• Title/Summary/Keyword: Condition Monitoring System

Search Result 1,226, Processing Time 0.036 seconds

A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux (축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.132-137
    • /
    • 2006
  • The second part of paper related rotor failure is to evaluate that the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algorithm for the various fault in the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency domain to detect the failure of the motor. Specific signature can be described in tin and frequency domain for each fault of the motor. The experimental test found that the rotor failures - broken rotor bar, broken end ing and rotor eccentricity, could be detected from the spectrum with high resolution. The method of detecting the rotor fault was found by analysing the specific frequency and the sideband of the rotor bar pass frequency from axial leakage flux spectrum. In addition the optimal flux coil and measuring equipment for the axial leakage flux measurement was verified and the diagnostic method for the detection of the rotor related failure was developed.

A Study on the Acoustic Absorption Panel by the Theory of Resonator (공명 원리를 이용한 흡음벽에 관한 연구)

  • Yu, Young-Hun;Yi, Jong-Keun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.125-129
    • /
    • 2006
  • It is very important to remove the noise levels made by an electric home appliance and machines they are located in the auditory region. The noise of ship engine room is known as it is not easy to lower so the working environment of the engine room is the worst condition because the improvement for the noise seemed insignificant and the hearing loss is occurred. As the monitoring equipment and an intelligent control system are improved rapidly the main engine of the ship can be enclosed with an acoustic barrier and any other absorbtion equipment. In this study, the sound absorbtion barrier is experimentally researched by change the volume and the length of the neck for the Helmholtz resonator as the resonator can absorb the noise effectively.

  • PDF

Detection of fluorescence from soils contaminated with monoaromatic hydrocarbons (유류 오염 토양에서의 단일방향족 탄화수소 농도 측정을 위한 자외선 형광 분석에 관한 연구)

  • 김우진;박재우;이주인
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.35-44
    • /
    • 2002
  • In order to determine the contamination of the aromatic hydrocarbons in soil, a fiber-optic sensing technique with fluorescence detector has been proposed. Previous researches have shown that the optimal condition for detecting benzene, toluene, ethylbenzene, xylene (BTEX) was 260 nm /290 nm (excitation/emission wavelength). However, broader fluorescence spectra of BTEX-polluted soil sample ranging from 300 nm to 600 nm were observed. Additionally, the intensity of fluorescence increased with increasing BTEX concentration, which was conspicuous in the fine-particle soil, The overall results indicated that the suggested technique could be useful for in-situ monitoring system for subsurface oil-storage tank.

A Study on the Water Quality Relationship between Continuous Dam Discharge and Downstream in North Han River (북한강에 연속된 댐 구간 방류수와 하류 하천간 수질 관계 분석 연구)

  • Kim, Ji Won;Lee, Hye Won;Lee, Yong Seok;Choi, Jung Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.89-97
    • /
    • 2020
  • North Han River is a very unique type of water system, where Hwacheon, Chuncheon, Soyanggang, Euiam and Cheongpyeong Dams are located consecutively. These dams are operated differently in the amount of discharge and release schedule according to their structure and purpose of use. They have different water quality characteristics depending on external pollutant inflow and internal mixing condition. Therefore, this study investigated the relationship between the upper dam and down stream river with respect to water quality indicators, such as water temperature, electrical conductivity, BOD, COD, TN and TP of the North Han River. The similarities and correlations representing the relationship were analyzed by Pearson's correlation r and t-test. The data was taken from the Ministry of Environment's water quality monitoring from 1999 to 2018. The results show that water temperature and electrical conductivity of the dam and river are similar and correlated. However, it turned out that there was no similarities and correlations in BOD, COD, TN and TP that are significantly affected by subaqueous reaction mechanism. The results of this study present the impact of the dam on the water quality of North Han River, which can be used as useful data for management of water quality.

