• Title/Summary/Keyword: Cone-beam computed tomography(CBCT)

Search Result 556, Processing Time 0.024 seconds

Alveolar bone thickness and lower incisor position in skeletal Class I and Class II malocclusions assessed with cone-beam computed tomography

  • Baysal, Asli;Ucar, Faruk Izzet;Buyuk, Suleyman Kutalmis;Ozer, Torun;Uysal, Tancan
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.134-140
    • /
    • 2013
  • Objective: To evaluate lower incisor position and bony support between patients with Class II average- and high-angle malocclusions and compare with the patients presenting Class I malocclusions. Methods: CBCT records of 79 patients were divided into 2 groups according to sagittal jaw relationships: Class I and II. Each group was further divided into average- and high-angle subgroups. Six angular and 6 linear measurements were performed. Independent samples t-test, Kruskal-Wallis, and Dunn post-hoc tests were performed for statistical comparisons. Results: Labial alveolar bone thickness was significantly higher in Class I group compared to Class II group (p = 0.003). Lingual alveolar bone angle (p = 0.004), lower incisor protrusion (p = 0.007) and proclination (p = 0.046) were greatest in Class II average-angle patients. Spongious bone was thinner (p = 0.016) and root apex was closer to the labial cortex in high-angle subgroups when compared to the Class II average-angle subgroup (p = 0.004). Conclusions: Mandibular anterior bony support and lower incisor position were different between average- and high-angle Class II patients. Clinicians should be aware that the range of lower incisor movement in high-angle Class II patients is limited compared to average- angle Class II patients.

Adenomatoid Odontogenic Tumor in the Posterior Mandible of a Young Child : A Case Report (하악 유구치부에서 발생한 선양 치성 종양의 증례 보고)

  • Sim, Dohee;Mah, Yonjoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.87-92
    • /
    • 2020
  • Adenomatoid odontogenic tumor (AOT) is a rare benign odontogenic jaw lesion. It usually occurs in the anterior maxilla and is mostly related to impacted canines in teenagers. A 3-year-old girl was referred from a local dental clinic due to delayed eruption of the right primary mandibular 2nd molar. There was no history of pain or swelling. Radiography revealed a large radiolucency lesion with radiopacities around the unerupted right primary mandibular 2nd molar. Surgical enucleation with extraction of the right primary mandibular 2nd molar and surgical biopsy were performed. Based on the clinical and radiological findings, this lesion was defined as an ameloblastic fibro-odontoma which often develops in the mandible of adolescents. However, this lesion was diagnosed as AOT from the results of the histological examination. This report aimed to present a rare case of AOT in the posterior mandibular area in a very young patient.

Qualitative correlation between postoperatively increased vertical dimension and mandibular position in skeletal class III using partial-least-square path modeling

  • Kim, Na-Ri;Park, Soo-Byung;Lee, Jihyun;Choi, Youn-Kyung;Shin, Sang Min;Choi, Yong-Seok;Kim, Yong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.15.1-15.7
    • /
    • 2017
  • Background: This study constructed a partial-least-square path-modeling (PLS-PM) model and found the pathway by which the postsurgical vertical dimension (VD) affects the extent of the final mandibular setback on the B point at the posttreatment stage for the skeletal class III surgery-first approach (SFA). Methods: This study re-analyzed the data from the retrospective study by Lee et al. on 40 patients with skeletal class III bimaxillary SFA. Variables were obtained from cone beam computed tomography (CBCT)-generated cephalograms. Authors investigated all variables at each time point to build a PLS-PM model to verify the effect of the VD on the final setback of the mandible. Results: From PLS-PM, an increase in $VD_{10}$ was found to decrease the absolute value of the final setback amount of the mandible, which reflects the postsurgical physiological responses to both surgery and orthodontic treatment, which, in turn, can be interpreted as an increase in postoperative mandibular changes. Conclusions: To resolve the issue of collinear cephalometric data, the present study adopted PLS-PM to assess the orthodontic treatment. From PLS-PM, it was able to summarize the effect of increased postsurgery occlusal vertical dimension on the increased changeability of the B point position at the posttreatment stage.

Shape and anatomical relationship of the mental foramen to the mandibular premolars in an Indian sub-population: a retrospective CBCT analysis

  • Komal Sheth;Kulvinder Singh Banga;Ajinkya M. Pawar;James L. Gutmann;Hyeon-Cheol Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.1.1-1.13
    • /
    • 2022
  • Objectives: This study assessed the shape and anatomical relationship of the mental foramen (MF) to mandibular posterior teeth in an Indian sub-population. Materials and Methods: In total, 475 existing cone-beam computed tomography records exhibiting 950 MFs and including the bilateral presence of mandibular premolars and first molars were assessed. Images were evaluated 3-dimensionally to ascertain the position, shape, and anatomical proximity of MFs to mandibular teeth. The position and shape of MFs were measured and calculated. The Pythagorean theorem was used to calculate the distance between the root apex of the mandibular teeth and the MF. Results: MFs exhibited a predominantly round shape (left: 67% and right: 65%) followed by oval (left: 30% and right: 31%) in both males and females and in different age groups. The root apices of mandibular second premolars (left: 71% and right: 62%) were closest to the MF, followed by distal to the first premolars and mesial to the second premolars. The mean vertical distance between the MF and the nearest tooth apex calculated on sagittal sections was 2.20 mm on the right side and 2.32 mm on the left side; no significant difference was found according to sex or age. The distance between the apices of the teeth and the MF was ≥ 4 mm (left; 4.09 ± 1.27 mm and right; 4.01 ± 1.15 mm). Conclusions: These findings highlight the need for clinicians to be aware of the location of the MF in treatment planning and while performing non-surgical and surgical endodontic procedures.

