• 제목/요약/키워드: Cone penetration point

검색결과 19건 처리시간 0.025초

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구 (Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil)

  • 손무락;이재용
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.5-15
    • /
    • 2016
  • 본 연구에서는 소형콘의 관입저항력을 이용한 점토의 액성한계를 측정하기 위하여 카올리나이트 점토와 벤토나이트 점토의 비율을 다양하게 혼합한 점토흙에 대하여 함수비와 소형콘의 관입저항력을 조사하고 기존의 동적(Casagrande 시험법) 및 정적(Fall cone 시험법) 액성한계 시험결과와 직접 비교하였다. 비교결과 다양한 점토흙의 함수비에 따른 관입저항력 관계곡선에서 변곡점이 형성된다는 것을 파악하였으며 이 때의 함수비가 정적액성한계(Fall cone)시험법에 의한 액성한계 값과 매우 유사함을 파악하였다. 변곡점이 형성된 점에서의 소형콘의 관입저항력은 약 0.2kPa로 나타났으며 이 때 의 함수비가 점토흙의 액성한계를 나타낸다는 것을 확인하였다. 이와 같은 연구결과를 토대로 향후 점토의 액성한계를 파악하는데 본 연구에서 조사된 0.2kPa의 소형콘의 관입저항력이 유용한 지표가 될 수 있다는 사실을 파악하였다. 또한 소형콘의 관입저항력을 이용한 액성한계 시험법을 제시하였다.

연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구 (Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground)

  • 원정윤;장병욱;우철웅;윤상묵
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

사질토 지반에서의 정적관입저항과 기준응력과의 관계 (The Relationship Between Static Cone Penetration Resistance and the Reference Stress in Sandy Soils)

  • 백세환;이명환;이원제
    • 한국지반공학회지:지반
    • /
    • 제6권4호
    • /
    • pp.33-42
    • /
    • 1990
  • 정적관입저항 또는 선단지지말뚝의 선단지지력을 해석함에 있어서는 유효수직응력이 기준음력으로 사용되어 왔다. 그러나 정적관입저항은 유효수직응력보다 원위치 유효수평응력에 관계된다는 것이 많은 실험연구결과로부터 보고 되었다. 이와같은 문제점을 규명하기 위하여 기 보고된 실험결과를 다시 분석하였으며 실험실에서의 관입시험이 실시되었다. 연구결과 정적관입저항은 유효수직 응력과 유효수평응력 모두에 영향을 받는 것으로 나타나고 있으며 해석시에는 평균주응력이 기준응력으로 사용되어야 함을 결론 지을 수 있었다.

  • PDF

폐윤활유를 이용한 아스팔트 실란트 (Asphalt Sealant Containing the Waste Lubricant Oil)

  • 김석준;고금진
    • Elastomers and Composites
    • /
    • 제44권1호
    • /
    • pp.69-75
    • /
    • 2009
  • 본 연구에서는 폐윤활유를 이용하여 아스팔트 포장도로의 균열 보수에 주로 사용하는 아스팔트 실란트를 제조하였다. 아스팔트(AP-5), SBS 삼블록 공중합체(triblock copolymer), 점착제(석유수지) 및 산화방지제를 폐윤활유와 혼합하여 콘 침입도, 연화점, 신도, 흐름성, 인장 접착 신율 및 원상회복률을 측정하였다. 폐윤활유 함량이 증가함에 따라 아스팔트 실란트의 콘 침입도는 증가하였고 연화점, 신도 및 원상회복률은 감소하였다. 증량제로 탈크를 첨가할 경우 함량에 비례하여 연화점 및 원상회복률은 증가하였으나 콘 침입도, 신도 및 인장 접착 신율은 감소하였다. 석유수지 함량을 크게 줄여 ASTM 규격에 적합하면서도 가장 경제적인 균열 보수용 아스팔트 실란트를 제조할 수 있었다.

