• Title/Summary/Keyword: Concrete Trench

Search Result 14, Processing Time 0.028 seconds

Development of Ultra-Lightweight High Strength Trench Using Lightweight Polymer Concrete

  • Sung, Chan-Yong;Kim, Young-Ik
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.20-26
    • /
    • 2003
  • The ultra-lightweight high strength polymer concrete could be used for the drain structures under severe condition. In this study, materials used were unsaturated polyester resin, heavy calcium carbonate, artificial lightweight coarse aggregate and perlite. In the test results, the unit weight of the ultra-lightweight high strength polymer concrete was 946 kg f/$\textrm{m}^3$ and the compressive strength was appeared in 34.5 MPa. The compressive strength, splitting tensile strength, flexural strength, acid resistance and weather resistance were shown in excellently than that of the normal cement concrete. The draining trench had 1m length, 0.24 m width, 0.02 m thickness and 0.07 m height. The developed trench could be effectively used at the draining structures.

Development of Lightweight Polymer Concrete Using Synthetic Lightweight Aggregate and Application for Bottom Draining Structure (인공경량골재를 활용한 경량 폴리머 콘크리트의 개발 및 바닥배수구조물에의 적용)

  • 성찬용;김영익;윤준노
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.846-851
    • /
    • 2003
  • This study was performed to develop the lightweight polymer concrete using expanded clay and perlite to improve workability, durability and chemical resistance for bottom draining structure under severe condition. This paper was composed of two parts. One is to invest the physical and mechanical properties of lightweight polymer concrete using synthetic lightweight aggregate, the other is to the develop products for bottom draining structure. Physical and mechanical test for lightweight polymer concrete was performed unit weight, compressive and flexural strength, chemical resistance, accelerated weathering test, absorption ratio and optimum mix for lightweight polymer concrete was designed. Also, products for bottom draining structures by optimum mix of lightweight polymer concrete was made draining trench of small size.

  • PDF

Design of the Busan-Geoje Fixed Links Immersed tunnel (기획특집 - 거가대교 침매터널의 설계)

  • Lee, Jung-Sang
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.2
    • /
    • pp.30-33
    • /
    • 2010
  • Immersed tunnel had been a rather new term in Korea before Busan-Geoje fixed link project was started and became known through the media. Although Korean is unfamiliar with the immersed tunnel, this construction method has a long history in the world. Busan-Geoje Fixed Link immersed tunnel consist of 18 elements and each element is approximately 180m long. These tunnel elements are prefabricated of reinforced concrete in a temporary dry dock and are towed to the site and lowered into final position in a dredged trench and are placed on a screeded gravel bed directly without temporary support.

  • PDF

Thermal Resistivity Measurement of Recycled Aggregates and Comparison with Conventional Prediction Model (송배전관로 되메움용 순환골재의 열저항 측정 및 기존 열저항 예측 모델과의 비교)

  • Wi, Jihae;Hong, Sungyun;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.199.1-199.1
    • /
    • 2010
  • Use of recycled aggregates that are constituents of concrete or asphalt-based structures has become popular because the recycling is an eco-friendly way to overcome the depletion of natural aggregates. In order to adopt the recycled aggregates for backfilling a power transmission pipeline trench, their thermal resistivity should be low enough to prevent thermal runaway in the transmission system. In this study, a series of laboratory tests with QTM-500 and KD2 Pro was performed to measure the thermal resistivity of recycled aggregates prepared from various sources. Relationships between the thermal resistivity of recycled aggregates and the water content have been obtained with consideration of compaction effort. Similar to natural soils, the thermal resistivity of the recycled aggregates decreases with increasing the water content. In addition, this study compared the experimental data with conventional prediction models for the thermal resistivity in the literature, which suggests the availability of the recycled aggregates as backfill material substituting for natural aggregates when backfilling the power transmission pipeline trench.

  • PDF

Pilot Test of Biofilter and Vegetation Bed for Contaminated Ditch Treatment at Summer (하절기 오염 소하천 정화를 위한 생물여과조와 식생대의 Pilot Test)

  • Lee, Sang-Hwa;Cho, Moon-Chul;Park, Young-Seek;Moon, Jung-Hyun;Kim, Jwa-Kwan
    • Journal of Wetlands Research
    • /
    • v.1 no.1
    • /
    • pp.7-16
    • /
    • 1999
  • The objective of this study is to recover the contaminated ditch by using a biofilter filled up with waste-concrete media and vegetation bed. Two systems were tested for elimination of organic compounds, turbidity, nitrogen and phosphate. System 1 is three-stage system which consisted of one biofilter and two vegetation bed, system 2 has three-stage system consisted of one biofilter, one vegetation bed (four bed), and one media trench operated in series. In system 1, HRT of biofilter was 4 hour, and Oenanthe javanica was planted in two vegetation bed. In system 2, HRT of biofilter was varied 2 hours and Persicaria chinensis was planted on the top of the biofilter. And Oenanthe javanica, Hydrocharis asiatica, Salvinia natans were planted in four bed of a vegetation bed and the second vegetation bed of system 1 was rebuilt to a media trench bed. The elimination rate of BOD and turbidity was over 90% in both systems. The mean elimination rates 40~50%(system 1), 30~40%(system 2) for T-N and 40~50% (system 1), 30~40%(system 2)for T-P. T-N and T-P elimination performance of system 1 was a little higher(10%) than that of system 2. Results showed that vegetation bed are not efficient in reducing T-N and T-P. It was considered that HRT of vegetation bed of both systems was much lower(1~2hr) than that of conventional system(5~20days).

