• 제목/요약/키워드: Conditioning effects

검색결과 783건 처리시간 0.025초

협착이 발생된 분기관내 비뉴턴유체의 유동특성 연구 (Flow Characteristics of Non-Newtonian Fluids in the Stenosed Branch Tubes)

  • 서상호;유상신;노형운
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.307-316
    • /
    • 1996
  • The objective of present study is to obtain information on the stenosis effects in the branch tubes for industrial piping system and atherogenesis processing in human arteries. Numerical solutions for flows of Newtonian and non-Newtonian fluids in the branch tubes are obtained by the finite volume method. Centerline velocity and pressure along the bifurcated tubes for water, blood and aqueous Separan AP-273 solution are computed and the numerical results of blood and the Separan solution are compared with those of water. Flow phenomena in the stenosed branch tubes are discussed extensively and predicted effectively. The effects of stenosis on the pressure loss coefficients are determined.

  • PDF

축류형 팬의 저소음화에 관한 연구 (A Study on the Noise Reduction of Axial Flow Fan)

  • 오재응;이승종;이상환;이동익;김철환
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.142-149
    • /
    • 1995
  • Axial fans are very useful cooling devices being widely used in many electric and industrial machinery. However those are often accompanying annoying noise. Many efforts have been devoted in order to reduce the fan noise. In this study, the procedure was devided into two major parts in considering effects of design parameters of axial fan concerned with noise ; the fan theory and the Fukano's fan noise study. By using the fan theory we defined stagger angle, camber angle, blade inlet and outlet angle for studying low noise fan. Then the effects of such angles on the flow rate and static pressure were investigated. By using the Fukano's fan noise theory, the relations of the chord length, the rotational speed and the number of blades vs. fan noise are investigated.

  • PDF

네트워크형 지하도로 입체교차로 내의 교통환기력에 의한 환기 특성 (Ventilation Characteristics by Traffic Piston Effect in Underground Network-type Road Junction)

  • 김남영;조종복;한화택
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.337-343
    • /
    • 2015
  • This paper investigates the ventilation characteristics in a two-dimensional underground network junction composed of four main lines interconnected by eight ramps. Simple one-dimensional models cannot be applied to network junctions since there are interferences of traffic piston effects in the main lines and at the ramps. A numerical algorithm was developed to analyze the pressure and airflow distributions iteratively. The Darcy-Weisbach equation was used to calculate the piston effects by traffic flows, and a Hardy Cross iteration was conducted for network analysis at the interconnected junction. The results show interesting ventilation characteristics and CO concentration distributions depending on system parameters such as vehicle speed, tunnel diameter, and other junction configurations.

밀집형 자연냉매 증발기의 열성능에 미치는 불균일 공기유동분포의 영향 (Effects of Air Flow Nonuniformity on the Thermal Performance of a Compact Evaporator for Natural Working Fluids)

  • 박병규;김근오;김무근
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1114-1124
    • /
    • 2001
  • The application of carbon dioxide as an attractive natural working fluid in air cooling and heating system is increasingly important in view of the CFC substitution problem. The thermal performance of compact evaporator was analyzed using section-by-section method. The effects of the two-dimensional nonuniformity of air flow through the evaporator is presented. The detrimental effect of the aid flaw nonuniformity on the thermal performance of the evaporator is found to be significant for many typical applications. It is shown that total heat transfer rate of evaporator using $CO_2$ is higher than that using R134a at the simulation conditions.

  • PDF

Effects of Turbine Inlet Temperature on Performance of Regenerative Gas Turbine System with Afterfogging

  • Kim, Kyoung-Hoon;Kim, Se-Woong;Ko, Hyung-Jong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권4호
    • /
    • pp.141-148
    • /
    • 2009
  • Afterfogging of the regenerative gas turbine system has an advantage over inlet fogging in that the high outlet temperature of air compressor makes the injection of more water and the recuperation of more exhaust heat possible. This study investigates the effects of turbine inlet temperature (TIT) on the performance of regenerative gas turbine system with afterfogging through a thermodynamic analysis model. For the standard ambient conditions and the water injection ratios up to 5%, the variation of system performance including the thermal efficiency is numerically analyzed with respect to the variations of TIT and pressure ratio. It is also analyzed how the maximum thermal efficiency, net specific work, and pressure ratio itself change with TIT at the peak points of thermal efficiency curve. All of these are found to increase almost linearly with the increases of both TIT and water injection ratio.

인체의 온열환경 적응을 고려한 여름철의 실온 쾌적변동 제어에 관한 연구 (A Study on the Room Temperature Control Methods Considering Human Thermal Comfort Under Hot and Humid Condition)

  • 이주연
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.334-341
    • /
    • 2008
  • The purpose of this study is to investigate the effects of changing air temperature and the changing on/off periods of the air-conditioner system. Adding to that, this paper discuss is to consider the effects of air temperature with the air-conditioner system upon the human thermal comfort. The experiment is conducted during the summer. The subjects(6 young females) are exposed to the following conditions: combinations of 2 Swing and 2 Linear air control Conditions. (2 Swing during 40 min, 4 Swing during 40 min, Linear 40 min, Linear 60 min in still air and RH 50%). From the experiment, the following results are obtained; the thermal sensation vote is neutral after 90 minute. The mean skin temperature ranged about $34^{\circ}C$ at all conditions. The skin temperature was greatly affected by 2 Swing big amplitude condition.

