• Title/Summary/Keyword: Concrete flange

Search Result 227, Processing Time 0.028 seconds

Behavior of Detensionable and Retensionable PSC Girder with Projected Flange (긴장력 조절이 가능한 PSC 거더의 거동에 관한 연구)

  • Nam, Jung-Min;Kim, Jin-Keun;Lee, Jong-Kwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.389-392
    • /
    • 2006
  • A In this paper, a new prestressed concrete girder system is presented which is designed using a detensionable and retensionable system. Experiments were carried out in order to comprehend the behavior of detensionable and retensionable prestressed concrete girder system. Tension control tests were performed for the detensionable and retensionable system followed by the static loading tests to check the applicability of the girder system. The test results were found in good agreement with the analytical results which clearly indicates the reliability of the concept of detensionable and retensionable prestress concrete girder with projected flange.

  • PDF

Further study on improvement on strain concentration in through-diaphragm connection

  • Qin, Ying;Zhang, Jingchen;Shi, Peng;Chen, Yifu;Xu, Yaohan;Shi, Zuozheng
    • Steel and Composite Structures
    • /
    • v.39 no.2
    • /
    • pp.135-148
    • /
    • 2021
  • Hollow structural section (HSS) columns have been increasingly popular due to their structural and architectural merits. However, practical difficulty lies in developing proper connections. The through-diaphragm connections are considered as suitable connection type that is widely adopted in Asian countries. However, the stress concentration occurs at the location connecting through-diaphragm and steel beam. Furthermore, the actual load path from the beam flange is not uniformly transferred to the HSS column as conventionally assumed. In this paper, tensile tests were further conducted on three additional specimens with beam flange plate to evaluate the load versus displacement response. The load-displacement curves, yield and ultimate capacity, ductility ratio were obtained. Furthermore, the strain development at different loading levels was discussed comprehensively. It is shown that the studied connection configuration significantly reduces the stress concentration. Meanwhile, simplified trilinear load-displacement analytical model for specimen under tensile load was presented. Good agreement was found between the theoretical and experimental results.

Elastic Buckling Characteristics of Plate Girder Web Panel (경량전철 2주형 판형교 복부판의 탄성좌굴 특성)

  • 황민오;성택룡;윤태양;이안호
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.344-351
    • /
    • 2000
  • In the design of plate girder web panels, it is required to evaluate accurately the elastic buckling strength under pure shear, pure bending and combined bending and shear. Currently, elastic buckling coefficients of web panels stiffened by transverse intermediate stiffeners are determined by assuming conservatively that web panels are simply supported at the juncture between the flange and web. However, depending upon the geometry and the properties of the plate girder bridge, upper juncture between the flange and web can be assumed as fixed because concrete deck prevents the rotational displacement of upper flange. In the present study, a series of numerical analyses based on finite element modeling is carried out to investigate the effects of the concrete deck, and the resulting data are quantified in simple equations.

  • PDF

An Experimental Study on Flexural Strength of Inverted T-shaped Composite Beams encased with concrete (매립형 역T형 합성보의 휨내력에 관한 실험적 연구)

  • Jang, Hee-Sung;Jeong, Jae-Hun;Kim, Jin- Moo;Joo, Kyong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.145-152
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section is usually located near the top flange of the steel H-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. However, It is not easy for inverted T-shaped composite beam to construct and to apply continuous beam which has negative bending moment. As a result, it would get more workability and decrease capability of lateral buckling and local buckling, if the bottom flange of inverted T-shaped steel used as a form. Therefore. the objectives of this study are to investigate strength and behaviors of inverted T-shaped composite beam which web is encased by concrete and to grasp bending capacity and efficiency of composite by comparing and analyzing in test piece.

  • PDF

The study for design of the foundation insert of large wind turbine (대형풍력터빈 기초 인서트 설계에 관한 연구)

  • Han, Dong-Young;Choi, Won-Ho;Lee, Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.391-394
    • /
    • 2007
  • The foundation insert is a tubular steel section which is embedded into the concrete of the foundation. The tower base section of the wind turbine is mounted on it. It has a top flange (L type) protruding far enough above the concrete to allow bolts to be inserted from underneath. The load is transmitted to the concrete at the base of the section through a T shaped flange. It has many holes for the reinforcements and the cables. The reinforcements of the concrete foundation run through the insert via a series of holes to bind the inner section to the outer section. Holes are provided for the power and communications cabling. The design follows normal European wind turbine practice, based on GL 2003 and Eurocode regulations.

