흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션 (Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump)

  • 박윤철;민만기
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

얇은 렌즈 조합을 이용한 집속 렌즈 시스템 설계 (Design of a Condenser Lens System using a Thin Lens Combination)

  • 임선종;최지연
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.517-522
    • /
    • 2011
  • Most of SEM is double condenser lens system. Two condenser lenses are required to provide the high demagnification ratios necessary for forming nanometer probes. The thin lens concept provides a highly useful basis for preliminary calculations in a broad range of situations. It is an easy way to understand the electron beam paths in column. Demagnification is easily calculated by this method. In this paper, we present design processes for condenser lens's demagnification by using thin lens combination model. Also, we verify the reliability of our design processes by comparing the modeled demagnification with these of corrected condenser lens.

콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계 (A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE)

  • 김화종;이상찬;오응종;이희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석 (A Study on Condenser Characteristics at the Series Connection of Condenser and Reactor Under Voltage Unbalance)

  • 김일중;김종겸;박영진;김성헌
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.325-329
    • /
    • 2010
  • Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.

응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.

냉장고 응축기의 전열성능에 대한 CFD 해석 (CFD ANALYSIS ON HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER)

  • 유성수;황도연;이명수;한병윤;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.56-62
    • /
    • 2009
  • In this study, the heat transfer and flow field of a condenser used for a Kim-chi refrigerator is analysed with numerical method. Main objective is to present the basic data for designing a new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As analysis parameters, the effect of condenser geometry and air velocity was investigated. For validation of the numerical calculations, the results were compared with the experimental ones. The heat transfer rates for both results were consistent with each other by maximum 5 % error. Based on this comparison, the numerical analysis was done with some modifications. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.

전압원인버터방식 송전용 무효전력보상기의 제어시스템 설계 (Control System Design for Self-Commutated Static Var Compensator)

  • 한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.89-92
    • /
    • 1996
  • This paper describes a detailed simulation model of the static condenser (STATCON) to analyze the dynamic interaction with the ac transmission line. The static condenser was represented by a 12-pulse voltage-source inverter sharing an energy storage dc capacitor. The voltage-source inverter consists of two 6-pulse bridges modeled with ideal gate-turn-off switches. The control system for the static condenser was designed through a mathematical model deduced from the equivalent circuit. Simulation results show that the conceived model is very effective to analyze the dynamic interaction between the static condenser and the ac transmission system.

  • PDF

영광 #1/2 복수기 누수부 보수공사 (Yeonggwang #1/2 steam condenser leakage repair works)

  • 이상철;공창식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.117-119
    • /
    • 2003
  • Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.

  • PDF

대기 조건에 따른 공랭식 응축기 성능 저하 개선 연구 (Study on Performance Improvement Air Cooled Condenser Considering Ambient Condition)

  • 차훈;류광년;김정래
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권3호
    • /
    • pp.201-207
    • /
    • 2015
  • 공랭식 응축기(ACC, Air Cooled Condenser)는 공기를 냉매로 이용하여 저압 스팀을 응축하는 설비로써 사막이나 내륙 등 물이 부족한 지역에서 주로 사용된다. 공랭식 응축기의 성능은 풍속이나 대기온도와 같은 외기 조건에 의해 크게 영향을 받으므로 성능 저하 개선을 위해 여러 장치들이 설치된다. 본 연구에서는 풍속에 의한 ACC 성능 변화를 확인하고 윈드 스크린에 의한 성능 개선 효과를 분석하기 위해 CFD 해석을 수행하였다. CFD 는 질량 보존, 운동량 보존 등 미분방정식을 차분방정식으로 변환하여 검사 체적에 대해 속도, 온도 등을 계산하는 기법이다. 풍속이 3m/s 에서 7m/s 로 상승할 때, ACC 에 설치된 팬 공급 유량은 약 15.76% 감소하며 ACC 유입 공기 온도는 $5.55^{\circ}C$ 증가한다. 윈드 스크린을 적절히 설치한 경우, 풍속이 7m/s 이고 윈드 스크린이 설치되지 않은 경우에 비해 팬 공급 유량이 약 5.18% 증가하며 ACC 유입 공기 온도 상승은 $2.08^{\circ}C$ 감소하는 효과가 있다.

MLCC 출력 콘덴서를 이용한 LED 구동드라이브 설계 (Design of LED Drive using MLCC Output Capacitor)

  • 한만승;이상훈;조수억;박성준
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.448-456
    • /
    • 2011
  • 최근 디지털 광원으로서 각광받고 있는 고출력 LED(Light Emitting Diode)는 저소비전력과 장수명 그리고 점 소등 속도도 빨라서 고출력 LED의 효율을 향상시켜 일반 조명용으로 사용하려는 노력이 두드러지고 있다. 본 논문에서는 온도변화에 따른 전압 변동분만을 출력 콘덴서에 저장함으로서 출력 측에 사용하던 전해 콘덴서를 전압용량이 작고 수명이 긴 MLCC(Multi-Layer Ceramic Capacitor) 사용이 가능한 LED 구동 드라이브를 제안하고자 한다. 제안된 LED 구동 드라이브는 기존의 부스트 DC/DC 컨버터의 기본 토폴로지에서 출력 콘덴서를 입력 전원과 직렬로 연결하여 LED 광원의 온도변화에 따른 전압 변동분만을 출력 콘덴서에 저장함으로서 출력 콘덴서로 기존수명이 낮은 전해 콘덴서 대신 전력 손실이 적고 수명이 긴 MLCC 사용이 가능하게 된다.