• Title/Summary/Keyword: Concrete slab bridge

Search Result 297, Processing Time 0.019 seconds

Design Bending Moments For Long-Span Slab On a Composite Two-Girder Bridge (2거더 강합성교를 위한 장지간 바닥판 설계 휨모멘트)

  • Yoon, Hye-Jin;Joh, Chang-Bin;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.754-757
    • /
    • 2004
  • This study was performed to propose design bending moment formula for long-span slab on a composite two-girder bridge. FEM models representing slab spaning between 4m and 12m were analyzed, and parameters such as girder flexibility and orthotropy of slab were considered. By regression of the parametric analyses results, the moment formula that can predict the design moment with reasonable margin of safety and correctness was developed. The research also showed that the design bending moment from Korean Bridge Design Code overestimated the design moment for the span length under gm, and underestimated for the span length over 9m.

  • PDF

Behavior Properties of Bridge by Non Destructive and Loading Test (비파괴 및 재하시험에 의한 노후 교량의 거동특성)

  • Min, Jeong-Ki;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.61-71
    • /
    • 2004
  • The performance evaluation and deflection of 3 spans concrete simplicity slab bridge analyzed by non-destructive and loading test. Compressive strength of slab and pier appeared in the range of each 353∼366 kgf/$cm^2$ and 152∼215 kgf/$cm^2$ in rebound number test. Also, it appeared that concrete quality of slab was good after performance improvement. The average compressive strength of slab by core picking appeared 229 kg/$cm^2$. In reinforcing bar arrangement test of span and member, it appeared that horizontal and vertical reinforcing bar was arranged to fixed interval. The value of calculation deflection that carried structural analysis with deflection analysis wave in static loading test appeared higher than that of experimental deflection and it appeared that hardness of this bridge was good. Maximum impact factor that estimated from deflection by running speed in dynamic loading test appeared by 0.216 in 10 km/hr running speed.

A Study on the Safety Assessment of Curved Hollow RC Slab Bridge Structures (곡선형 RC 중공 슬래브교의 안전성 평가 사례 연구)

  • Chai, Won-Kyu;Jo, Byung-Wan;Kim, Kwang-Il
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.96-100
    • /
    • 2006
  • In this thesis, the crack investigation, the damage investigation, the drawing check, and the structural analysis were performed on a curved hollow RC(reinforced concrete) slab bridge structure to assess the structural safety of that. From the crack investigation result, main reason of crack occurrence is guessed with travelling of the large truck. Therefore reinforcement of slab structure is necessary by using the steel plate. When structural analysis, the straight beam model, the curved beam model, and the curved plate model is used. From the results of structural analysis for curved hollow RC slab bridge, the maximum bending moment and the maximum shear force was not a difference in each models. But the vertical displacement of mid span using the curved beam model was greater than that using the other models.

A Study on Flexural Behavior of Precast Prestressed Concrete Hollow Slab Bridge (조립식 PSC 중공슬래브교의 휨거동에 관한 연구)

  • Kim, Ki-Yong;Song, Ha-Won;Kim, Ho-Jin;Byun, Keun-Joo;Kim, Yon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.524-527
    • /
    • 2004
  • Recently, precast concrete products have been increasingly used in the construction of bridges except for special bridges like long-span bridge due to their easy and high-quality construction. Specially the use of precast prestressed concrete hollow box slab bridges is also increased due to the merits in their construction. Thus, an experimental evaluation of flexural behavior of the precast PSC hollow box slab bridges and a development of effective analytical technique for the behavior are necessary. For the development, experimental study on the flexural behavior of the precast bridges up to ultimate states is needed. In this study, two full-scale precast PSC hollow box slab girders are manufactured and full-scale flexural failure tests of the girders subjected to cyclic loading are carried out. For the failure analysis of the girders, the so-called volume control method is applied to finite element analysis of the precast PSC hollow box slab girders discretized using multi-layered shell elements. The analytical results by the volume control method is verified by comparing with test results.

  • PDF

Evaluation of Durabilities in Ruined RC Bridge (철근콘크리트 철거교량의 내구성 평가)

  • 유환국;김국한;류금성;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.655-658
    • /
    • 1999
  • An experimental investigation on the ruined RC bridge with 30 years old has been conducted to estimate the durabilities. The ruined RC bridge estimated in this study was located at Kyung-Bu Express Way. First, concrete strength and durability characteristics such as concrete resistivity, chloride content were estimated. Second, it was to test reinforcing corrosion embedded in slab of bridge. And, third, tensile strength and yield strength of reinforcing bar corroded and not corroded were estimated. This bridge inspection provides the most common cause of defects and deterioration and the results of this inspections give more specific information than those of laboratory inspections do.