  • PDF

The reduction of Tire pattern noise by using pitch sequence (피치배열을 이용한 타이어 패턴노이즈 저감)

  • Hwang S.W.;Bang M.J.;Kim S.J.;Cho C.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.611-614
    • /
    • 2005
  • It is well known that tire tread pattern has much influence on the tire pattern noise. The paper describes the method of pattern noise reduction by using the pitch sequence, both on the smooth asphalt roads and on the trenched concrete roads. The noise of tire is classified as either airborne or structure borne noise. Pattern noise through the airborne is considered as a major noise source at high speeds. As block impacting and air pumping by tread patterns are major noise source, tire pattern noise can be greatly influenced by optimal pitch sequence. The goal of this paper is to provide tire engineers with pitch sequence to reduce pattern noise effectively.

  • PDF

Reduction of Railway-induced Vibration using In-filled Trenches with Pipes

  • Hasheminezhad, Araz
    • International Journal of Railway
    • /
    • v.7 no.1
    • /
    • pp.16-23
    • /
    • 2014
  • Reduction in railway-induced vibrations in urban areas is a very challenging task in railway transportation. Many mitigation measures can be considered and applied. Among these, a little attention has been paid to trenches. In this study, a numerical investigation on the effectiveness of in-filled trenches with pipes in reducing railway vibrations due to passing trains is presented. Particularly, a series of two-dimensional dynamic analysis was performed to model the behavior of ballasted railway track under harmonic load with ABAQUS software as a Finite Element method. In so doing, two types of in-filled trenches with pipes with steel and concrete materials have been investigated in this paper. In addition, effectiveness of pipes made of steel and concrete, filled with loose sand and clay in railway-induced vibration reduction has been assessed. The results point out that using in-filled trench with pipes does not effective a lot on railway-induced vibration reduction in comparison to other railway-induced vibration reduction methods. However, in-filled trenches with steel pipes are much more effective than in-filled trenches with concrete pipes. Moreover, filling pipes with loose sand and clay does not have any effect on vibration reduction efficiency of these in-filled trenches.

A design guide to minimize frost heave in unbound pavement layers over box culverts (저토피부 암거상부 포장의 도상피해 예방을 위한 단명설계)

  • Seo, Young-Guk
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.111-121
    • /
    • 2007
  • During the whole month of December in 2005, Korea experienced both heavy snowfall and freezing temperature in southeast regions, which had caused frost related damages to many pavements laid on top of box culverts. In-situ observation revealed that the formation of ice lenses in subgrade and subsequent unbound layers led to upward heaving and transverse cracks in concrete and asphalt pavements. This has affected the long-term performance of pavements, as well as has threatened drivers' safety for a while. Recently, Korea Expressway Corporation has proposed a design guide to better protect newly constructed unbound pavement layers over culverts from frost heave. A trench drainage system has been selected to effectively draw off water and to alleviate pore-water pressure in soils during the coldest season. This paper presents experimental and analytical backgrounds behind this new design guide. Soil specimens retrieved from the sites are tested to quantify clay content and to estimate the permeability of subgrade. A 2-D ground seepage analysis has been conducted to better understand the changes in pore water pressures as a function of grain size. Finally, an optimum size of trench drainage is determined based on numerical analysis and workability in the field.

  • PDF

Properties of Strength and Stress-Strain of Recycled-Plastic Polymer Concrete (폐플라스틱 재활용 폴리머콘크리트의 강도와 응력-변형률 특성)

  • Jo Byung-Wan;Koo Jakap;Park Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.329-334
    • /
    • 2005
  • The use of Polymer Concrete (PC) is growing very rapidly in many structural and construction applications such as box culverts, hazardous waste containers, trench lines, floor drains and the repair and overlay of damaged cement concrete surfaces in pavements, bridges, etc. However, PC has a defect economically because resin which be used for binder is expensive. Therefore the latest research is being progressed to replace existing resin with new resin which can reduce the high cost. Here, Polymer concrete using the recycled PET(polyethylene terephthalate) has some merits such as decrease of environmental destruction, decrease of environmental pollution and development of new construction materials. The variables of this study are amount of resin, curing condition and maximum size of coarse aggregate to find out mechanic properties of this. Stress-strain curve was obtained using MTS equipment by strain control. The results indicated that modulus of elasticity was increased gradually in an ascending branch of curve, as an increase of resin content. Compressive strength was the highest for resin content of $13\%$. And Compressive strength was increased as maximum size of coarse aggregate increases. The strain at maximum stress increases with an increase of resin content and size of coarse aggregate. For the descending branch of stress-strain curve the brittle fracture was decreased when it was cured at the room temperature compared to high temperature.

Effect of Particle Breakage on Compaction and Thermal Resistivity of Concrete-based Recycled Aggregates (콘크리트 재생 순환골재의 파쇄 효과에 따른 다짐 및 열저항 특성 연구)

  • Kang, Sungchul;Kim, Gyeonghun;Wi, Jihae;Ahn, Taebong;Lee, Dae-Soo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.10
    • /
    • pp.17-28
    • /
    • 2015
  • The strict regulations on eco-friendly construction and the significant reduction of natural aggregate resources have raised public concerns on the utilization of recycled aggregates for backfilling a power transmission pipeline trench. In this paper, the particle breakage of concrete-based recycled aggregates and river sand has been experimentally studied during the standard compaction test. The applied compaction energy does not significantly break the river sand particles down, and thus causes no change in the compaction curve, thermal resistivity, and particle gradation characteristics. On the other hand, considerable particle breakage was observed in case of the three recycled aggregates. Such particle breakage leads to enhancing compaction effort, reducing thermal resistivity, and changing particle gradation curve with finer particles that are broken during the first compaction. In addition, particle breakage is more dramatic in lower water contents because pore water may damp down the compaction energy.