• 제목/요약/키워드: Confined jet

검색결과 75건 처리시간 0.023초

유출홀을 사용한 배열충돌제트의 열/물질전달 특성 (Heat/mass transfer characteristics of arrays of impingement jets using effusion holes)

  • 윤필현;황상동;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.125-131
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Spent fluid makes a crossflow in the confined space. The crossflow reduces heat/mass transfer at the small gap distance between the jet plate and impingement surface because of reentrainment of the spent fluid. The present study suggests a new exhaust system having effusion holes in the impinging jet plate. The spent air flow out after impingement just through effusion holes located in the upper plate. This system increases heat/mass transfer coefficients and uniformity for small gap distances$(H/d{\leq}2)$

  • PDF

정전분무모드에 관한 액적특성의 실험적 연구 (Experimental Study of Droplet Characteristics Related to Electrospray Mode)

  • 김지엽;이도현;조주형;홍정구
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.26-35
    • /
    • 2022
  • Electrospray is a method of atomizing fluid using high voltage supply and capable of generating continuous flow and coherent size of droplets. Electrical system and properties of fluids has enabled electrospray to have various spray modes. However, its studies have been confined only in Cone jet, which is more stable and easier to manipulate droplets' size than other spraying modes. Therefore, it is necessary to investigate and compare other spraying modes based on experimental parameters and physical properties of fluids. This research paper identified nine different spray modes. It was found out that Sauter Mean Diameter (SMD) is proportional to flow rate of fluids and maximum difference among spray modes was 1.7 times. On the other hand, SMD standard deviation had low variations on specific flow rates of fluids. Pulsed jet mode recorded the largest SMD standard deviation, while Spindle recorded the lowest.

다양한 노즐 수 변화에 따른 충돌 제트의 열전달 특성에 관한 수치적 연구 (A Numerical Study on the Heat Transfer Characteristics of the Multiple Slot Impinging Jet)

  • 김상근;하만영;손창민
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.754-761
    • /
    • 2011
  • The present study numerically investigates two-dimensional flow and heat transfer in the multiple confined impinging slot jet. Numerical simulations are performed for the different Reynolds numbers(Re=100 and 200) in the range of nozzles from 1 to 9 and height ratios(H/D) from 2 to 5, where H/D is the ratio of the channel height to the slot width. The vector plots of velocity profile, stagnation and averaged Nusselt number distributions are presented in this paper. The dependency of thermal fields on the Reynolds number, nozzle number and height ratio can be clarified by observing the Nusselt number as heat transfer characteristic at the stagnation point and impingement surface. The Nusselt number at the stagnation point of the central slot shows unsteadiness at H/D=3 and Re=200. The value of Nusselt number at the stagnation point of the central slot decreases with higher Reynolds number and number of nozzle although overall area averaged Nusselt number increases. Hence careful selection of geometrical parameters and number of nozzle are necessary for optimization of the heat transfer performance of multiple slot impinging jet.

지하 복합발전 플랜트 내부의 가스 누출 특성에 대한 수치해석 연구 (Numerical Study on Characteristics of Gas Leakage in an Underground Combined Cycle Power Plant)

  • 방주원;성건혁;유홍선;이성혁
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.594-600
    • /
    • 2016
  • 본 연구에서는 수치해석 기법을 활용하여 간략화한 지하 복합발전 플랜트 내 파공 위치에 따른 가스 확산 및 유동특성을 고찰하였다. 특히 가스 누출 위치 주변의 장애물 배치가 밀폐 공간 내부의 가스 농도 분포에 미치는 영향을 분석하였으며, 메탄가스의 가연 한계 값을 이용하여 누출 특성을 정량적으로 비교하였다. 수치해석 결과, 분사류 주변으로 수직 벽면이 있을 경우, 장애물이 횡 방향 유동을 제한하여 종 방향 누출 거리가 장애물이 없을 경우에 비해 약 60% 가량 증가하였다. 하지만 Air filter가 가스 분사류 경로에 있을 경우, 횡 방향 누출 거리는 장애물이 없을 경우에 비해 최대 8배까지 증가하였다. 이러한 이유는 분사류가 수평 및 하부 방향으로 굴절되어 장애물 주변으로 재순환 유동이 형성되었기 때문이다. 따라서 밀폐공간 내 사고 방지 시스템 설계 시 주요 설비 위치 및 공간 구조가 누출 분사류 경로에 미치는 영향을 고려할 필요가 있다.