  • PDF

A Study for Stiffness Improvement Method with Use of Filled Concrete in Continued Steel Box Girder Bridge (강상자형 연속교에서 콘크리트재를 이용한 부모멘트 구간의 강성향상공법)

  • 구민세;이호경
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.69-78
    • /
    • 1999
  • The stiffness of slab concrete section is not considered as effective in the existing method of construction for continued steel box girder bridge. Using lifting system and filled concrete, it is possible to make stiffness of slab concrete section effective and improve stiffness of negative moment section. It was proved that the stress of upper flange in positive moment is significantly lower than case of existing method through the stress comparison. This stress difference made possible to rearrange flange thickness and as the result of this rearrangement, the amount of steel and height of girder can be reduced up to 13.23% and 11.5%.

  • PDF

Ultimate Behavior of Compression Flange Stiffened by Shear Stud on Double Composite Steel Box Girder (이중합성 강박스거더에서 전단연결재에 의해 보강된 압축플랜지의 극한거동에 관한 연구)

  • Lee, Doo Sung;Lee, Sung Chul;Suh, Suk Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.457-463
    • /
    • 2008
  • The longitudinal stiffener performs its role to increase the local buckling strength by making simple support upon compression flange. In the recent researches, it is investigated that compression flange with point supports on certain arrangement reveals the same strength with longitudinal stiffeners. From this results, it is predictable that shear stud could perform the role of longitudinal stiffener if shear stud embedded in concrete satisfies the requirement to point-support under yield stress of the compression flange. In this study, the researches were performed to investigate the optimally required arrangement space of longitudinal point-support for which the shear stud replacing the longitudinal stiffeners and simultaneously determine the required numbers and space of shear stud for completely composite behavior between compression bottom flange and bottom concrete on the double composite girder system.

Effective width of steel-concrete composite beams under negative moments in service stages

  • Zhu, Li;Ma, Qi;Yan, Wu-Tong;Han, Bing;Liu, Wei
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.415-430
    • /
    • 2021
  • The effective flange width was usually introduced into elementary beam theory to consider the shear lag effect in steel-concrete composite beams. Previous studies have primarily focused on the effective width under positive moments and elastic loading, whereas it is still not clear for negative moment cases in the normal service stages. To account for this problem, this paper proposed simplified formulas for the effective flange width and reinforcement stress of composite beams under negative moments in service stages. First, a 10-degree-of-freedom (DOF) fiber beam element considering the shear lag effect and interfacial slip effect was proposed, and a computational procedure was developed in the OpenSees software. The accuracy and applicability of the proposed model were verified through comparisons with experimental results. Second, a method was proposed for determining the effective width of composite beams under negative moments based on reinforcement stress. Employing the proposed model, the simplified formulas were proposed via numerical fitting for cases under uniform loading and centralized loading at the mid-span. Finally, based on the proposed formulas, a simplified calculation method for the reinforcement stress in service stages was established. Comparisons were made between the proposed formulas and design code. The results showed that the design code method greatly underestimated the contribution of concrete under negative moments, leading to notable overestimations in the reinforcement stress and crack width.

Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams

  • Qi, Jingjing;Xie, Zuwei;Cao, Hua;Huang, Zhi;Lv, Weirong;Shi, Weihua
    • Structural Engineering and Mechanics
    • /
    • v.83 no.6
    • /
    • pp.789-798
    • /
    • 2022
  • The stud shear connector is the main force transfer member in the steel-concrete composite member, and the mechanical behavior is very complicated in the concrete. The concrete around the stud is subjected to the pry-out local pressure concentration of the stud, which can easily produce splitting mirco-cracks. In order to solve the problem of pry-out local splitting of stud shear connector, a kind of stud shear connector with constraint measure is proposed in this paper. Through the push-out test, the interface shear behavior of the new stud shear connector between steel and concrete flange plate was studied, and the difference between the new stud shear connector and the traditional stud connector was compared. The results show that the stud shear connector with constraint measure can effectively avoid the adverse effect of local pressure splitting by relying on its own constraint measure. The shear stiffness of the interface between steel and concrete flange plates is greatly improved, which provides a theoretical basis for the design of strong connection coefficient of steel-concrete composite structures.

Development of Improved P.S.C Beam for Railway Bridges (철도교용 개량형 PSC BEAM 개발)

  • Chung, Jee-Seung;Park, Chul;Min, Dae-Hong;Jang, Woo-Sun;Moon, In-Gi;Yoon, Yong-Seok;Yoon, Woo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3142-3146
    • /
    • 2011
  • This paper introduces improved prestressed concrete (PSC) girders for the railway bridges. In order to improve performance of conventional PSC girders, various types of PSC girders are either under development or have already been applied in railway bridges. Incrementally prestressed concrete girder is one of these newly developed girders. According to the design concept, these types of PSC girders have the advantages of requiring less self-weight while having the capability of longer spans. However, the tensional failure of top flange is one of the critical issues at the first prestressing stage. To effectively provide initial section stiffness of PSC girders, concrete block on the top flange is used in this study. The efficiency of the proposed structures, compared with conventional girders and improved ones, is successfully demonstrated in the example.

  • PDF