• Title/Summary/Keyword: Confidence Evaluation

Search Result 787, Processing Time 0.029 seconds

Evaluation of Importance and Performance by Dietitians about Events Marketing at School Foodservice Operations in Busan (부산지역 학교급식 영양사의 이벤트 마케팅에 대한 중요도와 수행도 평가)

  • Lee, Kyung-A
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1794-1800
    • /
    • 2009
  • This research was performed to acquire dietitians' attitudes toward events marketing at school foodservice operations in the Busan area. A total of 359 questionnaires were distributed to dietitians employed at school foodservice operations in Busan from July 1 to 31, 2006 (response rate: 93%). All dietitians assessed the importance and performance of event marketing at 3.39/5.00 and 2.78/5.00. The elementary and high school had significantly (p<0.01) higher average scores of performance of event marketing than those of the middle school. The contract managed foodservices had significantly (p<0.01) higher average scores of performance of event marketing than those of the independent managed foodservices. In the Importance-Performance Analysis (IPA), high importance and high performance (B area: doing great) were seasonal event, traditional festival day event, subdivisions of the seasonal event, environment event, school event, the day event and high importance whereas low performance (A area: focus here) was health event. Event marketing increased customer satisfaction and confidence. Therefore, these results suggest that there may be a need to implement special events at school foodservice in order to increase students' satisfaction.

The Influence of the repeated learning of moving picture materials applying 'the development of mathematical power' program on The Self-Directed Learning (수학적 힘의 신장 프로그램을 적용한 교실 수업 동영상 자료 반복 학습이 자기 주도적 학습에 미치는 영향 - 수학 I 을 중심으로 -)

  • Byun Kyung-Hae
    • Communications of Mathematical Education
    • /
    • v.20 no.2 s.26
    • /
    • pp.295-326
    • /
    • 2006
  • Despite the importance of mathematics education, many students in high school have lost their interests and felt difficulties and they don't have 'mathematical' experience with meanings attached because of the entrance examination. This paper attempted to resolve these problems and find the teaching-method with which students can study by themselves with more confidence. Nowadays students' use of Internet is very popular. After develop 'the development of mathematical power' program based on mathematics history, history, science, the application of problems in real world, and self-evaluation, I made students repeat them after making teaching lessons in classroom as moving pictures. Through this processes, I attempted to develop the Self-Directed Learning' ability by making public education substantial. First of all I analyzed the actual conditions on 'Self-Directed Learning' ability in mathematics subject, the conditions of seeing and hearing in Internet learning program, and students' and their parents' interests in Internet education. By analyzing the records, I observed the significance of the introducing mathematics history in mathematics subject in early stager, cooperative-learning, leveled-learning, self-directed learning, and Internet learning. Actually in aspect of applying 'the development of mathematical power' program, at first I made up the educational conditions to fix the program, collected the teaching materials, established the system of teaching-learning model, developed materials for the learning applying Internet mail and instruments of classroom, and carried out instruction to establish and practice mathematics learning plan. Then I applied the teaching-learning model of leveled cooperation and presentation loaming and at the same time constructed and used the leveled learning materials of complementary, average, and advanced process and instructed to watch teaching moving pictures through Internet mail and in the classroom. After that I observed how effective this program was through the interest arid attitude toward mathematics subject, learning accomplishment, and the change of self-directed learning. Finally, I wrote the conclusion and suggestion on the preparation of conditions fur the students' voluntary participation in mathematics learning and the project and application on 'the development of mathematical power' program and repeated learning with the materials of moving pictures in classroom.

  • PDF

Comparison of C-reactive Protein between Capillary and Venous Blood in Children (소아에 있어서 C-반응성 단백의 모세혈 및 정맥혈 검사의 비교평가)

  • Jin, Ji Hoon;Jung, Soo Ho;Hong, Young Jin;Son, Byong Kwan;Kim, Soon Ki
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • Purpose : In evaluation of patients, laboratory results are crucial in determination of a treatment plan. Obtaining venous blood from infants and children is a difficult procedure. Substitution of a capillary blood sample for a venous blood sample has been suggested. However, there are few studies showing mutual correlation between C-reactive protein (CRP) results in capillary and venous blood. This study was designed to determine whether the result of the capillary sample is the same as the result of the venous blood sample. Methods : After informed consent, a pair of venous and fingertip capillary blood samples were simultaneously collected from 100 children. The LC-178CRPTM was used for analysis of capillary blood and the Hitachi 7180 automatic hematology analyzer was used for analysis of venous blood. We compared CRP of both venous and capillary blood samples. Results were analyzed by crosstabulation analysis, simple regression analysis and the Bland Altman Plot method. Results : A close correlation (90.63%) was observed between capillary and venous blood analyzed by crosstabulation analysis. CRP results were similar between the two groups and showed a high coefficient correlation ($\beta$=1.3434, $R^2$=0.9888, P<0.0001) when analyzed by a simple regression model. The average value in venous blood was also higher compared to capillary blood. According to Bland Altman Plot analysis, lab results were measured at a 95% confidence interval. Conclusion : CRP results from capillary blood showed close correlation with venous blood sampling. At present, venous blood sampling is the preferred method. However, due to difficulty in venous blood sampling, capillary sampling could be considered as an alternative technique for use with children.