메탄 분류 화염에서의 연소 조건에 따른 NOx 배출 특성 (NOx Emission Characteristics in Parametrically Varied Methane-Air Coflow Flames)

  • 이상한;오창보;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제20회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.35-44
    • /
    • 2000
  • It was numerically studied that NOx emission characteristics of confined $CH_{4}$ jet flames with the variation of the diameter of inner fuel nozzle, the flow rate of $CH_{4}$ and equivalence ratio. Parabolic type equations were adopted in the calculation and GRI-2.1I mechanism was used for the chemical reaction. NOx emission index (EINOx) was introduced to evaluate NOx emission quantitatively in parametrically varied flames and the contribution of Thermal and Prompt NO mechanism was discussed. The results showed that Total EINOx varied sensitively with the variation of the flow rate of$CH_{4}$ but it was not sensitive to the variation of the diameter of inner fuel nozzle. Thermal EINOx showed the similar tendency to total EINOx and Prompt EINOx showed insensitivity to the variation of the diameter of inner fuel nozzle and the flow rate of $CH_{4}$.

  • PDF

Numerical Simulations of the Supersonic Jet Impingement in a Confined Plenum of Vertical Launching System

  • Lee Kwang-Seop;Lee Jin-Gyu;Hong Seung-Kyu;Ahan Chang-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.301-305
    • /
    • 2006
  • The Vertical Launching System design is especially complicated by complex flow structure in a plenum with the severe thermal state and high pressure load form the hot exhaust plume. The flow structures are numerically simulated by using the commercial code, CFD-FASTRAN with the axi-symmetrical Navier-Stokes equations. Two different cases are considered; that is, the stationary fire and the moving fire.

  • PDF

기체 유해물질 환기장치 설계를 위한 수치모사 (A Numerical Study for the Design of Ventilation System for the gaseous Pollutants)

  • 엄태인
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.77-84
    • /
    • 1994
  • A study is performed in order to design a effective ventilation equipment for the pollutants in workshop. The procedure has been used to calculate the flow in a confined rectangular space channel. A cross free stream is flowed from open space and jet stream including pollutants is injected from bottom area. Calculation results shows a wake region which exists immediarely downstream of the jet discharge and are compared with the experimental data. Calculation data are in good agreement with experimental results. A wake plays an important role on a stagnation of the pollutants. Thus ventilation equipment has to be designed without a stagnation region which give rise to concentration stratification. In this study, calculation parameters are the position and velocity of pollutants and fresh air from cross free stream. It is concluded that more measurements of local velocities, temperatures and concentrations of the pollutants.

  • PDF

정상초음파장의 위치에 따른 초음파 무화 케로신 부상화염의 거동 (A Behavior of the Ultrasonically-atomized Kerosene Lifted-flame According to the Position of Ultrasonic Standing-wave Field)

  • 배창한;김정수
    • 한국추진공학회지
    • /
    • 제27권1호
    • /
    • pp.1-8
    • /
    • 2023
  • 본 연구는 수송기체 유량 및 정상초음파장의 가진 위치에 따른 초음파 무화 케로신 화염의 거동을 분석하기 위해 수행되었다. Slit-jet 노즐을 빠져나오는 에어로졸의 연소장은 DSLR, ICCD 및 초고속 카메라와 슐리렌 기법을 통해 가시화되었으며, 연료소모량은 정밀저울을 통해 측정되었다. 그 결과, 정상초음파장 경계영역에서 화염이 갇히고, 정상초음파장의 위치가 높아질수록 연료소모량은 감소하였다.

산고래 온돌연도내의 유동분포에 관한 수치해석 (Numerical Analysis on the Flow Distribution in Ondol Flue Channel)

  • 민만기;이승우
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.264-274
    • /
    • 1983
  • Two-dimensional jet flows into a couple of confined rectangular enclosures such as an Ondol flue channel and their flow distributions were analyzed by numerical graphics : rectangular space in one enclosure is vacated and the other has 8 rectangular small posts. Both enclosures have a protruded inlet nozzle and on outlet on its center line. Steady state incompressible laminar viscous flow was assumed. The primitive forms of Navier-Stokes equations and continuity equation in a cartesian coordinate system were solved numerically by the Marker and Cell method for Reynolds numbers of 5, 10, 20, 30 and 40. From the numerical graphics it was found that the flow regions in both enclosures were devided into tow parts ; one part was the jet flow localized in a narrow center region of the enclosure and the other part was the very slow recirculating flow occupying the rest of the flow region in the enclosures. However there were a little differences in the shapes of jet flow in both enclosures for Reynolds numbers of 5 and 10 and also in the shapes of recirculating flows in both enclosures for all Reynolds number. Also it was found that waving flow appeared right before the outlet at Reynolds number of 20 and more.

  • PDF