• Title/Summary/Keyword: Cone-Beam Computed

Search Result 827, Processing Time 0.047 seconds

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Evaluation of the mechanical properties and clinical efficacy of biphasic calcium phosphate-added collagen membrane in ridge preservation

  • Lee, Jung-Tae;Lee, Yoonsub;Lee, Dajung;Choi, Yusang;Park, Jinyoung;Kim, Sungtae
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.238-250
    • /
    • 2020
  • Purpose: This study aimed to evaluate the biocompatibility and the mechanical properties of ultraviolet (UV) cross-linked and biphasic calcium phosphate (BCP)-added collagen membranes and to compare the clinical results of ridge preservation to those obtained using chemically cross-linked collagen membranes. Methods: The study comprised an in vitro test and a clinical trial for membrane evaluation. BCP-added collagen membranes with UV cross-linking were prepared. In the in vitro test, scanning electron microscopy, a collagenase assay, and a tensile strength test were performed. The clinical trial involved 14 patients undergoing a ridge preservation procedure. All participants were randomly divided into the test group, which received UV cross-linked membranes (n=7), and the control group, which received chemically cross-linked membranes (n=7). BCP bone substitutes were used for both the test group and the control group. Cone-beam computed tomography (CBCT) scans were performed and alginate impressions were taken 1 week and 3 months after surgery. The casts were scanned via an optical scanner to measure the volumetric changes. The results were analyzed using the nonparametric Mann-Whitney U test. Results: The fastest degradation rate was found in the collagen membranes without the addition of BCP. The highest enzyme resistance and the highest tensile strength were found when the collagen-to-BCP ratio was 1:1. There was no significant difference in dimensional changes in the 3-dimensional modeling or CBCT scans between the test and control groups in the clinical trial (P>0.05). Conclusions: The addition of BCP and UV cross-linking improved the biocompatibility and the mechanical strength of the membranes. Within the limits of the clinical trial, the sites grafted using BCP in combination with UV cross-linked and BCP-added collagen membranes (test group) did not show any statistically significant difference in terms of dimensional change compared with the control group.

Anatomical Characteristics of the Mandibular Median Lingual Foramen: the Assessment of the CBCT (CBCT를 이용한 하악 정중설공의 해부학적 평가)

  • Lee, Go-Woon;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.337-346
    • /
    • 2013
  • It is necessary to consider the median lingual foramen carefully to prevent the bleeding due to the damage of the sublingual artery for implant surgery. This study is to evaluate the frequency, location, diameter and the number of the Mandibular median lingual foramen regarding gender and age in the CBCT. Sixty two images of cone beam computed tomography (CBCT) whose visited the Chonnam National University Dental hospital from Sept. 2010 to Apr. 2011 were evaluated. Frequency, number, location and the diameter of Mandibular median lingual foramen shown in the CBCT image were evaluated. Sixty two patients (100%) had at least one median lingual foramen and fifty six patients (90.32%) had multiple foramens. Forty patients (66.13%) showed the median lingual foramen on the location between Mn. central incisors. The mean vertical position of the genial spine and the median lingual foramen was 24.21 mm and 14.52 mm, respectively. And the relative mean vertical dimension of median lingual foramen was 0.45. The mean diameter of the foramen was 0.93 mm. CBCT demonstrated the frequency, location, diameter and the number of median lingual foramen. It is necessary to take CBCT before implant placement to prevent the bleeding.

The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy (방사선치료 시 자세확인시스템이 처방선량에 미치는 영향)

