• 제목/요약/키워드: Concrete block loading test

검색결과 22건 처리시간 0.027초

고강도 콘크리트 기둥단면의 축력-모멘트 강도에 관한 연구 (A Study on Axial Force - Moment Capacity of High-Strength Concrete Tied Column Sections)

  • 박해균;박동규;박영식;손영현;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.300-305
    • /
    • 1996
  • Reinforced concrete column is an effective structural element to take advantage of high strength concrete. This paper presents an experimental and analytical strength of high strength concrete rectangular tied column sections under eccentric loading. The test variables are concrete strength, steel ratios, slenderness and eccentricity. The analytical results of the ACI's rectangular stress block, Zia's modified rectangular stress block, and a trapezoid block are compared with experimentally obtained data. It may be concluded that the trapezoid stress block provided the most reasonable column section capacities for high strength concrete columns.

  • PDF

편심을 받은 고강도 콘크리트 기둥의 출력-모멘트 강도에 관한 실험 및 해석적 연구 (An Experimental and Analytical Study on Axial Force-Moment Capacity of High-Strength Concrete Column under Eccentric Loads)

  • 최창익;손혁수;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.468-474
    • /
    • 1997
  • High strength concrete is a more effective material for columns subject to axial force and moment than for other structural elements. The purpose of this study is to review strength calculation methods for high strength concrete columus by comparison of analytical values and experimental results. The variables of column test under eccentric loading were concrete compressive strength, longitudinal steel ratio, and eccentricity of load. The tied column sections of 120×120mm and 210×210mm were tested and the eccentricity of load varied in the range from 0.16 times to 0.54 times the column depth. The analytical results using the stress-strain relationship to 0.54 times the column depth. The analytical results using the stress-strain relationship as well as the ACI's rectangular block, Zia's modified block, and the trapezoidal block are compared with experimentally obtained data, and discussed in this paper.

  • PDF

고강도 콘크리트 부재의 응력블록에 관한 검토 (The Investigation of Blocks on High Strength Concrete)

  • 신성우
    • 콘크리트학회지
    • /
    • 제2권2호
    • /
    • pp.93-99
    • /
    • 1990
  • 본 연구는 극한강도 이론에 입각한 고강도 콘크리트 부재의 설계를 위한 방법 중 가장 중요한 요소의 하나인 응력-변형도 곡선의 이상화에 관한 연구이다. 이를 위하여 보통강도(280kg/$\textrm{cm}^2$)에서 초고강도(1050kg/$\textrm{cm}^2$)까지의 콘크리트를 사용하여 부재를 제작, 시험하였으며, 기존의 여러 가지 이론과 비교검토를 하였다. 주요 변수는 콘크리트 강도이외에 주근의 양과 전단 보강근의 간격으로 하였다. 실험결과 현재으 ACI Building Code에 규정된 직사각형 응격블록은 고강도 콘크리트에도 사용할 수있음을 알 수 있었다.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

지속하중 재하시 보강토 옹벽의 거동특성 - 축소모형실험 (Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading)

  • 유충식;김선빈;변요셉;김영훈;한대희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.121-130
    • /
    • 2006
  • Despite a number of advantages of reinforced earth walls over conventional concrete retaining walls, there exit concerns over long-term residual deformation when used as part of permanent structures. In view of these concerns, time-dependant deformation characteristics of geosynthetic reinforced modular block walls under sustained loads were investigated using reduced-scale model tests. The results indicated that a sustained load can yield appreciable magnitude of residual deformation, and that the magnitude of residual deformation depends on the loading characteristic as well as reinforcement stiffness.

  • PDF

축소모형실험에 의한 지속하중하에서의 보강토 옹벽의 거동특성 연구 (Behavior of Geosynthetic Reinforced Modular Block Walls under Sustained Loading using Reduced-Scale Model Test)

  • 유충식;김선빈;변요셉;김영훈;한대희
    • 한국지반신소재학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2006
  • 보강토 옹벽이 콘크리트 옹벽에 비해 다양한 이점을 가짐에도 불구하고 영구구조물로서 지속하중이 작용하는 경우에 대해 장기변형이 발생할 소지가 있다는 우려가 있다. 본 논문에서는 이러한 관점에서 축소모형실험을 실시하여 수집된 보강토 옹벽의 장기변형 메카니즘에 대한 내용을 다루었다. 실험결과 지속하중이 작용하는 경우에 있어 장기적으로 잔류변형이 발생할 우려가 있는 것으로 나타났으며 이는 지속하중의 특성과 보강재 강성에 따라 좌우되는 것으로 나타났다.

  • PDF

SY 비탈형 보거푸집의 내하성능에 관한 실험적 연구 (Experimental Study on Loading Capacity of SY Corrugated Steel Form for RC Beam and Girder)