Evaluation of the Measurement Uncertainty from the Standard Operating Procedures(SOP) of the National Environmental Specimen Bank (국가환경시료은행 생태계 대표시료의 채취 및 분석 표준운영절차에 대한 단계별 측정불확도 평가 연구)

  • Lee, Jongchun;Lee, Jangho;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Kim, Taekyu;Han, Areum;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.6
    • /
    • pp.607-618
    • /
    • 2015
  • Five years have passed since the first set of environmental samples was taken in 2011 to represent various ecosystems which would help future generations lead back to the past environment. Those samples have been preserved cryogenically in the National Environmental Specimen Bank(NESB) at the National Institute of Environmental Research. Even though there is a strict regulation (SOP, standard operating procedure) that rules over the whole sampling procedure to ensure each sample to represent the sampling area, it has not been put to the test for the validation. The question needs to be answered to clear any doubts on the representativeness and the quality of the samples. In order to address the question and ensure the sampling practice set in the SOP, many steps to the measurement of the sample, that is, from sampling in the field and the chemical analysis in the lab are broken down to evaluate the uncertainty at each level. Of the 8 species currently taken for the cryogenic preservation in the NESB, pine tree samples from two different sites were selected for this study. Duplicate samples were taken from each site according to the sampling protocol followed by the duplicate analyses which were carried out for each discrete sample. The uncertainties were evaluated by Robust ANOVA; two levels of uncertainty, one is the uncertainty from the sampling practice, and the other from the analytical process, were then compiled to give the measurement uncertainty on a measured concentration of the measurand. As a result, it was confirmed that it is the sampling practice not the analytical process that accounts for the most of the measurement uncertainty. Based on the top-down approach for the measurement uncertainty, the efficient way to ensure the representativeness of the sample was to increase the quantity of each discrete sample for the making of a composite sample, than to increase the number of the discrete samples across the site. Furthermore, the cost-effective approach to enhance the confidence level on the measurement can be expected from the efforts to lower the sampling uncertainty, not the analytical uncertainty. To test the representativeness of a composite sample of a sampling area, the variance within the site should be less than the difference from duplicate sampling. For that, a criterion, ${i.e.s^2}_{geochem}$(across the site variance) <${s^2}_{samp}$(variance at the sampling location) was proposed. In light of the criterion, the two representative samples for the two study areas passed the requirement. In contrast, whenever the variance of among the sampling locations (i.e. across the site) is larger than the sampling variance, more sampling increments need to be added within the sampling area until the requirement for the representativeness is achieved.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets (돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가)

  • Song, In-Bae;Kim, Tae-Won;Lee, Hong-Gee;Kim, Myoung-Seok;Hwang, Youn-Hwan;Park, Byung-Kwon;Lim, Jong-Hwan;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome, a fourth generation cephalosporin, has been solely used for veterinary medicine and has a broad antibacterial spectrum against gram-negatives and gram-positives being very stable to ${\beta}$-lactamases. This study was conducted to evaluate the bioequivalence of two cefquinome 2.5% products in piglets. Plasma cefquinome concentrations were analyzed by liquid chromatography-mass spectrometry (LC/MS). Mean maximum concentration ($C_{max}$) of test product ($Cequus^{(R)}$) and reference product ($Cobactan^{(R)}$) were $4.34{\pm}0.58$ and $4.22{\pm}0.47{\mu}g/mL$, and mean area under the concentration time curve ($AUC_{0{\rightarrow}{\infty}}$) values were $10.43{\pm}1.96$ and $10.25{\pm}2.98{\mu}g{\cdot}h/mL$, respectively. The 90% confidence intervals for the ratio of $C_{max}$ (0.941-1.115), and $AUC_{0{\rightarrow}{\infty}}$ (0.927-1.172) values for the test and reference products were within the acceptable bioequivalence limit of 0.80-1.25. It is concluded that two commercial cefquinome injectable solutions are bioequivalent in their extent of drug absorption in piglets.

