• Title/Summary/Keyword: Confirm

Search Result 13,771, Processing Time 0.042 seconds

Dwell Time Optimization of Alert-Confirm Detection for Active Phased Array Radars

  • Kim, Eun Hee;Park, JoonYong
    • Journal of electromagnetic engineering and science
    • /
    • v.19 no.2
    • /
    • pp.107-114
    • /
    • 2019
  • Alert-confirm detection is a highly efficient method to improve phased array radar search performance. It comprises sequential detection in two steps: alert detection, in which a target is detected at a low detection threshold, and confirm detection, which is triggered by alert detection with a longer dwell time to minimize false alarms. This paper provides a design method for applying the alert-confirm detection to multifunctional radars. We find optimum dwell times and false alarm probabilities for each alert detection and confirm detection under the dual constraints of total false alarm probability and maximum allowable dwell time per position. These optimum values are expressed as a function of the mean new target appearance rate. The proposed alert-confirm detection increases the maximum detection range even with a shorter frame time than that of uniform scanning.

A Study on Design and Analysis of an Alert-Confirm Detection Method (Alert-Confirm 탐지 방식의 설계 및 성능 분석에 관한 연구)

  • Eunhee Kim;Hyunsu Oh;Sawon Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.140-146
    • /
    • 2024
  • Active electronically scanning antennas are faster and more flexible in beam-scheduling than mechanical antennas. Thus, they require an advanced resource management or detection methods to operate efficiently. In a surveillance radar performing periodic detection, alert-confirm detection is an excellent method to improve the cumulative detection probability by reducing the period while maintaining the detection probability. This paper proposes a design method for alert-confirm detection based on the parameters of the conventional design. We developed a simulator based on simulink@matworks and verified the result through Monte Carlo simulation.

CT-Based Leiden Score Outperforms Confirm Score in Predicting Major Adverse Cardiovascular Events for Diabetic Patients with Suspected Coronary Artery Disease

  • Zinuan Liu;Yipu Ding;Guanhua Dou;Xi Wang;Dongkai Shan;Bai He;Jing Jing;Yundai Chen;Junjie Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.939-948
    • /
    • 2022
  • Objective: Evidence supports the efficacy of coronary computed tomography angiography (CCTA)-based risk scores in cardiovascular risk stratification of patients with suspected coronary artery disease (CAD). We aimed to compare two CCTA-based risk score algorithms, Leiden and Confirm scores, in patients with diabetes mellitus (DM) and suspected CAD. Materials and Methods: This single-center prospective cohort study consecutively included 1241 DM patients (54.1% male, 60.2 ± 10.4 years) referred for CCTA for suspected CAD in 2015-2017. Leiden and Confirm scores were calculated and stratified as < 5 (reference), 5-20, and > 20 for Leiden and < 14.3 (reference), 14.3-19.5, and > 19.5 for Confirm. Major adverse cardiovascular events (MACE) were defined as the composite outcomes of cardiovascular death, nonfatal myocardial infarction (MI), stroke, and unstable angina requiring hospitalization. The Cox model and Kaplan-Meier method were used to evaluate the effect size of the risk scores on MACE. The area under the curve (AUC) at the median follow-up time was also compared between score algorithms. Results: During a median follow-up of 31 months (interquartile range, 27.6-37.3 months), 131 of MACE were recorded, including 17 cardiovascular deaths, 28 nonfatal MIs, 64 unstable anginas requiring hospitalization, and 22 strokes. An incremental incidence of MACE was observed in both Leiden and Confirm scores, with an increase in the scores (log-rank p < 0.001). In the multivariable analysis, compared with Leiden score < 5, the hazard ratios for Leiden scores of 5-20 and > 20 were 2.37 (95% confidence interval [CI]: 1.53-3.69; p < 0.001) and 4.39 (95% CI: 2.40-8.01; p < 0.001), respectively, while the Confirm score did not demonstrate a statistically significant association with the risk of MACE. The Leiden score showed a greater AUC of 0.840 compared to 0.777 for the Confirm score (p < 0.001). Conclusion: CCTA-based risk score algorithms could be used as reliable cardiovascular risk predictors in patients with DM and suspected CAD, among which the Leiden score outperformed the Confirm score in predicting MACE.

A Study on the Remain Life with Aging in 22kV CV cable (22kV 전력케이블의 열화 판정에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

CN AND CH BAND STRENGTH VARIATIONS IN M71 GIANTS

  • LEE SANG-GAK
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.23-31
    • /
    • 2005
  • CN and CH band strengths for fourteen bright giants in the globular cluster M71 have been measured from archival spectra obtained with the Multiple Mirror Telescope. Adding the collected. data from the literature we confirm a bimodality of CN distribution on the red giant branch and the honzontal branch, and CN-CH anti-correlations on the lower giant branch and horizontal branch. However a CN-CH anti-correlation on the upper red giant branch is not quite clear as those of other branches. The small number If statistics could not be excluded as a possible cause. To confirm this, a greater number of sample stars are needed. We also confirm that the ratio of CN-strong to CN-weak stars is quite different from that in 47 Tuc, although the anti-correlation between CN and CH bands, the bimodality of the CN distribution, and the spatial distribution of CN stars in M71 are found to be similar to those III 47 Tuc.

