• 제목/요약/키워드: Conductive heat transfer

검색결과 115건 처리시간 0.024초

확장표면을 적용한 액체식 제습기의 열물질 전달 모델링 (Modelling of the Heat and Mass Transfer in a Liquid Desiccant Dehumidifier with Extended Surface)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.303-311
    • /
    • 2011
  • This study presents a new idea of liquid desiccant dehumidifier with extended surface to improve the compactness. Extended surface is inserted between vertical cooling tubes, and the liquid desiccant flows down along the tube walls and the extended surface as well. Though the extended surface contributes to the increase in the mass transfer area, the effect tends to be limited because less conductive non-metallic materials need to be applied due to the high corrosiveness of liquid desiccant. To analyze the effects of the extended surface insertion, mathematical modelling and numerical integration are performed for the heat and mass transfer in the liquid desiccant dehumidifier. The results show that, though the liquid desiccant on the extended surface is heated due to the moisture absorption, the temperature can be maintained by periodic mixing at the contact points between the tube and the extended surface with the liquid desiccant stream from the tube side at a relatively low temperature. This implies the absorption heat from the extended surface side can be removed effectively by mixing, which leads to a substantial improvement of the dehumidification in the liquid desiccant dehumidifier with extended surface. When the interval of the extended surface, $p_e/L$, is less than 0.1, the dehumidification is shown to increase by more than two times compared with that without extended surface.

레토르트 파우치 고추장의 적정 고온 살균조건에 관한 연구 (Studies on the Optimal Sterilization Conditions of Red Pepper Paste Packed in Retort Pouch.)

  • 이신영;최국지;이상규
    • 산업기술연구
    • /
    • 제3권
    • /
    • pp.87-94
    • /
    • 1983
  • Heating characteristics of red pepper paste packed in report pouches of various thicknesses and their storage stability were investigated to determine the adequate processing conditions that good bacteriological safty and minimal quality changes could be obtained, when sterilized by using a steam-air system retort. A heat penetration into pouch-packed red pepper paste was carried out through by a conductive heat transfer, indicating a simple logarithmic heating curve, and the smaller thickness revealed the higher heat penetration rate, suggesting the possibility of high temperature-short time sterilization of red pepper paste. The processing conditions with Fo-value of 4.5 or higher were sufficient for keeping up bacterial safty, but based on C-value, better quality retention was obtained at pouch thickness of 15mm under the processing temperature of $120^{\circ}C$. Subsequent storage study revealed that the red pepper paste packed in 15mm and processed at $120^{\circ}C$ with Fo=4.5 could be held without any spoilage and overall acceptance change, when stored for 6 months at room temperature under the relative humidity of 70%. After 3 months storage in $38^{\circ}C$ under saturation humidity, overall acceptance of red pepper paste were judged not to be maintainable on the acceptable level, but it may be suggested that above the results could be kept up a desirable quality without any remarkable deterioration.

  • PDF

귀 체온계 측온부의 이중 사출 공정 최적화에 관한 연구 (A study on optimization of the double injection process for temperature measuring part of an ear thermometer)

  • 백승익;정욱철;김인관;신광일;김태완
    • Design & Manufacturing
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2022
  • The importance of fast and accurate body temperature measurement with a portable thermometer is increasing. In order to reduce the temperature measurement response time of the infrared ear thermometer, it is very important to develop a structure for a thermometer having an efficient heat transfer path. Most of the existing ear thermometers are single structures that do not consider thermal efficiency, which may delay measurement time and reduce measurement accuracy. Therefore, in this study, the upper part of the thermometer in contact with the ear is made of a thermally conductive material, and the lower part of the thermometer is made of a thermal barrier material so that heat can be concentrated on the infrared sensor of the thermometer by blocking the upper part of the heat. For the efficiency of production, it was intended to be manufactured through the double injection process, and for this purpose, in this paper, the optimal process parameters were derived through the double injection process analysis.

욕조의 보온성능연구 (A Performance Equation of Bath Tubs)

  • 이병호;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

다공성 철 분말을 이용한 열전지용 열원 적합성 연구 (Study on the Suitability of Heat Source for Thermoelectric Cells Using Porous Iron Powder)

  • 김지연;윤현기;임채남;조장현
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.377-385
    • /
    • 2022
  • Thermal batteries are specialized as primary reserve batteries that operate when the internal heat source is ignited and the produced heat (450~550℃) melts the initially insulating salt into highly conductive eutectic electrolyte. The heat source is composed of Fe powder and KClO4 with different mass ratios and is inserted in-between the cells (stacks) to allow homogeneous heat transfer and ensure complete melting of the electrolyte. An ideal heat source has following criteria to satisfy: sufficient mechanical durability for stacking, appropriate heat calories, ease of combustion by an igniter, stable combustion rate, and modest peak temperature. To satisfy the aforementioned requirements, Fe powder must have high surface area and porosity to increase the reaction rate. Herein, the hydrothermal and spray drying synthesis techniques for Fe powder samples are employed to investigate the physicochemical properties of Fe powder samples and their applicability as a heat source constituent. The direct comparison with the state-of-the-art Fe powder is made to confirm the validity of synthesized products. Finally, the actual batteries were made with the synthesized iron powder samples to examine their performances during the battery operation.

