• Title/Summary/Keyword: Conductor Loss

Search Result 219, Processing Time 0.035 seconds

Transport current loss of YBCO Coated Conductor and Bi-2223 tape (Bi-2223 선재와 YBCO Coated Conductor 선재의 전송전류 손실 비교)

  • Lim Hyoungwoo;Lee Kwangyoun;Cha Gueesoo;Lee Jikwang;Park Chan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1010-1012
    • /
    • 2004
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we measured and compared characteristics of BSCCO tape and YBCO Coated Conductor(YBCO CC). BSCCO tape was fabricated by PIT method. We measured critical current density and transport current loss of it. Also, YBCO CC tape consist of substrate. buffer, YBCO and metal layers. We measured critical current density on variations of external magnetic field and transport current loss of these cases. The results of measurement show that normalized critical current of YBCO CC is smaller then that of BSCCO tape in the external magnet field. According to the results. measured loss and calculated of the YBCO CC show the same tendency.

  • PDF

Transport Loss Characteristic of the Bifilar Pancake Type Fault Current Limiting Coil using Coated Conductor (Coated Conductor를 사용한 무유도 팬케이크형 한류 코일의 통전 손실 특성)

  • Park, Dong-Keun;Bang, Joo-Seok;Yang, Seong-Eun;Ahn, Min-Cheol;Sim, Ki-Deok;Yoon, Yong-Soo;Nam, Kwan-Woo;Seok, Bok-Yeol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.21-25
    • /
    • 2007
  • Superconducting fault current limiter (SFCL) is attractive apparatus to reduce fault current in power grid. Since it is applied to the alternating current (AC) power line, the SFCL has losses in the normal operation. Recently, coated conductor (CC) is noticeable material employed for resistive bifilar winding type SFCL in many research groups. Bifilar structure is expected to have low AC loss by magnetic field offset as compared with the single tape structure in the same length. This paper reports about characteristic of bifilar pancake type coil for SFCL application in AC loss aspect. The bifilar coil is wound using CC with facing on HTS sides each other. Transport AC loss measurement and characteristic analysis of the bifilar coil using CC have been performed at 77K. The test results are compared with the Norris equations and the test results of non-inductively wound paralleled solenoid type coil which is suggested and tested in this group at present.

Measurement of magnetization loss according to the winding pitch of CORC®

  • Han, Jinwoo;Choi, Kyeongdal;Kim, Woo-Seok;Lee, Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.25-29
    • /
    • 2021
  • For the application of HTS wire to AC power equipment, a conductor with high current capacity and low loss is required. CORC®, one of the high-current conductors manufactured using several HTS wires, is made by winding the wires in a spiral on a cylindrical former. Because the magnetization loss of a CORC® conductor depends on the degree of magnetic coupling between the wires constituting the CORC®, it is necessary to know the value of the magnetization loss of the CORC® itself. In order to obtain an accurate loss value, it is necessary to know the effect of the ratio of the winding pitch of the CORC® conductor in the pickup coil region sampling the magnetization loss signal. To confirm this effect, we prepare CORC® samples having various winding pitches, and measure and compare the magnetization losses. In addition, the magnetization loss was measured while rotating the CORC® samples and it was examined whether there was a difference in the magnetization loss according to the rotation.

Uniform Current Distribution among Conductor Layers in HTS Cables Using Inter-Phase Transformers (Inter-Phase Transformers를 이용한 고온 초전도 케이블의 층간 전류 등분배 방안)

  • 최용선;황시돌;현옥배;임성우;박인규
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.144-148
    • /
    • 2004
  • Uniform current distribution among conductor layers in HTS cables using IPTs (inter-phase transformers) was investigated. Conventional methods for current distribution, in which resistors are inserted to conductor layers, causes additional loss. In contrast, IPTs, which use magnetic coupling, make it possible that the current in parallel circuits is distributed uniformly with any load, and minimize the loss. In this study, IPTs were designed and fabricated for examination of uniform current distribution in the conductor layers of HTS cables. The ITP was designed through calculation of its impedance that can cancel the inductance of the conduction layers. The experimental setup consisted of four IPTs and four inductors that simulate the conductor layer inductance. Each layer was designed to feed 10 A. We examined the behavior of current distribution with IPTs for various layer inductances.

