• 제목/요약/키워드: Conductive Textile

검색결과 88건 처리시간 0.024초

생체 신호 측정을 위한 섬유전극의 형태에 따른 전기적 특성 분석 및 비교 (Analysis and comparison of textile electrode's electrical characteristics in several shapes for biopotential signals)

  • 이영재;이강휘;이정환;강다혜;조하경;조현승;이주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.371-372
    • /
    • 2008
  • Many kinds of electrodes have been developed in various forms and shapes for measurement of bio potential signal. Textile electrode has benefit of collect long tenn data monitoring because of it is non-consciousness, convenient and do not occur skin irritation. However, It is very difficult to acquire available data due to high impedance of electrode and unstable skin-electrode contact which generate motion artifact. Also snap button which usually used as mediator between textile and measurement device cause change of electrical characteristics. In this paper, we inflated textile electrode to stabilize contact and add conductive silver paste between textile and snap button to improve conductance. To compare the performance of two methods, flat or inflated and add conductive paste or not, four types of electrodes are tested on each impedance and SNR by ECG measurement. In result, the first type electrode which flat and non-conductive paste showed the worst performance and the last type electrode which is inflated shape and contain conductive paste show the best performance.

  • PDF

Development of Textile Proximity Sensor for Medication Adherence Management System

  • Ho, Jong Gab;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권2호
    • /
    • pp.919-931
    • /
    • 2018
  • In this study, we developed textile proximity sensor using conductive textile to develop a Medication adherence management system. The textile proximity sensor utilizes the principle of the capacitor, and the ring type sensor used to reduce the fringe-effect. When take medicines, we made a custom PCB that converts the change of the data measured by the sensor into a digital value so that transmitted the PC. In order to compare the performance of the system, we evaluated the correlation between the data variation according to the quantity of pills in the electronic compact scale and the data in this system. As a result, Pearson's correlation coefficient was 0.956(p<0.01), confirmed a good correlation between the scale and our system. Therefore, we concluded that our system evaluated able to whether or not to take medication.

A Study on the E-textiles Dip-Coated with Electrically Conductive Hybrid Nano-Structures

  • Lee, Euna;Kim, Jongjun
    • 패션비즈니스
    • /
    • 제21권6호
    • /
    • pp.16-30
    • /
    • 2017
  • Currently, e-textile market is rapidly expanding and the emerging area of e-textiles requires electrically conductive threads for diverse applications, including wearable innovative e-textiles that can transmit/receive and display data with a variety of functions. This study introduces hybrid nano-structures which may help increase the conductivity of the textile threads for use in wearable and flexible smart apparels. For this aim, Ag was selected as a conductive material, and yarn treatment was implemented where silver nanowire (AgNW) and graphene flake (GF) hybrid structures overcome the limitations of the AgNW alone. The yarn treatment includes several treatment conditions, e.g., annealing temperature, annealing time, binder material such as polyurethane (PU), coating time, in order to search for the optimum method to form stable conductive nano-scale composite materials as thin film on the surface of textile yarns. Treatedyarns showed improved electrical resistance readings. The functionality of the spandex yarn as a stretchable conductive thread was also demonstrated. When the yarn specimens were treated with colloid of AgNW/GF, relatively good electrical conductivity value was obtained. During the extension and recovery cycles of the treated yarns, the initial resistance values did not deteriorate significantly, since the network of nanowire structure with the support of GF and polyurethane stayed flexible and stable. Through this research, it was found that when one-dimensional structure of AgNW and two-dimensional structure of GF were mixed as colloids and treated on the surface of textile yarns, flexible and stretchable electrical conductor could be formed.

침대 형태에서 기능성 직물 전도성 전극 위치에 대한 심전도 측정 방법의 Pilot Test (Pilot Test of Electrocardiogram Measurement Method for Conductive Textiles Electrode Position in Bed Condition)

  • 최준원;;송창현;정하림;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권1호
    • /
    • pp.80-84
    • /
    • 2023
  • Electrodes are one of the types of biosensors capable of measuring bio signals, such as electrocardiogram (ECG) and electromyogram (EMG) signals. These electrodes are used in various fields and offer the advantage of being able to measure ECG signals without the need for skin attachment, compared to Ag/AgCl electrodes. The purpose of this study was to evaluate the efficacy of conductive textile electrodes in collecting ECG signals in a bed-like environment. Three adult participants were involved, and a total of 30 minutes of ECG signals were collected for each participant. The collected ECG signals were analyzed to determine the heart rate, normLF and a comparison was made between the conductive textile electrodes and Ag/AgCl electrodes. As a result, the change in heart rate and normLF could be observed, and in particular, the difference between the two electrodes decreased. This study confirmed that conductive textile electrodes can effectively collect ECG signals in a bed-like environment. It is hoped that this research will lead to the development of a system that can detect various sleep-related diseases through the use of these electrodes.

The Synthesis of Copper Nanowire with high aspect ratio by capping agent for textile electronics

  • Byun, Woonghee;Kim, Minho;Kim, Yong-Hoon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.379.1-379.1
    • /
    • 2016
  • Recently, new types of wearable devices such as textile electronics are considered as the next generation wearable electronics. To realize the textile electronics, conductive fibers are required to supply the power and for signal processing. Conventionally, silver nanowires (Ag NWs) have been attracted as one of the conductive additives in the fibers, however, using the Ag NWs may lead to high production cost since it is a noble metal. Many researches have been done to replace the Ag NWs into a cheaper materials such as copper nanowires (Cu NWs). Here, we synthesized ultra-long Cu NWs for a conductive filler material in conductive fibers, taking advantages of their structural features. To investigate the effect of capping agents on the aspect ratio of the synthesized Cu NWs, we used various capping agents such as hexadecylamine, butylamine, ethylenedilamine and oleylamine in the Cu NW synthesis. In this research, the effects of capping agents on the structure and the synthesis of Cu NWs are presented.