Comparison of Gefitinib and Erlotinib for Patients with Advanced Non-Small-Cell Lung Cancer (진행성 비소세포폐암 환자에서 Gefitinib와 Erlotinib의 비교)

  • Lee, Jin Hwa;Lee, Kyoung Eun;Ryu, Yon Ju;Chun, Eun Mi;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.280-287
    • /
    • 2009
  • Background: The epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs), became an attractive therapeutic option for advanced non-small-cell lung cancer (NSCLC). Several studies suggested that there might be some different efficacy or response predictors between gefitinib and erlotinib. We compared the efficacy and toxicity of gefitinib and erlotinib in Korean patients with advanced NSCLC and evaluated specific predictors of response for both gefitinib and erlotinib. Methods: We collected the clinical information on patients with advanced NSCLC, who were treated with gefitinib or erlotinib at the Ewha Womans University Hospital, between July 2003 and February 2009. Median survival times were calculated using the Kaplan-Meier method. Results: Eighty-six patients (52 gefitinib vs. 34 erlotinib) were enrolled. Patient median age was 64 years; 53 (62%) subjects were male. Out of the 86 patients treated, 83 received response evaluation. Of the 83 patients, 35 achieved a response and 12 experienced stable disease while 36 experienced progressive disease, resulting in a response rate of 42% and a disease control rate of 57%. After a median follow-up of 502 days, the median progression-free and overall survival time was 129 and 259 days, respectively. Comparing patients by treatment (gefitinib vs erlotinib), there were no significant differences in the overall response rate (44% vs. 39%, p=0.678), median survival time (301 days vs. 202 days, p=0.151), or time to progression (136 days vs. 92 days, p=0.672). Both EGFR-TKIs showed similar toxicity. In a multivariate analysis using Cox regression model, adenocarcinoma was an independent predictor of survival (p=0.006; hazard ratio [HR], 0.487; 95% confidence interval [CI], 0.292-0.811). Analyses of subgroups did not show any difference in response predictors between gefitinib and erlotinib. Conclusion: Comparing gefitinib to erlotinib, there were no differences in the response rate, overall survival, progression-free survival, or toxicity. No specific predictor of response to each EGFR-TKI was identified.

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

THE EVALUATION OF PERIODONTAL LIGAMENT CELLS OF RAT TEETH AFTER LOW-TEMPERATURE PRESERVATION UNDER HIGH PRESSURE (고압-저온 보관에 따른 쥐 치아 치주인대세포의 활성도 평가)

  • Chung, Jin-Ho;Kim, Jin;Choi, Seong-Ho;Kim, Eui-Seong;Park, Ji-Yong;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.285-294
    • /
    • 2010
  • The purpose of this study was to evaluate the viability of periodontal ligament cells of rat teeth after low-temperature preservation under high pressure by means of MTT assay, WST-1 assay. 12 teeth of Sprague-Dawley white female rats of 4 week-old were used for each group. Both side of the first and second maxillary molars were extracted as atraumatically as possible under tiletamine anesthesia. The experimental groups were group 1 (Immediate extraction), group 2 (Slow freezing under pressure of 3 MPa), group 3 (Slow freezing under pressure of 2 MPa), group 4 (Slow freezing under no additional pressure), group 5 (Rapid freezing in liquid nitrogen under pressure of 2 MPa), group 6 (Rapid freezing in liquid nitrogen under no additional pressure), group 7 (low-temperature preservation at $0^{\circ}C$ under pressure of 2 MPa), group 8 (low-temperature preservation at $0^{\circ}C$ under no additional pressure), group 9 (low-temperature preservation at $-5^{\circ}C$ under pressure of 90 MPa). F-medium and 10% DMSO were used as preservation medium and cryo-protectant. For cryo-preservation groups, thawing was performed in $37^{\circ}C$ water bath, then MTT assay, WST-1 assay were processed. One way ANOVA and Tukey HSD method were performed at the 95% level of confidence. The values of optical density obtained by MTT assay and WST-1 were divided by the values of eosin staining for tissue volume standardization. In both MTT and WST-1 assay, group 7 ($0^{\circ}C$/2 MPa) showed higher viability of periodontal ligament cells than other group (2-6, 8) and this was statistically significant (p < 0.05), but showed lower viability than group 1, immediate extraction group (no statistical significance). By the results of this study, low-temperature preservation at $0^{\circ}C$ under pressure of 2 MPa suggest the possibility for long term preservation of teeth.

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF