• Title/Summary/Keyword: Conduction system

Search Result 724, Processing Time 0.03 seconds

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

The electrical conduction characteristics of polymide thin films fabricated by vapor deposition polymerization(VDP) method based on PMDA and 4,4'-DDE monomer (진공증착중합법을 이용하여 PMDA와 4,4'-DDE 단량체로 제조한 polyimide박막의 전기전도 특성)

  • 김형권;이덕출
    • Electrical & Electronic Materials
    • /
    • v.9 no.8
    • /
    • pp.776-782
    • /
    • 1996
  • The electrical properties of vapor deposition polymerized polymide thin films for getting an in-line system with manufacturing process of semiconductor device, have been studied. Polyimide thin films fabricated by vapor deposition polymerization(VDP) method based on PMDA and 4,4'-DDE monomer were confirmed by FT-IR spectra. It is found that the major conduction carriers of thin films are ions, and the hopping length of ions is almost same with monomer length at the temperature over 120.deg. C through the analysis of electrical conduction mechanism. Also, The activation energy is about 0.69 eV at the temperature of >$30^{\circ}C$ - >$150^{\circ}C$ and it is shown that the resistivity at which thin films can be used as an insulating film between layers of semiconductor device, is 3.2*10$^{15}$ .ohm.cm.

  • PDF

A boundary element method based on time-stepping approximation for transient heat conduction in anisotropic solids

  • Tanaka, Masa;Matsumoto, T.;Yang, Q.F.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.1
    • /
    • pp.61-72
    • /
    • 1996
  • The time-stepping boundary element method has been so far applied by the authors to transient heat conduction in isotropic solids as well as in orthotropic solids. In this paper, attempt is made to extend the method to 2-D transient heat conduction in arbitrarily anisotropic solids. The resulting boundary integral equation is discretized by means of the boundary element with quadratic interpolation. The final system of equations thus obtained is solved by advancing the time step from the given initial state to the final state. Through numerical compuation of a few examples the potential usefulness of the proposed method is demonstrated.

The Analysis of Conduction and Switching Losses in Multi-Level Inverter System (멀티레벨 인버터 시스템의 전도손실과 스위칭손실 해석)

  • 金 兌 珍;姜 岱 旭;;玄 東 石
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.111-120
    • /
    • 2002
  • The multi-level inverter system is very promising in ac drives, when both reduced harmonic contents and high power are required. In case of multi-level inverter system, the loss of switch devices cannot be analyzed by conventional methods. The reason is that the loss of each the switch device is different from one another unlike 2-level. In this paper, a simple and accurate method of computing conduction and switching loss is proposed for multi-level inverter system. The validity of the proposed method is proven for 3-level and 4-revel diode clamped inverter system.

A review on the effect of a floor heating system on the human body (기존문헌조사에 의한 바닥난방의 인체영향에 관한 연구)

  • 최영식
    • Journal of the Korean housing association
    • /
    • v.3 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A floor system have played a major part in the living in Korean house. It is an essential element in the residential houses. Uufortunately, a design method of the floor heating system for the human thereat comfort has not established in Korea system. This paper aims to review the previous researches to find the issue for the futher study of comfort floor heating design. The following results were obtained: 1) Nevins et at conducted experiments on the effect of the comfortable of floor and air temperatures on the psychological responses by a large number of subjects. Its objective was to find the combined condition to obtain thermal comfort for sedentary posture.7here has never been researches regarding a sitting Person on the heated floor. 2) Some investigation in Japan on the effect of floor heating system on a sitting person on the floor have been conducted for these years, but they are net based on the human heat balance but on only psychological responses. 3) Hirayama et al developed an indication method of the effect of heat conduction on the sedentary person.4) There are few researches on the human thermal comfort compared whth indoor environmental researches on mechanical controls in Korea. Thus, the further study on the followings in needed the estimaiing of heat conduction between tile hunman body and a floor, developing an index expressed the combined effect of convection, radiation and conduction and its associated experiments.

  • PDF

Analysis of Inverse Heat Conduction Problem Using OpenFOAM and VisualDoc (OpenFOAM 과 VisualDoc 을 이용한 역열전도 문제의 해석)

  • Kim, Sung-Won;Kim, Sun Kyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.539-544
    • /
    • 2013
  • This study provides a solution method for the inverse heat conduction problem based on a combination of a public domain CAE (computer aided engineering) software and a commercial CAO (computer aided optimization) software. The solver system has been implemented without any in-house coding. The proposed method is simple to implement. Moreover, it can be easily reproduced.

A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor (바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

Study on the Electrical Insulation of Current Lead in the conduction-cooled 1-2kV Class High-Tc Superconducting DC Reactor (전도냉각되는 1-2kV급 고온초전도 직류리액터 전류도입부의 전기적 절연에 대한 연구)

  • 배덕권;안민철;이찬주;정종만;고태국;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.30-34
    • /
    • 2002
  • In this Paper, Insulation of current lead in the conduction-cooled DC reactor for the 1.2kV class 3 high-Tc superconducting fault current limiter(SFCL) is studied. Thermal link which conducts heat energy but insulates electrical energy is selected as a insulating device for the current lead in the conduction-cooled Superconducting DC reactor. It consists of oxide free copper(OFC) sheets, Polyimide films, glass fiberglass reinforced Plastics (GFRP) plates and interfacing material such an indium or thermal compound. Through the test of dielectric strength in L$N_2$, polyimide film thickness of 125 ${\mu}{\textrm}{m}$ is selected as a insulating material. Electrical insulation and heat conduction are contrary to each other. Because of low heat conductivity of insulator and contact area between electrical insulator and heat conductor, thermal resistance of conduction-cooled system is increased. For the reducing of thermal resistance and the reliable contact between Polyimide and OFC, thermal compound or indium can be used As thermal compound layer is weak layer in electrical field, indium is finally selected for the reducing of thermal resistance. Thermal link is successfully passed the test. The testing voltage was AC 2.5kVrms and the testing time was 1 hour.

A Study of the Peripheral Neuropathy among the Workers Exposed to Carbon Disulfide (이황화탄소에 폭로된 근로자들의 말초신경병증에 관한 연구)

  • Kim, Dae-Seong;Kim, Soon-Duck;Cha, Chul-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.282-292
    • /
    • 1993
  • Neurotoxicity in the workplace may occur with exposure to scores of chemicals. Although large acute outbreaks of the occupational neurological disease are rare, the incidence of occupational neurotoxicity in its subtler aspects is unknown. A working knowledge of both the major occupational neurotoxic solvents and the tools used by cliniical neurologists and neurotoxicologists to evaluate neurotoxicity in working populations is a necessity fur the occupational physician. To investigate the effects of carbon disulfide($CS_2$) on the peripheral nerve system using the nervous conduction study, 105 male workers working in the spinning room of a viscose rayon factory were examined and compared with a sex and age matched, unexposed 105 male controls using t-test analysis. 72.4% of $CS_2$-exposed workers complained of neurological symptoms, and the abnormal cases in nerve conduction study were 48.6%. The abnormal cases of nerve conduction study increased in number according as the age and duration of exposure increased. In this study, asymptomatic workers were confirmed to have subclinical neuropathy by nerve conduction study. Also as there were abnormal cases even in its duration of exposure below 4 years, nerve conduction study turned out to be ways of discovering of early peripheral neuropathy. In nerve conduction study, the amplitude, velocity, F-wave latency and H-reflex of the motor and sensory nerves in both upper and lower extremities were significant different between $CS_2$-exposed workers and the controls. From the pathological viewpoint, both segmental and axonal degenerations were assumed in this study.

  • PDF