야간 하늘에 노출된 평판의 복사냉각 실험 (Nocturnal Radiant Cooling Experiment by a Plate Viewing the Sky)

  • 변기홍
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.605-610
    • /
    • 2005
  • The purpose of this experiment is to study the radiant cooling effects by a plate directly viewing the nighttime sky. The measurements are performed on a rooftop of the Engineering building at the Dongguk University in Seoul during the month of August in 2004. The radiant cooling effects are compared using three different types of plate sufaces, namely, galvanized iron, black painted, and aluminum film coated galvanized iron plate. Among these plates, the black Painted surface showed the lowest temperature that is lower than the ambient temperature. The maximum radiant cooling temperature difference, which is ambient temperature minus plate temperature, observed is about 5 K.

도심지의 온열성상에 관한 연구 - 공조배열량의 감소에 따른 도심지 온열환경의 변화 - (Study on Thermal Property in Urban Area - Quantitative Estimation of Heat Island in Urban area using the Simple Urban Canopy Model -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1190-1196
    • /
    • 2004
  • Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we propose numerical model in order to analyze quantitative effects of building environmental factors on the heat island phenomenon in urban area. In this paper, we propose a predicting model to analyze the heat island phenomenon quantitatively. Using this model, numerical simulation is performed in order to analyze quantitative effects of many factor on the heat island phenomenon.

건조방법별 알팔파와 봄 연맥의 건초조제 효과 (Effect of Drying Methods on the Field Drying Rate and Quality of Alfalfa and Spring Oats Hay)

  • 서성;김종근;정의수;이종경;김원호;신동은
    • 한국초지조사료학회지
    • /
    • 제21권2호
    • /
    • pp.67-74
    • /
    • 2001
  • 본 시험은 봄철 속정건조에 의한 건조효과와 건초품질을 구명하여 양질의 건초를 조제코자, 알팔파(Vernal)과 연맥(Swan)을 공시하여 건조방법(건조제, conditioning, 대구조)을 달리하여 1997년 봄 수원 축산기술연구소에서 수행되었다. 수확시기는 6월 3일로 얄팔파는 개화초기, 연액은 춤수기였으며, 화학제인 건조제는 $KCO_2$ 2%를 수확직선 처리 하였고, 물리적인 conditioning은 모델 GMR 2800 trail-type mower conditioner를 사용하였다. 포장건조후 각형 곤포를 조제하였으며, 건조의 외관평가와 사료가치는 2개월간 보관저장후 분석.평가하였고, 시기별 식물체의 수분 함량은 포장상태에서 양파망을 이용 조사하였다. 건조방법별 건조속도는 conditioning구에서 우수 하였고, 전반적으로 건조제 처리효과는 낮았다. conditioning 처리시 건초조제 가능일수는 3일 정도로 건조제 처리구나 대조구에 비해 1일 이상 포장 건조기간 단축효과가 있었다. 건초의 건물손실은 알팔파와 연맥 모두 conditioning구에서 적었으며. 달관평가에서도 conditioning구에서 가장 우수하였다. 건초의 화학성분 평가에서 사료가치는 수확당시에 비해 크게 낮았는데, 이는 건조기간중 강우(7.8mm)와 저장기간중 가용성 당류의 손실에 의한 것으로 추정되며 대조구에 비해 conditioning구에서 ADF와 NDF 함량이 다소 낮고 건물소화율은 약간 높은 경향을 보였다. 이상의 결과로서 알팔파와 본 연맥의 건초조제 시 포장 건조기간 단축과 품질향상을 위해서는 mower condition$\varepsilon$r 사용이 가장 바람직하였으며, 건조제 처리효과는 없었고, 전반적으로 알팔파 건초의 품질이 본 연맥에 비해 우수하였다.

  • PDF

내부발열의 확률적 성상을 고려한 슬래브축냉의 최적제어 (A Study on Optimal Control of Slab Cooling Storage Considering Stochastic Properties of Internal Heat Generation)

  • 정재훈
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.313-320
    • /
    • 2015
  • In this paper, a method to obtain the probability distribution of room temperature and cooling load is presented, when the internal heat generation is applied to the system as a disturbance in the air conditioning system with slab cooling storage. The probability distribution of room temperature and the cooling load due to the disturbance were examined in one room of an office building. When considering only the electric power consumption as a probability component, it was found that the effect on room temperature and cooling load is small, because the probability component of the measured electric power consumption in the building is small. On the other hand, when considering the stochastic fluctuations of electric power consumption together with the heat generated by human bodies, the mean value of the cooling load was about 2,300 W and the ratio of the standard deviations was 19% (10 o'clock in second day). It was revealed that the stochastic effects of internal heat generation acting on the air conditioning system with slab cooling storage are not small.