  • Kim, Jeong-Ho;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.613-620
    • /
    • 2017
  • Planning dose must be delivered accurately for radiation therapy. Also, It must be needed accurately setup. However, patient positioning images were need for accuracy setup. Then patient positioning images is followed by additional exposure to radiation. For 45 points in the phantom, we measured the doses for 6 MV and 10 MV photon beams, OBI(On Board Imager) and CBCT(Conebeam Computed Tomography) using OSLD(Optically Stimulated Luminescent Dosimeter). We compared the differences in the cases where posture confirmation imaging at each point was added to the treatment dose. Also, we tried to propose a photography cycle that satisfies the 5% recommended by AAPM(The American Association of Physicists in Medicine). As a result, a maximum of 98.6 cGy was obtained at a minimum of 45.27 cGy at the 6 MV, a maximum of 99.66 cGy at a minimum of 53.34 cGy at the 10 MV, a maximum of 2.64 cGy at the minimum of 0.19 cGy for the OBI and a maximum of 17.18 cGy at the minimum of 0.54 cGy for the CBCT.The ratio of the radiation dose to the treatment dose is 3.49% in the case of 2D imaging and the maximum is 22.65% in the case of 3D imaging. Therefore, tolerance of 2D image is 1 exposure per day, and 3D image is 1 exposure per week. And it is need to calculation of separate in the parallelism at additional study.

Assessment of Midpalatal Suture Maturation by Skeletal Maturity on Hand Wrist Radiographs (성장기 아동의 수완부 골 성숙도를 이용한 정중구개봉합 성숙도 평가)

  • Yu, Dayeol;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.31-41
    • /
    • 2021
  • The aim of this retrospective study was to evaluate the correlation between the midpalatal suture maturation and skeletal maturation in growing children aged 7 - 15 years and predict the maturational stages of the midpalatal suture corresponding to skeletal maturity assessed by the skeletal maturation indicators (SMI) and middle phalanx of the third finger (MP3) stages. The group of this retrospective study was consisted of randomly selected 132 male and 135 female in age from 7 - 15 years. The maturation of the midpalatal suture was evaluated by using images from cone-beam computed tomography (CBCT) while the skeletal age was assessed by hand-wrist radiography. CBCT images and hand-wrist radiographs used in this study were obtained from all subjects for orthodontic diagnosis before orthodontic treatment. The maturational stages of the midpalatal suture showed strong correlations with both SMI and MP3 stages. The correlation between the midpalatal suture maturation and SMI (Spearman's correlation coefficient, ϒS = 0.905, p < 0.05) was slightly greater than that of MP3 stages (ϒS = 0.830, p < 0.05). There was a positive significant correlation between the midpalatal suture maturation and chronological age (ϒS = 0.868,p < 0.05). CBCT for evaluation of the midpalatal suture maturational stages may be unnecessary in every pediatric patients because SMI and MP3 stages were both replaceable useful methods for assessing maturation of the midpalatal suture before orthopedic treatment. In this retrospective study, the diagnostic reliability of the SMI method for estimating midpalatal suture maturation showed better reliability than the MP3 method.

Frequency of Buccal Pits and Defective Buccal Pits in Mandibular Molars of Children and Adolescents (소아청소년의 하악 대구치에서 협측소와 및 협측소와 결함의 발생 빈도)

  • So Yung, Kim;Je Seon, Song;Ik-Hwan, Kim;Hyung-Jun, Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.253-263
    • /
    • 2022
  • A buccal pit is a prominent point-like depression that appears at the cervical end of the mandibular molar developmental grooves. A defective buccal pit can be defined as a buccal pit in which the continuity of the dentinoenamel junction is broken and the pit extends to the dentinal level. This study aimed to determine the frequency of buccal pits and defective buccal pits in un-erupted mandibular first and second molars using cone-beam computed tomography (CBCT). The analysis was performed on CBCT images taken from 417 Korean children and adolescents who visited the Department of Pediatric Dentistry, Yonsei University Dental Hospital between 2004 and 2020. Based on cross-sectional views of CBCT images, buccal pits were categorized into 4 classes according to the depth of the pits. The expression rate of the buccal pits was 29.1%. The prevalence of defective buccal pits was 7.9%. The buccal pits tended to develop bilaterally. To date, this is the most comprehensive study on the frequency of buccal pits with the largest sample size. This was the first attempt worldwide to analyze the depth of the buccal pit using CBCT images and to define a defective buccal pit worldwide.

