inviscid solutions proposed by BEM. Six different parameters are investigated and they are the effects of distance, thickness, angle of attack, chord length, aspect ratio and tapered wings. A generalized 2-D code is developed implementing the iterative procedure and is adapted to generate results. Effects of free surface and cavitation are ignored. It is believed that the present work will provide insight into the parametric interference between hydrofoils inside the fluid.

Advances and Challenges in Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

  • Qu, Song;Liang, Zhong-Guo;Zhu, Xiao-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1687-1692
    • /
    • 2015
  • Nasopharyngeal carcinoma is an endemic disease within specific regions in the world. Radiotherapy is the main treatment. In recent decades, intensity-modulated radiation therapy has undergone a rapid evolution. Compared with two-dimensional radiotherapy and/or three-dimensional conformal radiotherapy, evidence has shown it may improve quality of life and prognosis for patients with nasopharyngeal carcinoma. In addition, helical tomotherapy is an emerging technology of intensity-modulated radiation therapy. Its superiority in dosimetric and clinical outcomes has been demonstrated when compared to traditional intensity-modulated radiation therapy. However, many challenges need to be overcome for intensity-modulated radiation therapy of nasopharyngeal carcinoma in the future. Issues such as the status of concurrent chemotherapy, updating of target delineation, the role of replanning during IMRT, the causes of the main local failure pattern require settlement. The present study reviews traditional intensity-modulated radiation therapy, helical tomotherapy, and new challenges in the management of nasopharyngeal carcinoma.

Enhanced Stability of LiCoO2 Cathodes in Lithium-ion Batteries Using Surface Modification by Atomic Layer Deposition

  • Jung, Yoon-S.;Cavanagh, Andrew S.;Dillon, Anne C.;Groner, Markus D.;George, Steven M.;Lee, Se-Hee
    • 한국세라믹학회지
    • /
    • 제47권1호
    • /
    • pp.61-65
    • /
    • 2010
  • Ultrathin atomic layer deposition (ALD) coatings were found to enhance the performance of lithium-ion batteries (LIBs). Previous studies have demonstrated that $LiCoO_2$ cathode powders coated with metal oxides with thicknesses of $\sim100-1000{\AA}$ grown using wet chemical techniques improved LIB performance. In this study, $LiCoO_2$ powders were coated with conformal $Al_2O_3$ ALD films with thicknesses of only $\sim3-4{\AA}$ established using 2 ALD cycles. The coated $LiCoO_2$ powders exhibited a capacity retention of 89% after 120 charge-discharge cycles in the 3.3~4.5 V (vs. $Li/Li^+$) range. In contrast, the bare $LiCoO_2$ powders displayed only a 45% capacity retention. This dramatic improvement may result from the ultrathin $Al_2O_3$ ALD film acting to minimize Co dissolution or to reduce surface electrolyte reactions.

An Image-guided Radiosurgery for the Treatment of Metastatic Bone Tumors using the CyberKnife Robotic System

  • Cho, Chul-Koo
    • 대한골관절종양학회지
    • /
    • 제13권1호
    • /
    • pp.14-21
    • /
    • 2007
  • Bone is a common site for metastatic spread from many kinds of malignancies. The morbidity associated with this metastatic spread can be significant, including severe pain. When it comes to spinal metastasis, occupying nearly 40% of skeletal metastases, the risks of complications, such as vertebral body collapse, nerve root impingement, or spinal cord compression, are also significant. Because of the necessity of preserving the integrity of the spinal column and the proximity of critical structures, surgical treatment has limitations when durable local control is desired. Radiotherapy, therefore, is often used as an adjunct treatment or as a sole treatment. A considerable limitation of standard radiotherapy is the reported recurrence rate or ineffective palliation of pain, either clinically or symptomatically. This may be due to limited radiation doses to tumor itself because of the proximity of critical structures. CyberKnife is an image-guided robotic radiosurgical system. The image guidance system includes a kilovoltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator (6 MV) mounted on a robotic arm. Highly conformal fields and hypofractionated radiotherapy schedules are increasingly being used as a means to achieve biologic dose escalation for body tumors. Therefore, we can give much higher doses to the targeted tumor volume with minimizing doses to the surrounding critical structures, resulting in more effective local control and less severe side effects, compared to conventional fractionated radiotherapy. A description of this technology and a review of clinical applications to bone metastases are detailed herein.

  • PDF

Reirradiation of head and neck cancer in the era of intensity-modulated radiotherapy: patient selection, practical aspects, and current evidence

  • Kim, Yeon Sil
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.1-15
    • /
    • 2017
  • Locoregional failure is the most frequent pattern of failure in locally advanced head and neck cancer patients and it leads to death in most of the patients. Second primary tumors occurring in the other head and neck region reach up to almost 40% of long-term survivors. Recommended and preferred retreatment option in operable patients is salvage surgical resection, reporting a 5-year overall survival of up to 40%. However, because of tumor location, extent, and underlying comorbidities, salvage surgery is often limited and compromised by incomplete resection. Reirradiation with or without combined chemotherapy is an appropriate option for unresectable recurrence. Reirradiation is carefully considered with a case-by-case basis. Reirradiation protocol enrollment is highly encouraged prior to committing patient to an aggressive therapy. Radiation doses greater than 60 Gy are usually recommended for successful salvage. Despite recent technical improvement in intensity-modulated radiotherapy (IMRT), the use of concurrent chemotherapy, and the emergence of molecularly targeted agents, careful patient selection remain as the most paramount factor in reirradiation. Tumors that recur or persist despite aggressive prior chemoradiation therapy imply the presence of chemoradio-resistant clonogens. Treatment protocols that combine novel targeted radiosensitizing agents with conformal high precision radiation are required to overcome the resistance while minimizing toxicity. Recent large number of data showed that IMRT may provide better locoregional control with acceptable acute or chronic morbidities. However, additional prospective studies are required before a definitive conclusion can be drawn on safety and effectiveness of IMRT.

직선늑골선형(直線肋骨船型)의 수평(水平) 및 비틂진동(振動)에 있어서의 2차원적(次元的) 부가관성계수(附加慣性係數) (Two Dimensional Added Inertia Coefficients for Straight Framed Hull Forms in Horizontal and Torsional Vibration.)

  • 김사수
    • 대한조선학회지
    • /
    • 제12권2호
    • /
    • pp.3-12
    • /
    • 1975
  • As for two dimensional added mass coefficients for straight framed hull forms in a free surface of an ideal fluid, theoretical calculations by F.M. Lewis, vertical, K. Wendel, J.H. Hwang, and etc. are available; vertical modes of rectangular and triangle sections by Lewis, vertical, horizontal and torsional models of rectangular and triangle section by Wendel, and systematical calculations for vertical modes of single chine forms by Hwang. In this paper, employing the conformal transformation by which a unit circle and its exterior region can conformally mapped to a polygon and its exterior region, the author calculated two dimensional added inertia coefficients systematically for straight framed sections with single chine in horizontal and torsional modes of vibrations. As the results, it was found that sloping side angle is an important factor measuring the magnitude of two dimensional added inertia coefficient for a set of given values of the sectional area coefficient and the beam-draft ratio. To grasp it cleary in physical sense, pressure distributions are investigated for some typical section contours. The numerical results are presented graphically in the form of two dimensional added sectional area coefficients with beam-draft ratios and sloping side angles as parameters, so that the data may conveniently utilized for estimation of the added inertia coefficients based on a three parameter technique.

  • PDF