• 제목/요약/키워드: Concrete-Filled Circular Steel Tube Column

검색결과 72건 처리시간 0.022초

CFT 기둥의 장기거동 특성에 관한 연구 (The Long-term Behavior of CFT-Column)

  • 권승희;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.579-582
    • /
    • 1999
  • This paper represents the results of experiments designed to investigate the time-dependent response of concrete and steel tube in circular concrete-filled steel tubes, as are deployed extensively in high-rise building construction. The experiments were performed for creep of concrete and CFT column specimens with three loading cases. The creep coefficient and specific creep(unit creep) obtained from the test results were used for estimating and comparing the time-dependent response of each case. From these analyses, it is show that CFT-column has many merits for long-term behavior.

  • PDF

Prediction of ultimate load capacity of concrete-filled steel tube columns using multivariate adaptive regression splines (MARS)

  • Avci-Karatas, Cigdem
    • Steel and Composite Structures
    • /
    • 제33권4호
    • /
    • pp.583-594
    • /
    • 2019
  • In the areas highly exposed to earthquakes, concrete-filled steel tube columns (CFSTCs) are known to provide superior structural aspects such as (i) high strength for good seismic performance (ii) high ductility (iii) enhanced energy absorption (iv) confining pressure to concrete, (v) high section modulus, etc. Numerous studies were reported on behavior of CFSTCs under axial compression loadings. This paper presents an analytical model to predict ultimate load capacity of CFSTCs with circular sections under axial load by using multivariate adaptive regression splines (MARS). MARS is a nonlinear and non-parametric regression methodology. After careful study of literature, 150 comprehensive experimental data presented in the previous studies were examined to prepare a data set and the dependent variables such as geometrical and mechanical properties of circular CFST system have been identified. Basically, MARS model establishes a relation between predictors and dependent variables. Separate regression lines can be formed through the concept of divide and conquers strategy. About 70% of the consolidated data has been used for development of model and the rest of the data has been used for validation of the model. Proper care has been taken such that the input data consists of all ranges of variables. From the studies, it is noted that the predicted ultimate axial load capacity of CFSTCs is found to match with the corresponding experimental observations of literature.

Experimental and numerical analysis of seismic behaviour for recycled aggregate concrete filled circular steel tube frames

  • Xianggang Zhang;Gaoqiang Zhou;Xuyan Liu;Yuhui Fan;Ercong Meng;Junna Yang;Yajun Huang
    • Computers and Concrete
    • /
    • 제31권6호
    • /
    • pp.537-543
    • /
    • 2023
  • To study the seismic behavior of recycled aggregate concrete filled circular steel tube (RACFCST) frames, the seismic behavior experiment of RACFCST frame was carried out to measure the hysteresis curve, skeleton curve and other seismic behavior indexes. Moreover, based on the experimental study, a feasible numerical analysis model was established to analyze the finite element parameters of 8 RACFCST frame specimens, and the influence of different variation parameters on the seismic behavior index for RACFCST frame was revealed. The results showed that the skeleton curve of specimens under different axial compression ratios were divided into three stages: elastic stage, elastic-plastic stage and descending stage, and the descending stage was relatively stable, indicating that the specimen had stronger deformation capacity in the descending stage. With the increase of axial compression ratio, the peak bearing capacity of all specimens reduced gradually, and the reduction was less than 5%. With the decrease of beam-column linear stiffness ratio, the peak bearing capacity decreased gradually. With the decrease of yield bending moment ratio of beam-column, the peak bearing capacity decreased gradually, and the decreasing rate of peak bearing capacity gradually accelerated. In addition, compared with the axial compression ratio, the beam-column linear stiffness ratio and the yield bending moment ratio of beam-column had a more significant influence on the peak bearing capacity of RACFCST frame.

