• 제목/요약/키워드: Concrete lintel

검색결과 7건 처리시간 0.02초

인방형 강재댐퍼의 구조성능에 대한 실험적 연구 (Experimental Evaluation of the Seismic Performance for Lintel Beam Type Steel Damper)

  • 노경민;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.77-84
    • /
    • 2017
  • As an alternative to coupling beam in shear wall system, application of the damper which can dissipate energy is increasing. In this study, lintel beam type steel damper which is simple to construct and change depending on design load was proposed. Cyclic loading test was conducted to compare reinforced concrete coupling beam and lintel beam type steel damper. The test results showed that lintel beam type steel damper has higher initial stiffness and energy dissipation capacity than reinforced concrete coupling beam.

조적공사 인방보용 강재트러스 구조물에 관한 실험적 연구 - 아파트 기준층 문틀 상단 인방재를 중심으로 - (Experimental Study on Steel Truss Structure for Safety Lintel in Masonry Construction -Focusing on Door Frame Top Lintel at Typical Floor Apartment-)

  • 김영춘;유현동;최우종;정상무;강경식
    • 대한안전경영과학회지
    • /
    • 제15권3호
    • /
    • pp.29-35
    • /
    • 2013
  • The research is to verify by experiments whether the steel truss structure is able to withstand the load of cement bricks of upper part of a door for the safe use of lightweight steel truss structure instead of concrete lintel which is to be installed at upper part of door frame in building cement bricks for apartment construction. The steel truss is designed in order not to disturb bricks-building and the shape of structure was verified by bending test. According to experiments result, camber was applied to steel structure that enabled construction work to be improved and was proved effective for the prevention of accidents by cement bricks-building load test.

Dynamic behaviors of viscous damper on concrete archaized building with lintel-column joint

  • Xue, Jianyang;Dong, Jinshuang;Sui, Yan
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.409-419
    • /
    • 2017
  • In order to analyze the vibration control effect of viscous damper in the concrete archaized buildings with lintel-column joints under seismic action, 3 specimens were tested under dynamic excitation. Two specimens with viscous damper were defined as the controlled component and one specimen without viscous damper was specified as the non-controlled component. The loading process and failure patterns were obtained from the test results. The failure characteristics, skeleton curves and mechanical behavior such as the load-displacement hysteretic loops, load carrying capacity, degradation of strength and rigidity, ductility and energy dissipation of the joints were analyzed. The results indicate that the load-bearing capacity of the controlled component is significantly higher than that of the non-controlled component. The former component has an average increase of 27.4% in yield load and 22.4% in ultimate load, respectively. Meanwhile, the performance of displacement ductility and the ability of energy dissipation for the controlled component are superior to those of the non-controlled component as well. Compared with non-controlled component, equivalent viscous damping coefficients are improved by 27.3%-30.8%, the average increase is 29.0% at ultimate load for controlled component. All these results reflect that the seismic performance of the controlled component is significantly better than that of the non-controlled component. These researches are helpful for practical application of viscous damper in the concrete archaizing buildings with lintel-column joints.

RC벽식 부분구조의 반복 횡하중 거동에서의 축소모델 상사성 실험연구 (Experimental Study on the Similitude of Small-Scale Models in Cyclic Lateral Behaviors of RC Shear Wall Subassemblages)

  • 이한선;조창석;이상호;오상훈;박홍근
    • 콘크리트학회논문집
    • /
    • 제22권6호
    • /
    • pp.805-816
    • /
    • 2010
  • 축소모델의 지진모의실험을 위해서는 실물 실험체의 구조거동을 축소모델 실험체가 잘 모사하는지 상사성 확인이 필수적이다. 본 논문에서는 2층 RC 벽식구조 실험체의 반복 횡가력 실험을 통해 강도, 연성과 같은 전체거동과 휨, 전단, 들뜸과 같은 국부거동의 결과를 나타내었다. 인방보의 유무에 따른 3 : 5 실물 실험체와 1 : 7 축소모델 실험체를 비교 분석 하였으며, 1 : 7 축소모델 실험체가 실물 실험체의 전체거동과 국부거동에 대해서 대체로 잘 모사하고 있음을 확인하였다.