수증기-메탄 혼합비에 따른 개질 튜브 내 온도 및 화학반응 특성 (Characteristics of Temperature in Reformer Tube and Chemical Reaction for Steam Methane Ratio)

  • 한준희;김지윤;이성혁
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 연구의 목적은 실제 산업현장에서 사용되는 수소 개질로 내 개질가스의 수증기-메탄 혼합비에 따른 튜브 내 온도 및 화학반응 특성을 수치 해석하는 것이다. 탄화수소의 수증기 개질반응은 800 K - 1000 K 이상의 고온에서 발생하기 때문에 대류, 전도 및 복사 열전달을 고려한 복합 열전달을 고려해야 한다. 수치해석은 상용 전산유체역학(CFD) 코드(ANSYS Fluent V.13.0)를 사용하였다. 본 연구에서 해석을 위해 Reynolds-Averaged Navier-Stokes, 운동량 및 에너지 방정식을 사용하고, 화학반응이 발생하는 튜브 내부는 니크롬 재질의 다공성 영역으로 가정하였다. 개질 튜브 내 온도 및 화학반응 특성을 비교하기 위해 메탄과 수증기의 혼합비를 1-6으로 증가시켜 비교 분석하였다. 수치해석 결과, 메탄에 대한 수증기 비율이 높을수록 튜브 내부의 온도가 증가하고, 메탄의 전화율이 증가한다. 그러나 수소 개질량은 수증기와 메탄의 비율이 5일 때 가장 많은 것을 알 수 있다.

열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 - (Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid)

  • 김태일;김기현
    • 태양에너지
    • /
    • 제12권3호
    • /
    • pp.37-46
    • /
    • 1992
  • 상변화 물질로 Paraffin wax를 사용한 잠열축열 시스템의 축열성능을 실험을 통하여 조사하였다. 가열유체로는 ethylene glycol을 사용하였고 왁스로의 전열을 위해 열싸이폰을 사용하였다. 왁스의 유효열전도율을 높이기 위해 여러장의 구리망을 왁스에 넣었고 실험은 체적비 2%, 3%, 4%에 대해 유량을 변화시키며 수행하였으며 몇가지 주요결과는 다음과 같다. (1) 구리망은 열전도를 촉진시켜 왁스의 온도를 균일화 하는 역할을 한다. (2) 구리망수의 증가는 열전도를 향상시키는 반면 응해된 왁스의 대류작용을 억제한다. (3) 축열시스템에 최적인 구리망의 수가 존재하며 이 연구에서는 체적비로 나타낼 때 $3{\sim}4%$인 것으로 나타났다.

  • PDF

글라스 비즈 - 고무 분말 혼합물의 열전달 특성 연구 (Characterization of Thermal Properties for Glass Beads - Rubber Mixture)

  • 이정훈;윤태섭;매튜 에반스
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.39-45
    • /
    • 2011
  • 본 연구는 글라스 비드와 고무 혼합재의 부피비와 상대적인 크기 비에 따른 열적 거동에 관해 다루고 있다. 혼합 물질의 열전도도를 측정하기 위하여 비정상면열원법이 사용되었다. 개별요소법과 열 네트워크 모델을 결합하여 입상체 모사 시료에서 입자 단위의 열전달 매커니즘을 분석하였다. 실험 및 해석의 결과는 다음과 같다. 유효 열전도도는 고무의 부피비가 증가할수록 감소한다. 두 물질의 상대적인 크기는 열 전파경로의 대부분을 결정하는 입자간 접촉상태의 공간적 구성을 지배한다. 같은 부피비를 갖는 혼합물질 중에서, 열이 잘 흐르지 않는 물질(여기에서는 고무)의 입자 크기가 큰 경우 열전달이 더 원활하게 이루어진다. 이상의 실험결과와 입자 단위의 관찰은 물질의 열적 거동이 부피비 뿐 아니라 구성 성분의 공간적인 구성에도 영향을 받음을 보여준다.

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF

Temperature Uniformity of the Glass Panel Heated in the Infrared Heating Chamber

  • Lee, Kong-Hoon;Kim, Ook-Joong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권10호
    • /
    • pp.1950-1956
    • /
    • 2005
  • An analysis has been carried out to investigate the effect of the reflectivity on the temperature distribution of a glass panel by infrared radiant heating. Halogen lamps are used to heat the panel, located near the top and bottom of the rectangular chamber. The thermal energy is transferred from the lamps to the panel only by radiation and it is considered by using view factor. The conductive transfer is limited inside the panel. The results show that the uniformity of the temperature distribution of the panel is improved and, at the same time, the time for heating increases as the wall reflectivity increases. The temperature difference between the center and the corner reaches a maximum in the early stage of the heating process and then decreases until it reaches a uniform steady-state value.