  • 배규웅;부윤섭;황윤국;신상민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.32-39
    • /
    • 2021
  • 최근 공사 기간 단축과 인건비 절감을 위해 철근 콘크리트 보 및 거더용 비탈용 거푸집의 필요성이 많은 구조물에서 강조 되고 있다. 본 연구의 목적은 타설하중, 시공하중, 적재하중에 따른 새로 개발된 SY Beam의 내하성능을 평가하는 것이다. SY Beam의 표준 단면 형상은 MIDAS GEN 프로그램을 통해, 다양한 두께의 강판 데크 구조 모델링을 수행하였다. 해석 모델링 결과, SY Beam의 크기는 높이와 너비가 각각 600 mm와 400 mm로 결정되었다. 총 3 개의 SY Beam에 대해, 실험변수는 강판 데크의 두께로 고려하였으며, 실제 균일 하중 조건을 모사 할 수 있는 모래, 콘크리트 블록, 철근으로 적재한 하중 하에서 수직 및 수평 변위를 측정하는 실험을 수행하였다. 그 결과, 수직 변위는 두께가 증가할수록 감소하는 경향을 보였다. 수평 변위에서는 두께에 따른 추세가 명확하게 관찰되지 않았다. 하중 실험에 대한 평가에서 SY Beam은 작업성과 구조적 안전성을 모두 확보 할 수 있는 것으로 판단된다. 특히, SY Beam (1.2 mm)은 수평 변위가 거의 발생하지 않아 하중지지력이 우수하여, 즉시 상용화를 하여도 경쟁력이 있을 것으로 판단한다.

실험방법에 따른 포장 콘크리트의 피로수명 (Fatigue Lives of Pavement Concrete According to Fatigue Test Methods)

  • 윤경구;김동호;홍창우
    • 한국도로학회논문집
    • /
    • 제5권3호
    • /
    • pp.11-20
    • /
    • 2003
  • 교량, 도로, 공항 및 해양구조물 등은 반복하중을 받게 되는 대표적 토목구조물이다. 특히 공항이나 도로포장체는 휨에 의한 인장에 의해 파괴되기 때문에 사용재료의 특성에 기초한 피로수명의 고찰은 매우 중요하다. 따라서, 이 논문에서는 포장 콘크리트의 피로수명을 주요 실험변수에 따라 실험하고 실험방법에 따라 비교 분석하고자 하였다. 피로실험은 쪼갬인장 피로실험 ($\phi150mm{\times}75mm$)과 휨인장 피로실험 ($150mm{\times}150mm{\times}550mm$) 방법을 적용하여 하중재하 속도(1, 5, 10, 20Hz), 하중재하 형상(사각파, 정현파, 삼각파). 시험체의 습윤조건(건조상태 습윤상태) 및 양생기간(28일, 56일)을 주요 실험변수로 하여 수행하였다. 실험결과 하중재하 속도가 느릴수록 피로수명은 현저히 감소하는 것으로 나타났으며, 하중재하 속도가 빠를수록 피로수명은 증가하는 것으로 나타났다. 하중재하 형상에 따라서는 정현파를 기준하여 사각파에서는 피로수명의 급격한 감소를 나타냈으며 삼각파에서는 피로수명이 증가하는 것으로 나타났다 또한, 시험체의 습윤조건에 따라서는 건조상태에 비하여 습윤상태에서는 피로수명이 감소하였으며, 양생기간에 따라서는 재령 28일에서 56일로 증가함에 따라 피로수명이 증가함을 나타내었다.

  • PDF

진동대 시험을 이용한 중공블록 보강 기초의 내진성능분석 (Analysis on Seismic Resistance Capacity of Hollow Concrete Block Reinforced Foundation Ground by Using Shaking Table Test)

  • 신은철;이연정;양태철
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.85-93
    • /
    • 2021
  • 한반도의 70%는 산지로 구성되어 있으며, 서해와 남해의 수심은 상대적으로 얕은 편이다. 따라서, 공업단지, 주거단지, 항만 및 공항 부지를 위한 대규모 간척사업이 시행되고 있다. 매립지역의 일반적인 문제는 지반이 연약하여 지지력이 부족할 뿐만 아니라 상당한 침하가 발생된다는 것이다. 중공블록은 중·저층 아파트 또는 단층의 공장건물을 건설하기 위해 계획된 느슨한 연약기초 지반보강을 위해 사용된다. 최근 4.0~5.0의 강도를 가진 지진이 서쪽과 남동쪽 해안지역을 따라 발생하고 있다. Lee (2019)는 정적 지지력시험을 통해 얕은 기초보강 중공블록의 장점에 대하여 연구하였다. 이 연구에서 블록 내부에 쇄석으로 채움된 보강된 모래지반의 중공블록 동적거동은 진동대 1000 mm × 1000 mm 시험을 통해 연구하였다. 3가지 지진파인 Ofunato, Hachinohe, Artificial 지진파와 2가지 가속도(0.154g, 0.22g)를 진동대 시험에 적용하였다. 중공블록으로 보강된 지반 위의 구조물 수평변위는 LVDT를 사용하여 측정하였다. 중공블록에 의한 지반보강 효율을 평가하기 위하여 지반의 상대밀도를 45%, 65%, 85%로 각각 구성하였으며, 수평변위를 측정하고 한계수평변위 0.015h(건축물 내진등급기준, 2019)와 비교하였다. 중공블록으로 보강된 모래지반에 대한 진동대 시험 결과에 기반해서 벌집 모양의 중공블록은 블록내부에 쇄석 채움으로서 큰 구속력을 가지며, 중공블록의 내부 및 외부를 따라 발생하는 관입저항력으로 인한 큰 주면마찰력을 갖는 것으로 평가되었다. 이러한 모든 요소들은 진동대 시험 중에 수평변위를 상당이 줄이는 것으로 나타났다. 마지막으로, 중공블록 보강 지반은 지진파와 가속도에 상관없이 중·저층 건물의 얕은기초 보강공법으로 매우 우수함이 입증되었다.