조립각형 CFT 기둥의 용접크기 결정을 위한 수압실험 및 해석 (Water pressure Test and analysis for Welding Thickness Decision of New Cold-formed Type Concrete Filled Tubular Square Column)

  • 이성희;김선희;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.515-526
    • /
    • 2009
  • 콘크리트 충전강관에 사용되는 강관의 제작법은 재단된 4장의 플레이트를 모서리에서 용접하는 일반강관 제작법과, ㄷ형으로 절곡성형과정을 거쳐 2-Seam으로 용접하는 제작방법, 그리고 원형강관을 압축하여 4각형태로 만드는 방법등이 일반적으로 사용되며, 강관제작에 사용되는 용접방법과 용접량의 선택은 강관 제작비용에 큰 부분을 차지하고 있다. 새로운 제작형식으로 개발된 각형강관은 4장의 플레이트를 ㄱ형으로 절곡성형한 후 강관 폭의 중앙에서 4-Seam Flare 용접하는 방식이다. 본 연구에서는 새로운 제작형식의 CFT 각형 기둥에 대하여 용접량 평가를 위한 실험방법을 제시하고, 강관 제작법, 강관두께 및 용접량을 변수로 총 6개의 실험체를 제작하여 구조실험 및 해석을 수행하여 강관내부의 수압에 따른 강관의 거동을 평가하였다.

Investigations of different steel layouts on the seismic behavior of transition steel-concrete composite connections

  • Qi, Liangjie;Xue, Jianyang;Zhai, Lei
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.173-185
    • /
    • 2019
  • This article presents a comparative study of the effect of steel layouts on the seismic behavior of transition steel-concrete composite connections, both experimental and analytical investigations of concrete filled steel tube-reinforced concrete (CFST-RC) and steel reinforecd concrete-reinforced concrete (SRC-RC) structures were conducted. The steel-concrete composite connections were subjected to combined constant axial load and lateral cyclic displacements. Tests were carried out on four full-scale connections extracted from a real project engineering with different levels of axial force. The effect of steel layouts on the mechanical behavior of the transition connections was evaluated by failure modes, hysteretic behavior, backbone curves, displacement ductility, energy dissipation capacity and stiffness degradation. Test results showed that different steel layouts led to significantly different failure modes. For CFST-RC transition specimens, the circular cracks of the concrete at the RC column base was followed by steel yielding at the bottom of the CFST column. While uncoordinated deformation could be observed between SRC and RC columns in SRC-RC transition specimens, the crushing and peeling damage of unconfined concrete at the SRC column base was more serious. The existences of I-shape steel and steel tube avoided the pinching phenomenon on the hysteresis curve, which was different from the hysteresis curve of the general reinforced concrete column. The hysteresis loops were spindle-shaped, indicating excellent seismic performance for these transition composite connections. The average values of equivalent viscous damping coefficients of the four specimens are 0.123, 0.186 and 0.304 corresponding to the yielding point, peak point and ultimate point, respectively. Those values demonstrate that the transition steel-concrete composite connections have great energy dissipating capacity. Based on the experimental research, a high-fidelity ABAQUS model was established to further study the influence of concrete strength, steel grade and longitudinal reinforcement ratio on the mechanical behavior of transition composite connections.

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

The efficiency of passive confinement in CFT columns

  • Johansson, Mathias
    • Steel and Composite Structures
    • /
    • 제2권5호
    • /
    • pp.379-396
    • /
    • 2002
  • The paper describes the mechanical behavior of short concrete-filled steel tube (CFT) columns with circular section. The efficiency of the steel tube in confining the concrete core depending on concrete strength and the steel tube thickness was examined. Fifteen columns were tested to failure under concentric axial loading. Furthermore, a mechanical model based on the interaction between the concrete core and the steel tube was developed. The model employs a volumetric strain history for the concrete, characterized by the level of applied confining stress. The situation of passive confinement is accounted for by an incremental procedure, which continuously updates the confining stress. The post-yield behavior of the columns is greatly influenced by the confinement level and is related to the efficiency of the steel tube in confining the concrete core. It is possible to classify the post-yield behavior into three categories: strain softening, perfectly plastic and strain hardening behavior. The softening behavior, which is due to a shear plane failure in the concrete core, was found for some of the CFT columns with high-strength concrete. Nevertheless, with a CFT column, it is possible to use high-strength concrete to obtain higher load resistance and still achieve a good ductile behavior.