  • PDF

Heat Transfer Analysis and Cooling Design for Crude Oil Pump System (원유펌프시스템의 열전달해석 및 냉각설계)

  • Kim, Wan-Gi;Lee, Joon-Yeob;Kwon, Jung-Lock;Kim, Hea-Choen
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

Fabrication of coated conductor stacked multi-filamentary wire (적층형 초전도 다심 선재 제조)

  • Yun, K.S.;Ha, H.S.;Oh, S.S.;Moon, S.H.;Kim, C.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.4-7
    • /
    • 2012
  • Coated conductors have been developed to increase piece length and critical current for electric power applications. Otherwise, Many efforts were carried out to reduce AC loss of coated conductor for AC applications. Twisting and cabling processes are effective to reduce AC loss but, these processes can not be applied for tape shaped coated conductor. It is inevitable to have thin rectangular shape because coated conductor is fabricated by thin film deposition process on metal substrate. In this study, round shape superconducting wire was first fabricated using coated conductors. First of all, Ag coated conductor was used. coated conductor was slitted to several wires with narrow width below 1mm. 12ea slitted wires were parallel stacked on top of another until making up the square cross-section. The bundle of coated conductors was heat treated to stick on each other by diffusion bonding and then copper plated to make round shape wire. Critical current of round wire was measured 185A at 77K, self field.

Estimation of the critical current of CORC® conductor using the measured magnetization losses

  • Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Woo-Seok, Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.46-49
    • /
    • 2022
  • Since CORC®(Conductor on Round Core) is made of multiple strands of a superconducting tape to conduct a large current, it is difficult to measure the critical current due to the limitation of a capacity of a power supply. The magnetization loss of a superconductor is dependent on the full penetration field. The full penetration field corresponds to the inflection point of the magnetization loss graph with respect to the external magnetic field. We propose a method to predict the critical current of CORC® indirectly. This method uses the measured magnetization losses of various CORC® samples for the prediction of the critical currents.

Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire (통전 중 산불에 노출된 가공송전선의 온도 및 장력 변화 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.366-371
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperatures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

Application of Nano Coating to ACSR conductor for the Protection of Transmission lines against Solar Storms, Surface Flashovers, Corona and Over voltages

  • Selvaraj, D. Edison;Mohanadasse, K.;Sugumaran, C. Pugazhendhi;Vijayaraj, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2070-2076
    • /
    • 2015
  • Nano composite materials were multi-constituent combinations of nano dimensional phases with distinct differences in structure, chemistry and properties. Nano particles were less likely to create large stress concentrations and thereby can avoid the compromise of the material ductility while improve other mechanical properties. Corona discharge was an electrical discharge. The ionization of a fluid surrounding a conductor was electrically energized. This discharge would occur when the strength of the electric field around the conductor was high enough to form a conductive region, but not high enough to cause electrical breakdown or arcing to nearby objects. This paper shows all the studies done on the preparation of nano fillers. Special attention has given to the ACSR transmission line conductor, TiO2 nano fillers and also to the evaluation of corona resistance on dielectric materials discussed in detail. The measurement of the dielectric properties of the nano fillers and the parameters influencing them were also discussed in the paper. Corona discharge test reveals that in 0%N ACSR sample corona loss was directly proportional to the applied line voltage. No significant change in corona loss between 0%N and 1%N. When TiO2 nano filler concentration was increased up to 10%N fine decrement in corona loss was found when compared to base ACSR conductor, corona loss was decreased by 40.67% in 10%N ACSR sample. It was also found from the surface conditions test that inorganic TiO2 nano filler increases the key parameters like tensile strength and erosion depth.

Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire (산불에 의한 활선선로의 이도변화 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1295_1296
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperaures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

  • PDF