Fall Cone Test의 일점법을 이용한 액성한계 추정 (Estimation of Liquid Limit by a Single-point Method of Fall Cone Test)

  • 손영환;장병욱;원정윤;김성필
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.203-206
    • /
    • 2003
  • The liquid limit(LL) test is universally used as a standard test for determining one of the index properties of a clay. There are two methods of determining the LL, Casagrande method and cone penetration method that is fall cone test. The interpretation of the Casagrande method of obtaining the LL is not obvious, but it has been suggested that the fall cone test is essentially a strength test and that the LL test simply ascertains the moisture content at which a clay has a certain standard undrained shear strength. This paper presents a determination of the LL by a single-point method. Results obtained from fall cone that is general method and a single-point method are analyzed by comparison.

  • PDF

동적 콘 관입지수를 이용한 철도노반의 전단파속도 추정 (Shear Wave Velocity Estimation of Railway Roadbed Using Dynamic Cone Penetration Index)

  • 홍원택;변용훈;최찬용;이종섭
    • 한국지반공학회논문집
    • /
    • 제31권11호
    • /
    • pp.25-31
    • /
    • 2015
  • 연속 동하중을 지지하는 철도노반의 탄성거동은 대상 상부노반의 전단탄성계수에 주된 영향을 받으므로, 일정한 다짐도로 조성된 상부노반에서의 전단파속도 획득은 대상 지반의 탄성거동 예측에 활용될 수 있다. 본 연구에서는 상부노반에서 수행된 동적 콘 관입시험(DCPT) 결과로부터 전단파속도($V_s$)를 추정하기 위하여 동적 콘 관입지수(DCPI)와 전단파속도의 상호관계를 제시하고자 하였다. 상호관계의 신뢰도를 확보하기 위하여 동적 콘 관입시험 및 전단파속도 획득은 시공 완료된 철도 상부노반에서 수행되었다. 전단파속도 획득 방법으로서 cross hole 방법이 사용되었으며, 수신기와 발신기의 중간 위치에서 동적 콘 관입시험이 수행되었다. 동일한 심도에서의 동적 콘 관입지수 및 전단파속도 비교 결과, 전단파속도는 결정계수가 0.8 이상인 동적 콘 관입지수의 거듭제곱 형태로 나타났다. 본 연구결과는 동적 콘 관입기를 이용한 상부노반의 강도평가와 동시에 전단파속도 추정 방법으로써 유용하게 사용될 것이라 기대된다.

피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구 (A Study on the Determination of Depth of Soft Ground by Cone Resistance)

  • 신윤섭;김민철;김연정;김영웅
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 김연정;김남호;신윤섭
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.261-269
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과(N치), 선행압밀하중(pc), 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 $q_c$=(1.09~1.63)N, 선행압밀하중을 고려한 결과 $q_c$=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 10kgf/$cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 65~70.0kgf/$cm^2$의 값을 나타내였다.

  • PDF

WIM 센서 설치에 적합한 실런트 개발을 위한 기초적인 연구 (Fundamental Study on Development of Sealants used for WIM Sensor Installation)

  • 임치수;김두병;김용주;이강훈;이재준
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.17-24
    • /
    • 2017
  • PURPOSES : This study aims to develop a sealant for use in the installation of Weigh-In-Motion (WIM) sensor for asphalt concrete or cement concrete pavements. METHODS : In order to investigate the properties of various sealants that were mixed with latex and carbon fiber, various test methods were adopted, such as bituminous bond strength test, softening point test, and cone penetration test. To evaluate moisture susceptibility, the BBS test was conducted under moist condition. The bond strength ratio (BSR) was calculated based on tensile strength ratio method. RESULTS : The sealant's properties significantly varied according to the amount of latex or carbon fiber. The usage of latex marginally enhanced the cone penetration test result, notwithstanding reduced asphalt content. This implies that the sealant will be proper cold temperature reason. Moreover, the addition of latex and carbon fiber evidently increased the softening point. This indicates that the tendency of the material to flow at elevated temperatures is encountered during service. With the addition of latex and carbon fiber, the moisture susceptibility measured with BSR improved marginally, while the bond strength under dry condition decreased marginally. Sealant F displays the highest bond strength and BSR under limited test conditions. CONCLUSIONS : According to the proportion of latex and carbon fiber mixed, properties of sealant, such as softening point, cone penetration, and BSR varied marginally. This indicates that the sealant has to be applied considering the environmental condition, to improve service life.