• 제목/요약/키워드: Conducting Filament

검색결과 13건 처리시간 0.017초

The Effects of Mn-doping and Electrode Material on the Resistive Switching Characteristics of ZnOxS1-x Thin Films on Plastic

  • Han, Yong;Cho, Kyoungah;Park, Sukhyung;Kim, Sangsig
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.24-27
    • /
    • 2014
  • In this study, the effects of Mn-doping and the electrode materials on the memory characteristics of $ZnO_xS_{1-x}$ resistive random access memory (ReRAM) devices on plastic are investigated. Compared with the undoped Al/$ZnO_xS_{1-x}$/Au and Al/$ZnO_xS_{1-x}$/Cu devices, the Mn-doped ones show a relatively higher ratio of the high resistance state (HRS) to low resistance state (LRS), and narrower resistance distributions in both states. For the $ZnO_xS_{1-x}$ devices with bottom electrodes of Cu, more stable conducting filament paths are formed near these electrodes, due to the relatively higher affinity of copper to sulfur, compared with the devices with bottom electrodes of Au, so that the distributions of the set and reset voltages get narrower. For the Al/$ZnO_xS_{1-x}$/Cu device, the ratio of the HRS to LRS is above $10^6$, and the memory characteristics are maintained for $10^4$ sec, which values are comparable to those of ReRAM devices on Si or glass substrates.

PCB에서의 ECM 특성에 미치는 SnPb 솔더 합금의 분극거동의 영향 (Influence of Polarization Behaviors on the ECM Characteristics of SnPb Solder Alloys in PCB)

  • 이신복;유영란;정자영;박영배;김영식;주영창
    • 마이크로전자및패키징학회지
    • /
    • 제12권2호
    • /
    • pp.167-174
    • /
    • 2005
  • 전자 부품의 크기가 점점 줄어들고 고집적화됨에 따라 전자 패키지 내부에 사용되는 금속간 간격이 줄어들고 있다. 이에 더하여 고온 고습한 환경에서 금속간에 전압이 인가되면 금속의 이온화가 촉진, 금속으로 이루어진 필라멘트가 형성되어 결국 절연파괴에 이르게 된다. 이러한 현상이 electrochemical migration(ECM)이다. 이에 인쇄회로기판을 사용하여 ECM 특성 평가를 수행하였다. 항온/항습조건($85^{\circ}C,\;85{\%}RH$)에서 PCB의 $300 {\mu}m$의 단자간격을 가진 through-hole via 표면에서 발생하는 ECM 현상은 CAF가 절연파괴의 주된 메커니즘이었다. solder를 구성하는 Sn과 Pb 조성 분석을 통해 Pb 의 이온 이동도가 Sn의 이온 이동도보다 큰 것을 알 수 있었으며 이는 급격한 양극용해 거동을 보이는 pure Pb의 분극거동과 상관관계가 있는 것으로 사료된다. 또한 시간에 따른 절연파괴시간 시험을 통하여 ECM에 의한 절연파괴시간이 인가전압에 의존하며 인가전압 의존성 지수값(n)은 2로 나타났다.

  • PDF

3D 프린팅기술을 이용한 골밀도 정도관리 대퇴골 팬텀 제작 및 유용성 평가 (Evaluation of Usefulness and Fabrication of Femur Phantom on Quality Control of Bone Mineral Density Using 3D Printing Technology)

  • 홍다영;이정;이준호;문재원;오한샘;정유원;진성현;홍종민;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.1-8
    • /
    • 2023
  • As the demand for bone mineral density testing increases in Korea, which is close to an aging society, it is necessary to evaluate the repeatability of equipment such as femur phantom other than l-spine for more accurate diagnosis. However, in clinical practice, it is often not possible to proceed such evaluation due to insufficient quality control conditions. Therefore, this study is to evaluate the usefulness of the femur phantom after fabricating the same using 3D printing technology. The femur phantom was output using GlowFill filament and FDM 3D printing type. Each phantom was repeatedly scaned 20 times to compare whether the existing l-spine phantom and the fabricated femur phantom were suitable as a phantom for quality control. Each time the seven researchers took three times, the location of the femur phantom was readjusted, and then scanned to confirm the error between the researchers. As a result of conducting repeatability evaluation using femur phantom, the coefficient of variation rate was 2%, which was within the minimum precision tolerance of 2.5%. The reproducibility between the researcher was also found to be suitable as the average coefficient of variation was 0.031 and the coefficient of variation rate was 3.1%, which was within the minimum precision error range of 5%. In conclusion, it is considered that the prospective attitude and usefulness of the femur phantom fabricated by 3D printing in clinical practice will be sufficient.