원형강관으로 구속된 콘크리트의 역학적 거동 특성에 관한 연구 (A Study on Properties of Mechanical Behaviors of Concrete Confined by Circular Steel Tube)

  • 박정민;김화중
    • 콘크리트학회지
    • /
    • 제7권3호
    • /
    • pp.199-210
    • /
    • 1995
  • 충전형 강관콘크리트 구조는 강관과 콘크리트 두 재료의 이질적인 재료특성을 상호 보완적으로 발휘하여 구조적 성능향상을 꾀한 것으로서 제구조 특성상 우수한 구조형식이라 할 수 있다. 강관으로 구속된 콘크리트가 중심축력을 받게 되면 내부의 콘크리트는 압괴에 의한 체적 팽창을 외부의 강관에 의해 구속 받게 되므로 3축 압축응력 상태로 되어 압축강도가 증대된다. 또한 콘크리트의 압괴에 의한 탈락 현상이 방지되므로서 단면의 결손이 없어져 내력 저하가 작아진다는 잇점을 가진다. 따라서 본 연구에서는 원형강관으로 구속된 내부 콘크리트의 구조적 거동 특성을 규명하기 위한 것으로서 폭두께비와 충전 콘크리트의 강도를 주요 변수로 하여 일련의 실험을 통하여 강관으로 구속(3축 응력)된 콘크리트의 구조적 거동 특성을 고찰하였다. 일련의 실험을 통하여 얻어진 결론을 요약하면 다음과 같다. (1)강관에 의한 콘크리트의 구속효과는 강관의 폭두께비와 충전 콘크리트의 강도가 낮을수록 현저하며, 원형강관으로 구속된 내부 콘크리트는 최대내력시의 변형능력에 있어서 횡방향 구속이 없는 콘크리트보다 4~7배 정도까지 증대시켜 연성효과를 높일 수 있을 것으로 기대된다. (2)콘크리트의 구속계수를 이용하여 강관으로 구속된 내부 콘크리트의 강도와 콘트리트 충전강관 기둥의 최대내력을 산정할 수 있는 식을 제시하였다.

Finite element analysis of CFT columns subjected to pure bending moment

  • Hu, H.T.;Su, F.C.;Elchalakani, M.
    • Steel and Composite Structures
    • /
    • 제10권5호
    • /
    • pp.415-428
    • /
    • 2010
  • Proper material constitutive models for concrete-filled tube (CFT) columns of circular cross section and subjected to pure bending moment are proposed. These material models are implemented into the Abaqus finite element program and verified against experimental data. It has been shown that the steel tube does not provide good confining effect to the concrete core when the CFT columns is subjected to pure bending moment. When the diameter-to-thickness ratio of the CFT columns is small, the behavior of the CFT column is the same as the steel tube without a concrete core.

Buckling resistance of axially loaded square concrete-filled double steel tubular columns

  • Ci, Junchang;Ahmed, Mizan;Tran, Viet-Linh;Jia, Hong;Chen, Shicai;Nguyen, Tan N.
    • Steel and Composite Structures
    • /
    • 제43권6호
    • /
    • pp.689-706
    • /
    • 2022
  • Thin-walled square concrete-filled double steel tubular (CFDST) columns composed of the inner circular tube filled with concrete can be used to carry the large axial loads or strengthen existing CFST columns in composite constructions. This paper reports an experimental program carried out on short square CFDST columns loaded concentrically. The influences of important column parameters on the post-buckling performance of such columns are investigated. Test results exhibit that the inner circular tube significantly improves the ultimate loads and the ductility of such columns compared to conventional concrete-filled steel tubular (CFST) and double-skin CFST (DCFST) columns with an inner void. A mathematical model developed is used to simulate the ultimate strengths and load-strain curves of such columns loaded axially. Furthermore, the ultimate strengths of such columns are predicted using existing codified design models for conventional CFST columns as well as the formulas proposed by previous researchers and compared against a large database comprising 500 CFDST columns. Lastly, an accurate artificial neural network model is developed for the practical applications of such columns under axial loading.