Mode identifiability of a cable-stayed bridge based on a Bayesian method

  • Zhang, Feng-Liang;Ni, Yi-Qing;Ni, Yan-Chun
    • Smart Structures and Systems
    • /
    • v.17 no.3
    • /
    • pp.471-489
    • /
    • 2016
  • Modal identification based on ambient vibration data has attracted extensive attention in the past few decades. Since the excitation for ambient vibration tests is mainly from the environmental effects such as wind and traffic loading and no artificial excitation is applied, the signal to noise (s/n) ratio of the data acquired plays an important role in mode identifiability. Under ambient vibration conditions, certain modes may not be identifiable due to a low s/n ratio. This paper presents a study on the mode identifiability of an instrumented cable-stayed bridge with the use of acceleration response data measured by a long-term structural health monitoring system. A recently developed fast Bayesian FFT method is utilized to perform output-only modal identification. In addition to identifying the most probable values (MPVs) of modal parameters, the associated posterior uncertainties can be obtained by this method. Likewise, the power spectral density of modal force can be identified, and thus it is possible to obtain the modal s/n ratio. This provides an efficient way to investigate the mode identifiability. Three groups of data are utilized in this study: the first one is 10 data sets including six collected under normal wind conditions and four collected during typhoons; the second one is three data sets with wind speeds of about 7.5 m/s; and the third one is some blind data. The first two groups of data are used to perform ambient modal identification and help to estimate a critical value of the s/n ratio above which the deficient mode is identifiable, while the third group of data is used to perform verification. A couple of fundamental modes are identified, including the ones in the vertical and transverse directions respectively and coupled in both directions. The uncertainty and s/n ratio of the deficient mode are investigated and discussed. A critical value of the modal s/n ratio is suggested to evaluate the mode identifiability of the deficient mode. The work presented in this paper could provide a base for the vibration-based condition assessment in future.

A Study on Health Management System Based on Smart TV for Wellness Service (웰니스 서비스를 위한 스마트 TV 기반 건강관리시스템에 관한 연구)

  • Heo, Sung-Uk;Kang, Sung-In;Kwon, Oh-Hyun;Choi, Sung-Wook;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2615-2620
    • /
    • 2013
  • Recently consumers pursue optimized health condition and high leveled quality of life through active promotion and prevention activity of health as the importance of health during daily life is emerged to meet the demand of aging society. Thus healthcare service is evolved into smart healthcare stage using various type of smart devices depending upon the needs of consumers. However the connectivity and interoperability among individual medical devices and smart devices are insufficient, thus data accumulation through individual medical devices is also insufficient. This thesis suggest the methodology to establish the connection among Bluetooth HDP and individual medical devices based on smart TV in addition to the monitoring of biometrics.

Basic Investigation into the Validity of Thermal Analysis of 18650 Li-ion Battery Pack Using CFD Simulation (CFD 해석을 적용한 18650 리튬-이온 배터리 팩의 열 해석 신뢰도 기초 분석)

  • SIM, CHANG-HWI;KIM, HAN-SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.489-497
    • /
    • 2020
  • The Li-ion battery is considered to be one of the potential power sources for electric vehicles. In fact, the efficiency, reliability, and cycle life of Li-ion batteries are highly influenced by their thermal conditions. Therefore, a novel thermal management system is highly required to simultaneously achieve high performance and long life of the battery pack. Basically, thermal modeling is a key issue for the novel thermal management of Li-ion battery systems. In this paper, as a basic study for battery thermal modeling, temperature distributions inside the simple Li-ion battery pack (comprises of nine 18650 Li-ion batteries) under a 1C discharging condition were investigated using measurement and computational fluid dynamics (CFD) simulation approaches. The heat flux boundary conditions of battery cells for the CFD thermal analysis of battery pack were provided by the measurement of single battery cell temperature. The temperature distribution inside the battery pack were compared at six monitoring locations. Results show that the accurate estimation of heat flux at the surface of single cylindrical battery is paramount to the prediction of temperature distributions inside the Li-ion battery under various discharging conditions (C-rates). It is considered that the research approach for the estimation of temperature distribution used in this study can be used as a basic tool to understand the thermal behavior of Li-ion battery pack for the construction of effective battery thermal management systems.