The effect of cathodic protection system by means of zinc sacrificial anode on pier in Korea

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1206-1211
    • /
    • 2014
  • This study has been conducted to confirm the effect of sacrificial anode cathodic protection system for 90 days to protect corrosion on pier that is located in Korea. The cathodically protected structure was a slab and a pile cap. Before the construction of cathodic protection system, the macrography was carried out. As a result of the macrography, many corrosion traces were confirmed in this structure. The trace was mainly focused on joint and zones that concrete cover was eliminated. To apply the cathodic protection system, many onsite techniques have been adopted. In addition, to confirm the inner state of steel in concrete properly, a corrosion monitoring sensor (DMS-100, Conclinic Co. Ltd) has been applied. Test factors were corrosion & cathodic protection potential, 4 hour depolarization potential, resistivity and current density. After 90 days from the installation of cathodic protection system, it could confirm that proper corrosion protection effect was obtained by considering the result of tests.

The Moderate Effect of SPC on the Relations Between Practicing JIT and Production Performance

  • Park, Jeong-Soo
    • International Journal of Quality Innovation
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 2009
  • Our goal of this study is to confirm whether manufacturing companies' practicing JIT production system have positive effect on production performances and to confirm that manufacturing companies' practicing SPC shows positive moderate effect on the relation between practicing JIT and their production performances. Based on empirical study to manufacturing companies nationwide, we can conclude that taking JIT practices of sample companies has positive effect on production performances and, moreover, practicing SPC has positive moderate effect on the relation between JIT practices and production performances. These conclusion represents managerial implication that concurrent practicing JIT and SPC could generate more improved production performances.

A STUDY OF THE PHOTOTOXICITY OF ORANGE FLOWER ABSOLUTE

  • Yang, Hai-Joo;Lee, Neung-An
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 1987
  • We have confirmed the phototoxicity of orange flower absolute, studied the phototoxic ingredient and developed a method to eliminate it. To confirm the phototoxicity, we tested French orange flower absolute, Moroccan absolute and Egyptian absolute with Hartley strain guinea Pig under UV irradiation ranging from 320400 nm supplied with fluorescent lamps. Using a combination of isolation techniques including HPLC and IR, we were able to confirm that the phototoxic agent was bergapten. The development of a non-phototoxic orange flower absolute using ion exchange chromatography is described.

  • PDF

Development of Consumer Adviser Educational Program (소비자상담사 교육프로그램에 관한 연구 -필수이수교과목의 교과내용과 현장실습교육을 중심으로-)

  • 송인숙
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.3
    • /
    • pp.9-20
    • /
    • 1996
  • The purpose of this study is to develop the educational program of consumer adviser. The educational program proposed in previous study is consisted of the acquisition of 5 require and 2 optional subjects, and field education. For this, based on the role and capacity of consumer adviser we explain in detail the contents of required subjects. And we confirm the necessity and significance of field education. Finally we investigate the confirm the necessity and significance of field education. Finally we investigate the contents of field education and suggest the system and course of desirable field education through case study of several universities.

  • PDF

Effect of β-glucan on Epithelial Inflammation Induced by Atopic Dermatitis through Endocannabinoid System Activity (β-glucan의 Endocannabinoid system 활성을 통한 아토피피부염 유발 상피 염증 억제 효과)

  • Seo, Il Bok;Ahn, Sang Hyun;Kim, Ki Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.22-30
    • /
    • 2020
  • Objectives This study was conducted to confirm the inhibitory effect of β-glucan on epithelial inflammation induced by atopic dermatitis through Endocannabinoid system (ECS) activity. Methods Six-week-old NC/Nga mice were divided into a control group (Ctrl), atopic dermatitis elicitation group (ADE), and a β-glucan-treated group (β-glucan treatment after atopy dermatitis elicitation, β-GT). After 3 weeks, CB1, CB2, and GPR55 were observed to confirm the regulation of ECS activity, and filaggrin in the stratum corneum and Kallikrein-related peptidase (KLK) 7 in the stratum corneum and protease activated receptor (PAR)-2 were observed to confirm the inhibition of the inflammation, Phosphorylated extracellular signal-related kinase (p-ERK), Phosphorylated mammalian target of rapamycin (p-mTOR), and E-Cadherin were observed to confirm microenvironmental regulation. Results β-GT was significantly increased in CB1, CB2, and GPR55 positive reactions compared to that of the ADE. In positive reaction of the filaggrin in the stratum corneum, β-GT was significantly increased than that of the ADE. For KLK7 positive and PAR2 positive, β-GT was significantly reduced compared to the ADE. The p-ERK-positive and p-mTOR-positive reactions were significantly reduced in β-GT than in ADE. E-cadherin positive reaction was significantly increased in β-GT than in ADE (All p < 0.01). Conclusions It was confirmed that β-glucan has the effect of inhibiting the epithelium induced by atopic dermatitis through the ECS activity.