• 제목/요약/키워드: Conduction system

검색결과 726건 처리시간 0.023초

이황화탄소에 폭로된 근로자들의 말초신경병증에 관한 연구 (A Study of the Peripheral Neuropathy among the Workers Exposed to Carbon Disulfide)

  • 김대성;김순덕;차철환
    • Journal of Preventive Medicine and Public Health
    • /
    • 제26권2호
    • /
    • pp.282-292
    • /
    • 1993
  • Neurotoxicity in the workplace may occur with exposure to scores of chemicals. Although large acute outbreaks of the occupational neurological disease are rare, the incidence of occupational neurotoxicity in its subtler aspects is unknown. A working knowledge of both the major occupational neurotoxic solvents and the tools used by cliniical neurologists and neurotoxicologists to evaluate neurotoxicity in working populations is a necessity fur the occupational physician. To investigate the effects of carbon disulfide($CS_2$) on the peripheral nerve system using the nervous conduction study, 105 male workers working in the spinning room of a viscose rayon factory were examined and compared with a sex and age matched, unexposed 105 male controls using t-test analysis. 72.4% of $CS_2$-exposed workers complained of neurological symptoms, and the abnormal cases in nerve conduction study were 48.6%. The abnormal cases of nerve conduction study increased in number according as the age and duration of exposure increased. In this study, asymptomatic workers were confirmed to have subclinical neuropathy by nerve conduction study. Also as there were abnormal cases even in its duration of exposure below 4 years, nerve conduction study turned out to be ways of discovering of early peripheral neuropathy. In nerve conduction study, the amplitude, velocity, F-wave latency and H-reflex of the motor and sensory nerves in both upper and lower extremities were significant different between $CS_2$-exposed workers and the controls. From the pathological viewpoint, both segmental and axonal degenerations were assumed in this study.

  • PDF

1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석 (Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor)

  • 권다어반;레덧탕;성해진;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제23권1호
    • /
    • pp.31-41
    • /
    • 2018
  • 이 논문에서는 대 전류, 고온 초전도 직류 리액터를 위한 전도 냉각 시스템의 구조 설계에 대해 논의하고자 한다. 초전도 자석, 보 빈, 전류 리드, 고정용 구조물 그리고 열 교환기가 포함된 전도 냉각 시스템 부품의 크기를 3D CAD 프로그램을 사용하여 계산하였다. 또한, 최적의 설계 변수를 결정하고 열적-기계적 특성을 분석하기 위해서 유한 요소법 모델을 제작하였다. 리액터 자석의 운전 전류와 인덕턴스는 각각 1,500 A 400 mH이며, 이에 따른 극저온 냉동기의 냉각 용량을 결정하기 위해 초전도 직류 리액터에서 발생하는 열 부하를 계산하였다. 또한, 대 전류가 흐르는 1 단부전도 냉각 시스템의 작동 테스트를 수행하였다. 구리 바는 40 K까지 냉각되었고 초전도 리드는 안정적으로 작동했다. 실험 결과로써, 1 단부 영역의 총 열 부하는 190 W였다. 본 연구 결과는 상용 초전도 직류 리액터의 설계 및 제조에 있어 효과적으로 활용 될 것이다.

유한체적 복사전달해석법을 이용한 주유동중에 놓인 원형실린더 주위에서의 복사-대류 열전달해석 (Analysis of Radiative-Convective Heat Transfer about a Circular Cylinder in Crossflow Using Finite Volume Radiation Solution Method)

  • 이공훈;이준식
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.346-358
    • /
    • 1996
  • A finite volume radiation solution method was applied to a non- orthogonal coordinate system for the analysis of radiative-convective heat transfer about a circular cylinder in crossflow. The crossflow Reynolds number based on the cylinder radius was 20, and the fluid Prandtl number was 0.7. The radiative heat transfer coupled with convection was reasonably predicted by the finite volume radiation solution method. The investigation includes the effects of conduction- to-radiation parameter, optical thickness, scattering albedo and cylinder wall-emissivity on heat transfer about the cylinder. As the conduction- to-radiation parameter decreases, the radiative heat transfer rate increases and conduction rate as well due to the increase in temperature gradient on the cylinder wall which is caused by radiation enhancement. With an increase in the optical thickness, the Nusselt number increases significantly and the temperature gradient shows similar behavior. Though the radiative heat transfer increases with the scattering albedo, the total heat transfer decreases. This is because the decrease in the conduction heat transfer exceeds the increase in the radiation heat transfer. As the wall- emissivity increases, the radiation absorbed in the vicinity of the cylinder wall increases and thereby the total heat transfer increases, even though the conduction heat transfer decreases.