Oxygen Consumption in Nile Tilapia, Oreochromis niloticus, in Relation to Body Weight and Water Temperature (나일틸라피아, Oreochromis niloticus의 어체중 및 수온에 따른 산소 소비량)

  • 김유희;조재윤
    • Journal of Aquaculture
    • /
    • v.12 no.3
    • /
    • pp.247-254
    • /
    • 1999
  • Changes of oxygen consumption of Nile tilapia in relation to different body sizes(average body weight 4 g, 40 g, 120 g and 400 g) and water temperatures ($20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$) were investigated by a continuous oxygen monitoring system. Mean oxygen consumption of 4 g, 40 g, 120 g and 400 g Nile tilapia at $20^{\circ}C$ were 318.8, 214.9, 84.1 and 69.4 mg $O_2$/kg fish/hr and that at $25^{\circ}C$ were 435.2, 345.9, 151.5 and 115.9 mg $O_2$/kg fish/hr, and that at $30^{\circ}C$ were 611.1, 538.4, 320.8, and 236.0 mg $O_2$/kg fish/hr, respectively. Oxygen consumption per unit body weight tended to decrease exponentially at all temperatures (P<0.05) as body weigth of the fish increased. Oxygen consumption of this fish at $25^{\circ}C$ was $1.61\pm0.18$ times higher than that at $20^{\circ}C$ and oxygen consumption at $30^{\circ}C$ was $1.53\pm0.27$ times higher than that at $25^{\circ}C$. Oxygen consumption per unit body weight linearly increased with the water temperature increased. Also, oxygen consumption of this fish during day time was higher than that during night time at 12L:12D day light condition. The differences between maximum and minimum daily oxygen consumption of this fish increased with the water temperature increased.

  • PDF

A Study on Design of Offshore Meteorological Tower (해상기상탑 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;Park, Tae-Sik;Jeong, Moon-Seon;Joo, Hyo-Joon;Kwon, O-Soon;Kwag, Dae-Jin;Jeong, Gwon-Seong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.60-65
    • /
    • 2014
  • A meteorological(met) tower is the first structure installed during the planning stages of offshore wind farm. The purpose of this paper is to design the met tower with tripod bucket type support structure and to install the sensors. The support structure consist of a central steel shaft connected to three cylindrical steel suction buckets which is more cheaper than monopile or jacket type. And the remote wind condition sensors and marine monitoring equipment, including adcp, pressure type tide gauge, wave height sensors, and scour sensors, remote power supply are installed. The manufactured met tower constructed on sea area which is in front of Gasa island. All of functions of met tower showed normal operation conditions and the wind data got by remote data collection system successfully.

A Development of Expected Loss Control Chart Using Reflected Normal Loss Function (역정규 손실함수를 이용한 기대손실 관리도의 개발)

  • Kim, Dong-Hyuk;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.2
    • /
    • pp.37-45
    • /
    • 2016
  • Control chart is representative tools of statistical process control (SPC). It is a graph that plotting the characteristic values from the process. It has two steps (or Phase). First step is a procedure for finding a process parameters. It is called Phase I. This step is to find the process parameters by using data obtained from in-controlled process. It is a step that the standard value was not determined. Another step is monitoring process by already known process parameters from Phase I. It is called Phase II. These control chart is the process quality characteristic value for management, which is plotted dot whether the existence within the control limit or not. But, this is not given information about the economic loss that occurs when a product characteristic value does not match the target value. In order to meet the customer needs, company not only consider stability of the process variation but also produce the product that is meet the target value. Taguchi's quadratic loss function is include information about economic loss that occurred by the mismatch the target value. However, Taguchi's quadratic loss function is very simple quadratic curve. It is difficult to realistically reflect the increased amount of loss that due to a deviation from the target value. Also, it can be well explained by only on condition that the normal process. Spiring proposed an alternative loss function that called reflected normal loss function (RNLF). In this paper, we design a new control chart for overcome these disadvantage by using the Spiring's RNLF. And we demonstrate effectiveness of new control chart by comparing its average run length (ARL) with ${\bar{x}}-R$ control chart and expected loss control chart (ELCC).