  • PDF

Wearable Personal Network Based on Fabric Serial Bus Using Electrically Conductive Yarn

  • Lee, Hyung-Sun;Park, Choong-Bum;Noh, Kyoung-Ju;SunWoo, John;Choi, Hoon;Cho, Il-Yeon
    • ETRI Journal
    • /
    • 제32권5호
    • /
    • pp.713-721
    • /
    • 2010
  • E-textile technology has earned a great deal of interest in many fields; however, existing wearable network protocols are not optimized for use with conductive yarn. In this paper, some of the basic properties of conductive textiles and requirements on wearable personal area networks (PANs) are reviewed. Then, we present a wearable personal network (WPN), which is a four-layered wearable PAN using bus topology. We have designed the WPN to be a lightweight protocol to work with a variety of microcontrollers. The profile layer is provided to make the application development process easy. The data link layer exchanges frames in a master-slave manner in either the reliable or best-effort mode. The lower part of the data link layer and the physical layer of WPN are made of a fabric serial-bus interface which is capable of measuring bus signal properties and adapting to medium variation. After a formal verification of operation and performances of WPN, we implemented WPN communication modules (WCMs) on small flexible printed circuit boards. In order to demonstrate the behavior of our WPN on a textile, we designed a WPN tutorial shirt prototype using implemented WCMs and conductive yarn.

심장 전기활동 계측을 위한 소형 섬유전극 개발 및 특성 고찰 (Development of Miniaturized Textile Electrode for Measuring Heart Electric Activity)

  • 이영재;이정환;양희경;이주현;강다혜;조현승;안인석
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1186-1193
    • /
    • 2009
  • Wearable ECG monitoring is regarded as one of the most essential part in the ubiquitous healthcare environment and subsequently day-life monitoring of a heart condition has been pursued especially for the elder people. However, there are many problems to accomplish this task such as; i) implementation of long-term monitoring device, ii) development of non-irritating electrode on skin and iii) stable signal acquisition. With these aims, we have focused on implementing a non-irritating electrode with an endurable monitoring device for day-life. To accomplish our tasks, we basically developed four different types of textile electrodes that are adapted by both shape and the composed material; flat or convex shape and Ag-conductive paste material or not. It turns out to be that a convex shape and Ag-paste textile electrode has the best performance in terms of both signal-to-noise ratio (SNR) and Impedance/Phase characteristics. Furthermore, ECG amplifier (35 ${\times}$ 35 mm) has developed to resolve the ECG signal and transfer the signal to desktop computing device or portable one by RF serial communication.

전도성 에폭시를 이용한 직물 위에 구현된 건식 생체전위 전극의 연구 (Study on Micro Dried Bio-potential Electrodes Using Conductive Epoxy on Textile Fabrics)

  • 차두열;정정모;김덕수;양희준;최교상;최종명;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제26권5호
    • /
    • pp.367-372
    • /
    • 2013
  • In this paper, micro dried bio-potential electrodes are demonstrated for sEMG (surface ElectroMyoGraphic) signal measurement using conductive epoxy on the textile fabric. Micro dried bio-potential electrodes on the textile fabric substrate have several advantages over the conventional wet/dry electrodes such as good feeling of wearing, possibility of extended-wearing due to the good ventilation. Also these electrodes on the textile fabric can easily apply to the curved skin surface. These electrodes are fabricated by the screen-printing process with the size of $1mm{\times}10mm$ and the resultant resistance of these electrodes have the average value of $0.4{\Omega}$. The conventional silver chloride electrode shows the average value of $0.3{\Omega}$. However, the electrode on the textile fabric are able to measure the sEMG signal without feeling of difference and this electrode shows the lower resistance of $1.03{\Omega}$ than conventional silver chloride electrode with $2.8{\Omega}$ in the condition of the very sharp curve surface (the radius of curvature is 40 mm).

전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구 (Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode)

  • 이계형;박성빈;윤형로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권7호
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

Development and Usability Test of Baby Vest Prototypes with a Body Temperature Sensing Function

  • Yi, Kyong-Hwa;Song, Hayoung
    • 한국의류학회지
    • /
    • 제44권3호
    • /
    • pp.427-440
    • /
    • 2020
  • This study developed a vest prototype capable of monitoring body temperature using textile electrodes to prevent the sudden death of babies as well as to determine the quality of developed products by evaluating usability with commercial products. Based on the results of the 7th Size Korea Project, a basic pattern for a vest prototype was drafted by applying the average size of two-year-old Korean babies. Two prototypes were the detachable (VEST I) and integrated textile electrodes vest type (VEST II), which followed the same design. The materials were 100% cotton single jersey (SJ) and double jersey (DJ). Six experts evaluated the usability of the developed vests (VEST I & VEST II) and commercial product (VEST M). The single-layer woven textile electrode appeared to have a slightly higher conductivity than the double-layer one. There was no statistical difference in the body temperature sensing function between VEST I and VEST II. Finally, the superiority of the VEST I was verified through a comparison with commercial products (VEST M). The usability test suggested that a wearable smart clothing system of the integrated conductive textile could be further commercialized for bio-monitor applications in Ubiquitous-health care.