  • PDF

An Experimental study of External Prestress Strengthening Method for continuous bridges (외부강선을 이용한 연속교 보강공법의 실험적 연구)

  • Han, Man-Yup;Shin, Jae-Woo;Kang, Tae-Heon;Jin, Kyung-Suk;Kang, Sang-Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.117-120
    • /
    • 2006
  • This study is for the strengthening method of continuous bridge through external tendon strengthening that is the most general and effective among concrete bridge's strengthening method. Recently, it is numerous that slab's parts between spans have continuity for improving trafficable ability. However, in this case, slab would have a crack; bridge's durability would be damaged, and also it is too difficult to manage and maintain bridge due to the tensile strength of negative moment. Therefore, the purpose of this study is to demonstrate load-carrying through experiments and develop new external pre-stressing strengthening method for reinforcing continuous bridge.

  • PDF

A Comparative Study on the Performance Evaluation of Concrete Slab and Latex Modified Concrete for Bridge Deck Overlay (교면포장용 콘크리트 슬래브와 라텍스 개질 콘크리트포장의 피로성능평가에 대한 비교 연구)

  • Kim, Doo-Hwan;Lee, Ji-Hoon;Kim, Seong-Pil;Song, Kwan-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.88-94
    • /
    • 2012
  • In order to develop high performance concrete that overcome defects of asphalt and latex modified concrete for bridge deck overlay, this study aims to evaluate durability performance of concrete slab for bridge deck overlay. The present study is an exploratory research concerned with evaluation of two types of high performance concrete for bridge deck applications. This study is composed of a set of experiments, including static loading test and fatigue test and compared with data of defection, crack, concrete and steel strain. Also, experimental results were verified with analytical models by ABAQUS program. But overall behaviors of all specimens are comfortable, so those take sufficient load carrying capacity and high stiffness in cyclic load.

Shear behavior and analytical model of perfobond connectors

  • Zheng, Shuangjie;Liu, Yuqing;Yoda, Teruhiko;Lin, Weiwei
    • Steel and Composite Structures
    • /
    • v.20 no.1
    • /
    • pp.71-89
    • /
    • 2016
  • In steel and concrete composite girders, the load transfer between the steel beam and the concrete slab is commonly ensured by installing shear connectors. In this paper, to investigate the nonlinear behavior of perfobond connectors, a total of 60 push-out specimens were fabricated and tested with the variables for the hole diameter, the concrete strength, the thickness of concrete slab, the diameter, strength and existence of perforating rebar, the thickness, height and distance of perfobond ribs. The failure mode and the load-slip behavior of perfobond connectors were obtained. A theoretical model was put forward to express the load-slip relationship. Analytical formulas of shear capacity and peak slip were also proposed considering the interaction between the concrete dowel and the perforating rebar. The calculation results of the proposals agreed well with the experimental values.

Analysis of Bending Behavior of Skew Concrete Slab Bridges (콘크리트 슬래브 사교의 휨거동 해석)

  • 정성우;정재호;윤순종
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.409-414
    • /
    • 1998
  • In this paper, we present the results of finite element analyses pertaining to the mechanical behavior of simply supported skew concrete slab bridges. To investigate the bending behavior of skew concrete slab three skewed slabs are modelled with different plate aspect ratios. In each modelled skew plate, skew angles are varied from 0$^{\circ}$to 45$^{\circ}$ by 5$^{\circ}$interval. It is found that the support reactions at the obtuse corner are remarkably higher than the other support reactions. In the design of skew slab bridge bearings, the capacity of bearing installed at the obtuse corner should be very high or otherwise the spacing between the bearings at this corner must be adjusted appropriately to resist extra high reactions.

  • PDF

Longitudinal anti-cracking analysis for post-tensioned voided slab bridges

  • Zhou, Zhen;Meng, Shao-Ping;Liu, Zhao
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.459-473
    • /
    • 2012
  • Post-tensioned concrete voided slab girders are widely used in highway bridge constructions. To obtain greater section hollow rate and reduce the self-weight, the plate thickness of slab girders are designed to be small with the adoption of flat anchorage system. Since large prestress is applied to the anchor end section, it was found that longitudinal shear cracks are easy to occur along the voided slab girder. The reason is the existence of great shearing effect at the junction area between web and bottom (top) plate in the anchor end section. This paper focuses on the longitudinal anti-cracking problem at the anchor end of post-tensioned concrete voided slab girders. Two possible models for longitudinal anticracking analysis are proposed. Differential element analysis method is adopted to derive the solving formula of the critical cracking state, and then the practical analysis method for longitudinal anti-cracking is established. The influence of some factors on the longitudinal anti-cracking ability is studied. Results show that the section dimensions (thickness of bottom, web and top plate) and prestress eccentricity on web plate are the main factors that influence the anti-cracking ability. Moreover, the proposed method is applied into three engineering examples to make longitudinal anti-cracking verification for the girders. According to the verification results, the design improvements for these girders are determined.