Shake table testing of confined adobe masonry structures

  • Khan, Faisal Zaman;Ahmad, Muhammad Ejaz;Ahmad, Naveed
    • Earthquakes and Structures
    • /
    • 제20권2호
    • /
    • pp.149-160
    • /
    • 2021
  • Buildings made using the locally available clay materials are amongst the least expensive forms of construction in many developing countries, and therefore, widely popular in remote areas. It is despite the fact that these low-strength masonry structures are vulnerable to seismic forces. Since transporting imported materials like cement and steel in areas inaccessible by motorable roads is challenging and financially unviable. This paper presents, and experimentally investigates, adobe masonry structures that utilize the abundantly available local clay materials with moderate use of imported materials like cement, aggregates, and steel. Shake-table tests were performed on two 1:3 reduce-scaled adobe masonry models for experimental seismic testing and verification. The model AM1 was confined with vertical lightly reinforced concrete columns provided at all corners and reinforced concrete horizontal bands (i.e., tie beams) provided at sill, lintel, and eave levels. The model AM2 was confined only with the horizontal bands provided at sill, lintel, and eave levels. The models were subjected to sinusoidal base motions for studying the damage evolution and response of the model under dynamic lateral loading. The lateral forcedeformation capacity curves for both models were developed and bi-linearized to compute the seismic response parameters: stiffness, strength, ductility, and response modification factor R. Seismic performance levels, story-drift, base shear coefficient, and the expected structural damages, were defined for both the models. Seismic performance assessment of the selected models was carried out using the lateral seismic force procedure to evaluate their safety in different seismic zones. The use of vertical columns in AM1 has shown a considerable increase in the lateral strength of the model in comparison to AM2. Although an R factor equal to 2.0 is recommended for both the models, AM1 has exhibited better seismic performance in all seismic zones due to its relatively high lateral strength in comparison to AM2.

Green Frame 접합방식 기초연구 (A Basic Research for Connection Type of Green Frame)

  • 김근호;주진규;임채연;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.171-172
    • /
    • 2011
  • Green column and green beam, key structural members of green frame, have the characteristics of post-lintel structure, thanks to the steel frame in the connection, enabling prompt and precise installation. The connection of green frame can be divided into 4 types, depending on its shape, and each type is associated with different characteristics and construction methods. Notably, as the connection between green columns have differing types and sequences of work, subject to the connection method in use, a connection method optimized for relevant site conditions need to be selected. Therefore, this study analyzed pros and cons of 4 different types of green frame connection methods. The results set forth herein will provide basic data for subsequent studies to comparatively analyze the performance and constructibility of different green frame connection methods.

  • PDF

근대건축 등록문화재의 보존 방안에 관한 연구 (A Study on the Preservation Method of Modern Registered Architectural Cultural Properties)

  • 신웅주;이상선
    • 한국농촌건축학회논문집
    • /
    • 제16권1호
    • /
    • pp.119-127
    • /
    • 2014
  • This study suggests institutional and methodological approaches for preservation of South Korea's registered cultural properties of modern architecture. The suggested approaches are as follows. First, in order to improve the current registration and preservation system for cultural properties, we need to employ both structure-based classification and style-based classification. Registration criteria for modern architecture properties need to include more detailed classification in terms of their structure: brick structure, steel concrete structure and post lintel structure. In terms of construction style, the properties need to be further classified into the western style, the traditional style and the Korean-western eclectic style. In addition, protection of registered cultural properties need to be achieved through legislation of a protection system. Second, while the current system sets out six methods for preservation of registered cultural properties of modern architecture, more specific preservation methods types and plans need to be continuously introduced. In particular, as for the method of partial preservation, the method needs to be further classified based on the usage of the relevant structure so as to allow for more diverse options. First, the 'Preservation by Interior Alteration' needs to be added to the category, where the exterior is preserved as it is and the interior is preserved through alteration. Also needs to be added the preservation method where the interior space is preserved as it is and the exterior space is altered, in case the finishing materials of the exterior has deteriorated. Third, if the records on registered cultural properties of modern architecture are to provide the functions of legal evidences regarding management of architectural cultural properties, sources of knowledge required for policy making and implementation and past management record for the future, each phase needs to be closely connected in an organic manner, and we need to establish a management system and plan that go beyond the relevant organizations. Fourth, in order to preserve South Korea's registered cultural properties of modern architecture in its original state, it is imperative to prepare separate criteria for registration of technicians with expertise on modern architecture, and train experts and technicians on modern architecture, which is distinguished from the traditional architecture.