Early implant placement in sites with ridge preservation or spontaneous healing: histologic, profilometric, and CBCT analyses of an exploratory RCT

  • Stefan P. Bienz;Edwin Ruales-Carrera;Wan-Zhen Lee;Christoph H. F. Hammerle;Ronald E. Jung;Daniel S. Thoma
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.108-121
    • /
    • 2024
  • Purpose: The aim of this study was to compare changes in soft and hard tissue and the histologic composition following early implant placement in sites with alveolar ridge preservation or spontaneous healing (SH), as well as implant performance up to 1 year after crown insertion. Methods: Thirty-five patients with either intact buccal bone plates or dehiscence of up to 50% following single-tooth extraction of incisors, canines, or premolars were included in the study. They were randomly assigned to undergo one of three procedures: deproteinized bovine bone mineral with 10% collagen (DBBM-C) covered by a collagen matrix (DBBM-C/CM), DBBM-C alone, or SH. At 8 weeks, implant placement was carried out, and cone-beam computed tomography scans and impressions were obtained for profilometric analysis. Patients were followed up after the final crown insertion and again at 1 year post-procedure. Results: Within the first 8 weeks following tooth extraction, the median height of the buccal soft tissue contour changed by -2.11 mm for the DBBM-C/CM group, -1.62 mm for the DBBM-C group, and -1.93 mm for the SH group. The corresponding height of the buccal mineralized tissue changed by -0.27 mm for the DBBM-C/CM group, -2.73 mm for the DBBM-C group, and -1.48 mm for the SH group. The median contour changes between crown insertion and 1 year were -0.19 mm in the DBBM-C/CM group, -0.09 mm in the DBBM-C group, and -0.29 mm in the SH group. Conclusions: Major vertical and horizontal ridge contour changes occurred, irrespective of the treatment modality, up to 8 weeks following tooth extraction. The DBBM-C/CM preserved more mineralized tissue throughout this period, despite a substantial reduction in the overall contour. All 3 protocols led to stable tissues for up to 1 year.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

A study on Radix Entomolaris about prevalence and correlation of canal orifices location according to number of roots in mandibular first molars (하악 제1대구치에서 Radix Entomolaris의 발현빈도와 치근의 개수에 따른 근관 입구들 사이의 위치 관계에 대한 연구)

  • Jang, Ji-Hye;Kim, Jin-Woo;Cho, Kyung-Mo;Kim, Soo-Yeon;Park, Se-Hee
    • The Journal of the Korean dental association
    • /
    • v.56 no.12
    • /
    • pp.695-706
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the ratio of 4 root canals and the incidence of Radix Entomolaris in mandibular first molars and find out anatomical difference according to number of roots by analysis of cone-beam CT images in a Korean population. Materials and Methods: Total 142 images containing mandibular first molars were selected from CBCT images taken from 2013 to 2017 at Gangneung-Wonju National University Dental Hospital. After reconstructing the image with reference to the Cemento-enamel junction, the root canals were detected at the bottom of the pulpal floor and the number of roots and root canals were analyzed. Various lengths and MLO-DLO-DBO angle were measured between each canal orifices and the external contour line of the tooth, and the distolingual canal wall thickness was measured. Student t-test was used for statistical significance. Results: Among the total 142 teeth, 4 canals were 42.2% and Radix Entomolaris was 25.3%. As the results of measuring various lengths and the angle, the distolingual canal orifice in Group 2(with Radix Entomolaris) tends to deviate to the lingual side than the mesiolingual canal orifice and to the mesial side than the distobuccal canal orifice. Besides, thickness of the distolingual canal wall in Group 2(with Radix Entomolaris) was significantly thinner than that of Group 1 at every level except pulpal floor level. Conclusion: It is necessary to consider the difference according to the presence of Radix Entomolaris in endodontic treatment.

  • PDF

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

Gaussian Noise Reduction Method using Adaptive Total Variation : Application to Cone-Beam Computed Tomography Dental Image (적응형 총변이 기법을 이용한 가우시안 잡음 제거 방법: CBCT 치과 영상에 적용)

  • Kim, Joong-Hyuk;Kim, Jung-Chae;Kim, Kee-Deog;Yoo, Sun-K.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.29-38
    • /
    • 2012
  • The noise generated in the process of obtaining the medical image acts as the element obstructing the image interpretation and diagnosis. To restore the true image from the image polluted from the noise, the total variation optimization algorithm was proposed by the R.O. F (L.Rudin, S Osher, E. Fatemi). This method removes the noise by fitting the balance of the regularity and fidelity. However, the blurring phenomenon of the border area generated in the process of performing the iterative operation cannot be avoided. In this paper, we propose the adaptive total variation method by mapping the control parameter to the proposed transfer function for minimizing boundary error. The proposed transfer function is determined by the noise variance and the local property of the image. The proposed method was applied to 464 tooth images. To evaluate proposed method performance, PSNR which is a indicator of signal and noise's signal power ratio was used. The experimental results show that the proposed method has better performance than other methods.