Analysis of the Characteristics of Maxillary Supernumerary Lateral Incisor (상악 측절치 과잉치의 특징 분석)

  • Nah, Jeungseon;Lee, Koeun;Kim, Misun;Nam, Okhyung;Choi, Sungchul;Lee, Hyo-Seol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • This study aimed to investigate a quantitative analysis of the anatomical characteristics of the maxillary supernumerary lateral incisor and its relationship with lateral incisors. Forty-four supernumerary lateral incisors from 43 patients were evaluated for analyzing the position, shape, direction, and relationship between the supernumerary lateral incisor and the normal lateral incisors, using cone-beam computed tomography (CBCT). To compare the size of crown, the mesio-distal width was measured and the Nolla stage was used for evaluating the degree of root development to compare tooth maturity. The supernumerary lateral incisors were in the normal direction at a rate of 90.9%, and in a supplemental shape at a rate of 84.1%. The supernumerary lateral incisor was smaller in size compared to the adjacent lateral incisor and opposite lateral incisor (p < .0001). There was no statistically significant difference in the development stage of root. Based on these results, the supernumerary lateral incisor is similar with the lateral incisor, but has a difference in the size of crown. It is necessary to distinguish the supernumerary lateral incisor from the lateral incisor precisely to reduce clinical complications.

Three Dimensional Skeletal, Dentoalveolar and Airway Space Changes after Slow Maxillary Expansion in Children (어린이에서 저속 상악 확장에 따른 골격성, 치아치조성, 기도 변화에 대한 3차원적 평가)

  • Nawoon Kim;Daewoo Lee;Jae-Gon Kim;Yeonmi Yang
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.155-167
    • /
    • 2023
  • The aim of this study was to investigate the effects of slow maxillary expansion (SME) on the dentoalveolar, skeletal, upper airway, and maxillary sinus using cone-beam computed tomography (CBCT). Twenty-three orthodontic patients (mean age 8.93 ± 1.61 years) who were treated with maxillary expansion using banded hyrax in the Department of Pediatric Dentistry at Jeonbuk National University Dental Hospital were included. According to the expansion speed applied, they were divided into two groups: SME (12 subjects, mean age 8.92 ± 1.45 years) and rapid maxillary expansion (RME, 11 subjects, mean age 8.94 ± 1.84 years). CBCT were obtained before (T0) and after (T1) the treatment and were analyzed with InVivo5 software (Anatomage, San Jose, CA, USA). Descriptive statistics showed no significant differences between the two groups in age, sex, or skeletal maturity. There were significant increases in maxillary width at the dentoalveolar and skeletal levels for both groups. Upper airway volume revealed a significant increase of 38.59% in the SME group and 28.72% in the RME group. However, there was no significant difference between SME group and RME group in all measurements. This study suggested the efficacy of SME in growing patients. SME was effective in increasing not only dentoalveolar and skeletal measurements but also airway volume. Therefore, pediatric dentists should select an appropriate expansion method considering the physiological aspects of periodontal tissues and discomfort in growing children.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

Effects of wax rim in image registration of intraoral and face scan in edentulous arch condition (무치악 악궁에서 구강과 안면 스캔의 정합을 위한 왁스림의 활용 효과)

  • Sang-Hyeok Seo;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.135-141
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of image merging of an intraoral scan of an edentulous arch to a facial scan using wax rim and markers. Materials and Methods: For registration of oral scan to face scan, a wax rim with markers was made. The markers were cuboid and divided into four groups according to size (5, 10 mm) and attachment location (midline, canine region). The evaluation of registration accuracy was compared with a standard created using cone-beam computed tomography data. Anterior linear variation of the edentulous arch and the 3D variation of the overall arch were measured. Kruskal-Wallis test and Mann-Whitney U test were used for statistics, and the significance level was set at 0.05 and evaluated under Bonferroni correction (0.05/6 = 0.083). Results: In the anterior deviation and global deviation results, there was no statistically significant difference in the oral scan position displacement values between the 5 mm and 10 mm groups. When the midline marker was used, the intraoral scan position displacement value was significantly lower than when only the canine marker was used. Conclusion: Marker attached wax rim can be used for image matching between facial and intraoral scans of the edentulous arch. Marker location at the middle area increases the accuracy of image matching.