Y2O3가 도핑된 SrZrO3-금속전극계의 전기전도 특성 (Electrical Conduction in Y2O3-doped SrZrO3-metal Electrode System)

  • 백현덕;이풍헌
    • 한국세라믹학회지
    • /
    • 제39권4호
    • /
    • pp.367-376
    • /
    • 2002
  • $SrZr_{1-x}Y_xO_{3-\delta}$(x=0.05, 0.10)-금속전극 계에서 임피던스법과 d.c.법으로 전기전도도를 측정함으로써 고체전해질 및 전극전도도를 고찰하였다. 고체전해질과 anode를 통한 전기전도도는 $P_W^{1/2}$(PW는 수증기분압)에 의존하여 증가함을 보였다. Cathode 전도도는 $P_{O2}^{1/4}$에 비례함을 보였으며, 수증기분압 증가와 함께 감소하여 고체전해질내의 전자 결함의 농도와 함께 증가하는 것을 알 수 있었다. 수소분위기에서는 수증기의 첨가가 anode와 cathode 두 방향의 전극반응 속도 모두를 촉진하였다. 도펀트 첨가량이 5%에서 10%로 증가될 때 anode와 고체전해질의 전기전도도가 3배 이상 크게 증가하여 유효 산소이온공공의 농도가 급격히 증가함을 알 수 있었다. Pt와 Ag전극을 통한 cathode 전도도의 활성화에너지가 거의 같은 값을 나타냈으며 이는 cathode반응의 속도가 금속전극이 아니라 고체전해질표면에서 일어나는 반응에 의하여 결정되는 것으로 해석되었다.

HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구 (Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling)

  • 박재홍;권용하;김영수;박성출
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental of the Rotaing Cryogenic System)

  • 이창규;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

Electric Therapy System Based on Discontinuous Conduction Mode Boost Circuit

  • Chen, Wenhui;Lee, Hyesoo;Jung, Heokyung
    • Journal of information and communication convergence engineering
    • /
    • 제18권4호
    • /
    • pp.245-253
    • /
    • 2020
  • The human body and nervous system transmit information through electric charges. After the electric charge transmits information to the brain, we can feel pain, numbness, comfort, and other feelings. Electric therapy is currently used widely in clinical practice because the field of examination is more representative of electrocardiogram, and in the field of treatment is more representative of electrotherapy. In this study, we design a system for neurophysiological therapy and conduct parameter calculation and model selection for the components of the system. The system is based on a discontinuous conduction mode (DCM) boost circuit, and controlled and regulated by a single-chip microcomputer. The system does not only have a low cost but also fully considers the safety of use, convenience of the human-computer interface, adjustment sensitivity, and waveform diversity in the design. In future, it will have strong implications in the field of electrotherapy.

A Sensorless Switched Reluctance Drive System Based on the Improved Simplified Flux Method

  • Li, Zhenguo;Song, Andong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.477-482
    • /
    • 2012
  • This paper describes a new rotor position sensorless control method for SRM drives based on an improved simplified flux linkage method. In the traditional simplified flux linkage method, every phases take turns conduction and current chopping control method is used. Every phases take turns conduction means turning on the incoming working phase while turning off the working phase. This conduction mode causes coupling between turn-on and turn-off angles, which goes against optimal efficiency or torque ripple minimization with sensorless speed control. In the improved simplified flux linkage method, turn-off angle is calculated by flux loop, the turn-on angle can be given arbitrarily and has no relations with the turn-off angle, and the current chopping control method is used. The speed and rotor position can be estimated then. Finally, a sensorless SRM speed control system and an experiment platform with DSP are built and validity of this method is confirmed.

유도 가열 시스템에서 SiC MOSFET과 GaN Transistor의 성능 비교를 통한 소자 적합성 분석 (Device Suitability Analysis by Comparing Performance of SiC MOSFET and GaN Transistor in Induction Heating System)

  • 차광형;주창태;민성수;김래영
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.204-212
    • /
    • 2020
  • In this study, device suitability analysis is performed by comparing the performance of SiC MOSFET and GaN Transistor, which are WBG power semiconductor devices in the induction heating (IH) system. WBG devices have the advantages of low conduction resistance, switching losses, and fast switching due to their excellent physical properties, which can achieve high output power and efficiency in IH systems. In this study, SiC and GaN are applied to a general half-bridge series resonant converter topology to compare the conduction loss, switching loss, reverse conduction loss, and thermal performance of the device in consideration of device characteristics and circuit conditions. On this basis, device suitability in the IH system is analyzed. A half-bridge series resonant converter prototype using the SiC and GaN of a 650-V rating is constructed to verify device suitability through performance comparison and verified through an experimental comparison of power loss and thermal performance.

22.9kV/630A 저항형 초전도 한류기용 전도-냉각 황동 전류인입선 제작 및 특성 실험 (Fabrication and Characteristic Test of Conduction-Cooled Brass Current Leads for a 22.9kV/630A Resistive Superconducting Fault Current Limiter System)

  • 송정빈;김주형;권나영;김용우;김호민;심정욱;이방욱;김혜림;현옥배;이해근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.46-51
    • /
    • 2007
  • The 22.9kV/630A superconducting fault current limiter (SFCL) is developed by the KEPRI-LSIS collaboration group. This resistive SFCL uses three pairs of conduction-cooled current leads. When the SFCL system is in the fault mode. the current flows 20 times more than the steady state. Therefore. it is important that the current lead is designed to have the thermal stability in order to minimize the heat input of the cold-end. This paper presents the design and performance results of a pair of conduction-cooled brass current leads considering both cases that the SFCL system operates at the steady state and the fault current.